4 - Complete line voltage wiring from disconnect switch
near unit to make‐up box.
NOTE - An equipment ground screw is provided. Refer
to unit wiring diagram. Ground unit using a suitable
ground wire.
WARNING
Run 24V Class II wiring only through specified low
voltage opening. Run line voltage wiring only
through specified high voltage opening. Do not
combine voltage in one opening.
CAUTION
Use copper conductors only.
IMPORTANT
If using a programmable thermostat, be sure to use
a type of thermostat that retains its memory in event
of a power loss.
Figure 14
Typical ELO183DH Wiring Diagram