Page 83
TABLE 28
GAS METER CLOCKING CHART
EL296
Unit
Seconds for One Revolution
Natural
LP
1 cu ft
Dial
2 cu ft
Dial
1 cu ft
Dial
2 cu ft
Dial
-045
80
160
200
400
-070
55
110
136
272
-090
41
82
102
204
-110
33
66
82
164
-135
27
54
68
136
Natural-1000 btu/cu ft LP-2500 btu/cu ft
IMPORTANT
For safety, shut unit off and remove manometer as
soon as an accurate reading has been obtained.
Take care to replace pressure tap plug.
G- Proper Combustion
Furnace should operate minimum 15 minutes with correct
manifold pressure and gas flow rate before checking com
-
bustion. See sections E- and F-. Take combustion sample
beyond the flue outlet. TABLE 29 shows acceptable com
-
bustions. The maximum carbon monoxide reading should
not exceed 100 ppm.
TABLE 29
EL296
Mode
l
CO
2
% For Nat
CO
2
% For L.P
Low Fire High Fire Low Fire High Fire
045
5.4 - 6.4
7.5 - 8.5
6.4 - 7.4
8.8 - 9.8
070
5.3 - 6.3
7.4 - 8.4
6.3 - 7.3
8.7 - 9.7
090
5.8 - 6.8
7.6 - 8.6
6.8 - 7.8
8.9 - 9.9
110
6.1 - 7.1
8.0 - 9.0
7.1 - 8.1 9.3 - 10.3
135
6.1 - 7.1
7.8 - 8.8
7.1 - 8.2 9.1 - 10.1
The maximum carbon monoxide reading should not exceed 100ppm.
H- High Altitude
The manifold pressure, gas orifice and pressure switch
may require adjustment or replacement to ensure proper
operation at higher altitudes. See TABLE 30 or TABLE 31
for manifold pressures. See TABLE 32 for gas conversion
and pressure switch kits.
TABLE 30
Manifold and Supply Line Pressure 0-10,000ft.
EL296UH Unit
Gas
Manifold Pressure in. wg.
Supply Line Pressure in. wg.
Low Fire
High Fire
Min
Max
045, 070
-1 through -5 Units
090, 110, 135
-1 through -4 Units
Natural
1.7
3.5
4.5
13.0
LP/Propane
4.5
10.0
11.0
13.0
NOTE -
A natural to L.P. propane gas changeover kit is necessary to convert this unit. Refer to the changeover kit installation instruction for the
conversion procedure.
Содержание EL296UH045XV36B
Страница 89: ...Page 89 VII Wiring and Sequence of Operation Ignition Control 103130 05 EL296 Schematic Diagram...
Страница 90: ...Page 90 Ignition Control 103130 05 and Blower Drive EL296 Units With Blower Drive...
Страница 91: ...Page 91 Ignition Control 107045 01...
Страница 92: ...Page 92 Ignition Control 107045 01 and Blower Drive...