Page 84
TABLE 31
Manifold and Supply Line Pressure 0-10,000ft.
Unit
Gas
Manifold Pressure in. wg.
Supply Line
Pressure in. w.g
0 - 10,000 ft.
0 - 4500 ft
4501 - 5500 ft.
5501 - 6500 ft
6501 - 7500 ft
7501 - 10,000 ft
Low
Fire
High
Fire
Low
Fire
High
Fire
Low
Fire
High
Fire
Low
Fire
High
Fire
Low
Fire
High
Fire
Min
Max
045-6*
070-6*
090-5*
110-5*
135-5*
Natural
1.7
3.5
1.6
3.3
1.5
3.2
1.5
3.1
1.7
3.5
4.5
13.0
LP/
Propane
4.5
10.0
4.2
9.4
4.0
9.1
3.9
8.9
4.5
10.0
11.0
13.0
* And later dash number units
NOTE - A natural to L.P. propane gas changeover kit is necessary to convert this unit. Refer to the changeover kit installation instruction for the
conversion procedure.
TABLE 32
LP/Propane Conversion Kit and Pressure Switch Requirements at Varying Altitudes
Unit
Natural to
LP/Propane
High Altitude
Natural Burner
Orifice Kit
High Altitude LP/
Propane Burner
Orifice Kit
High Altitude Pressure Switch
0 - 7500 ft
7501 - 10,000 ft
7501 - 10,000 ft
4501 - 7500 ft
7501 - 10,000 ft
045
*11K51
73W37
*11K46
14A47
14A50
070-1 through -6
93W80
93W85
-070-7 & later
14A54
14A53
090
14A57
14A54
110
14A46
14A51
135
14A49
14A51
* Conversion requires installation of a gas valve manifold spring which is provided with the gas conversion kit. Pressure switch is factory set. No
adjustment necessary. All models use the factory-installed pressure switch from 0-4500 feet (0-1370 m).