Page 38
BLOWER DATA
EL280UH110P60C PERFORMANCE (Less Filter)
External
Static
Pressure
in. w.g.
Air Volume / Watts at Different Blower Speeds
Bottom Return Air, Side Return Air with Optional Return
Air Base, Return Air from Both Sides or Return Air from
Bottom and One Side.
Single Side Return Air
− Air volumes in
bold
require field
fabricated transition to accommodate 20 x 25 x 1 in. air filter
in order to maintain proper air velocity.
High
Medium-High Medium-Low
Low
High
Medium-High Medium-Low
Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.10
2520 1359 2250 1034 1860
841
1455
654
2605 1454 2160 1060
1740
848
1430
651
0.20
2465 1329 2230 1018 1870
823
1480
647
2505 1401 2150 1018
1785
838
1450
649
0.30
2385 1307 2180
981
1885
809
1540
646
2435 1349 2115
991
1795
818
1485
638
0.40
2295 1256 2105
942
1865
778
1570
638
2350 1308 2070
965
1805
801
1480
631
0.50
2200 1214 2055
909
1845
762
1570
619
2260 1274 2010
929
1785
775
1480
621
0.60
2130 1186 1985
882
1795
741
1550
604
2175 1228 1955
901
1755
752
1490
611
0.70
2015 1150 1890
848
1720
711
1505
580
2085 1186 1850
853
1710
722
1460
594
0.80
1905 1105 1810
815
1675
687
1470
565
1965 1147
1785
818
1640
689
1425
567
NOTES - All air data is measured external to unit without filter (not furnished - field provided)
EL280UH135P60D PERFORMANCE (Less Filter)
External
Static
Pressure
in. w.g.
Air Volume / Watts at Different Blower Speeds
Bottom Return Air, Side Return Air with Optional Return
Air Base, Return Air from Both Sides or Return Air from
Bottom and One Side.
Single Side Return Air
− Air volumes in
bold
require field
fabricated transition to accommodate 20 x 25 x 1 in. air filter
in order to maintain proper air velocity.
High
Medium-High Medium-Low
Low
High
Medium-High Medium-Low
Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.10
2750 1441 2220 1056 1725
825
1395
625
2725 1463 2180 1075
1715
827
1320
624
0.20
2720 1392 2235 1029 1785
810
1445
618
2640 1400 2180 1051
1720
819
1380
626
0.30
2605 1362 2220 1002 1820
800
1460
623
2575 1374 2165 1005
1790
803
1420
622
0.40
2495 1312 2185
968
1845
779
1485
616
2495 1343 2145
988
1775
791
1450
617
0.50
2420 1275 2135
939
1825
767
1505
605
2405 1292 2105
948
1780
777
1470
610
0.60
2335 1234 2080
909
1825
753
1495
593
2305 1257 2045
914
1775
753
1480
593
0.70
2220 1190 1995
864
1760
716
1475
576
2215 1214 1970
884
1740
727
1455
583
0.80
2120 1157 1890
835
1680
686
1435
558
2110 1170 1890
851
1675
699
1430
565
NOTES - All air data is measured external to unit without filter (not furnished - field provided)