Use PVC primer and solvent cement or ABS solvent ce-
ment meeting ASTM specifications, refer to Table 2. As an
alternate, use all purpose cement, to bond ABS, PVC, or
CPVC pipe when using fittings and pipe made of the same
materials. Use transition solvent cement when bonding
ABS to either PVC or CPVC.
Low temperature solvent cement is recommended during
cooler weather. Metal or plastic strapping may be used for
vent pipe hangers. Uniformly apply a liberal coat of PVC
primer for PVC or use a clean dry cloth for ABS to clean
inside socket surface of fitting and male end of pipe to
depth of fitting socket.
Canadian Applications Only - Pipe, fittings, primer and sol
-
vent cement used to vent (exhaust) this appliance must
be certified to ULC S636 and supplied by a single manu
-
facturer as part of an approved vent (exhaust) system. In
addition, the first three feet of vent pipe from the furnace
flue collar must be accessible for inspection.
NOTE - The intake coupling on the furnace is ABS mate-
rial. Use transitional solvent to make connections to PVC
pipe.
NOTE - Vent pipe must be installed with provided vent
adapter. See figure 23.
TABLE 3
OUTDOOR TERMINATION USAGE*
Input Size
Vent Pipe
Dia. in.
STANDARD
CONCENTRIC
Flush
Mount Kit
Wall Kit
Wall Ring
Kit
Field
Fabricated
1-1.2 inch
2 inch
3 inch
2 inch
3 inch
2 inch
71M80
(US)
4
44W92
(CA)
69M29
(US)
4
44W92
(CA)
60L46 (US)
4
44W93 (CA)
51W11
(US)
51W12
(CA)
22G44
(US)
4
30G28
(CA)
44J40
(US)
4
81J20
(CA)
15F74
040
2
3
YES
YES
1
YES
1
YES
5
YES
2
YES
3
3
YES
YES
1
YES
1
YES
5
YES
2
YES
060
2
3
YES
YES
1
YES
1
YES
5
YES
2
YES
3
3
YES
YES
1
YES
1
YES
5
YES
2
YES
080
2
3
YES
YES
YES
5
YES
YES
YES
3
3
YES
YES
YES
5
YES
YES
YES
100
2
YES
YES
YES
5
YES
YES
YES
3
YES
YES
5
YES
YES
YES
NOTE - Standard Terminations do not include any vent pipe or elbows external to the structure. Any vent pipe or elbows external to the structure must be included in total
vent length calculations. See vent length tables.
* Kits must be properly installed according to kit instructions.
1Requires field-provided outdoor 1-1/2” exhaust accelerator.
2Concentric kits 71M80 and 44W92 include 1-1/2” outdoor accelerator, when uses with 040 and 060 input models.
3 Flush mount kits 51W11 and 51W12 includes 1-1/2 in. outdoor exhaust accelerator, required when used with 040, 060 and 080 input models.
4 Termination kits 30G28, 44W92, 4493 and 81J20 are certified to ULC S636 for use in Canada only.
5 See table 8 for vent accelerator requirements.