EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 40
AHRI SYSTEM MATCHES - ALL REGIONS
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER
EER
Coil or
Air Handler
Furnace
AHRI
Reference
EL16XC1-030-230A
TXV
29,000
14.50
12.20
CX35-48C
8810863
EL16XC1-036-230A
RFC
34,400
14.00
12.20
C33-38A
8811823
EL16XC1-036-230A
RFC
34,400
14.00
12.20
C33-38B
8811839
EL16XC1-036-230A
RFC
34,600
14.00
12.20
C33-43
8811869
EL16XC1-036-230A
RFC
34,800
14.25
12.20
C33-49
8811931
EL16XC1-036-230A
RFC
34,400
14.00
12.20
C33-50/60C
8811951
EL16XC1-036-230A
RFC
34,800
14.25
12.20
C35-49C
8812072
EL16XC1-036-230A
RFC
34,400
14.00
12.20
C35-50/60C
8812092
EL16XC1-036-230A
RFC
34,400
14.00
12.20
CH33-31B
8812176
EL16XC1-036-230A
RFC
35,000
14.50
12.20
CH33-43B
8812242
EL16XC1-036-230A
RFC
34,400
14.00
12.20
CH33-44/48B
8812276
EL16XC1-036-230A
RFC
34,400
14.00
12.20
CH33-48
8812296
EL16XC1-036-230A
RFC
35,000
14.50
12.20
CH33-49
8812316
EL16XC1-036-230A
RFC
34,800
14.25
12.20
CH33-50/60C
8812336
EL16XC1-036-230A
TXV
34,600
15.10
12.50
C33-31A
EL180UH045E36A
8811768
EL16XC1-036-230A
TXV
34,600
15.10
12.50
C33-31A
EL180UH045XE36A
8811769
EL16XC1-036-230A
TXV
34,800
15.10
12.50
C33-31A
SL280UH070V36A
8811770
EL16XC1-036-230A
TXV
34,800
15.10
12.50
C33-31A
SL280UH070XV36A
8811771
EL16XC1-036-230A
TXV
34,400
14.25
12.20
C33-31A
8811772
EL16XC1-036-230A
TXV
34,800
15.10
12.50
C33-31B
EL180UH070E36B
8811773
EL16XC1-036-230A
TXV
34,800
15.10
12.50
C33-31B
EL180UH070XE36B
8811774
EL16XC1-036-230A
TXV
34,800
15.50
12.50
C33-31B
EL180UH090E48B
8811775
EL16XC1-036-230A
TXV
34,800
15.50
12.50
C33-31B
EL180UH090XE48B
8811776
EL16XC1-036-230A
TXV
34,400
14.50
12.20
C33-31B
EL195UH045XE36B
8811777
EL16XC1-036-230A
TXV
34,400
15.10
12.50
C33-31B
EL195UH070XE36B
8811778
EL16XC1-036-230A
TXV
34,400
14.50
12.20
C33-31B
EL296UH045XE36B
8811779
EL16XC1-036-230A
TXV
34,600
15.10
12.50
C33-31B
EL296UH045XV36B
8811780
EL16XC1-036-230A
TXV
34,400
15.10
12.50
C33-31B
EL296UH070XE36B
8811781
EL16XC1-036-230A
TXV
34,800
15.10
12.50
C33-31B
EL296UH070XV36B
8811782
EL16XC1-036-230A
TXV
34,800
15.50
13.00
C33-31B
SL280UH090V36B
8811783
EL16XC1-036-230A
TXV
34,800
15.50
12.50
C33-31B
SL280UH090V48B
8811784
EL16XC1-036-230A
TXV
34,800
15.50
12.50
C33-31B
SL280UH090XV48B
8811785
EL16XC1-036-230A
TXV
34,800
15.10
12.50
C33-31B
SLP98UH070XV36B
8811786
EL16XC1-036-230A
TXV
34,400
14.25
12.20
C33-31B
8811787
EL16XC1-036-230A
TXV
33,600
14.50
12.20
C33-36A
EL180UH045E36A
8811788
EL16XC1-036-230A
TXV
33,600
14.50
12.20
C33-36A
EL180UH045XE36A
8811789
EL16XC1-036-230A
TXV
33,800
14.50
12.50
C33-36A
SL280UH070V36A
8811790
EL16XC1-036-230A
TXV
33,800
14.50
12.50
C33-36A
SL280UH070XV36A
8811791
EL16XC1-036-230A
TXV
33,800
15.50
12.50
C33-36B
EL180UH070E36B
8811792
EL16XC1-036-230A
TXV
33,800
15.50
12.50
C33-36B
EL180UH070XE36B
8811793
EL16XC1-036-230A
TXV
33,800
15.10
12.50
C33-36B
EL180UH090E48B
8811794
EL16XC1-036-230A
TXV
33,800
15.10
12.50
C33-36B
EL180UH090XE48B
8811795
EL16XC1-036-230A
TXV
33,400
14.50
12.50
C33-36B
EL195UH045XE36B
8811796
EL16XC1-036-230A
TXV
33,600
14.50
12.20
C33-36B
EL195UH070XE36B
8811797
EL16XC1-036-230A
TXV
33,400
14.50
12.50
C33-36B
EL296UH045XE36B
8811798
EL16XC1-036-230A
TXV
33,800
14.50
12.50
C33-36B
EL296UH045XV36B
8811799
EL16XC1-036-230A
TXV
33,600
14.50
12.20
C33-36B
EL296UH070XE36B
8811800
EL16XC1-036-230A
TXV
33,800
14.50
12.50
C33-36B
EL296UH070XV36B
8811801
EL16XC1-036-230A
TXV
34,000
15.50
12.50
C33-36B
SL280UH090V36B
8811802
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.