background image

16

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

See Below.

Disconnect the two black wires from the wire nuts. Test switch(s) for
continuity with a multimeter. If continuity is not indicated, switch(s) is
defective and must be replaced.

Note: 

Before replacing “OFF/ON” switch, be sure to check wiring for loose

connections or broken wires and repair as needed.

Check main burner orifice(s) for stoppage. Clean or replace.

Check vent system for obstructions.

A.

Faulty Valve System.

B.

“OFF/ON” or wall switch
defective.

A.

Burner orifice plugged.

B.

Obstructed vent system.

1.

Burner will not light.

2.

Burners come “ON” but
go “OFF.”

N

ote:

 

Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in

the “ON” position.

Important: 

Valve system troubleshooting should only be accomplished by a qualified service technician.

• Turn Off Gas Supply
• Assure Valve Switch Is In ON Position
• Disconnect Control Harness
• Set Thermostat To Call For Heat

• Check For Proper Voltage At Control Harness
  (See Insert A).  Voltage Should Be 24V
  Between Thermostat Or Pressure Switch
  And 24V Common And 24V Hot.

• Line Voltage Power
• Low Voltage Transformer
• Limit Controller
• Thermostat
• Wiring

2

CHECK

START

2

1

NO

• Plug Control Harness Into Valve.  Wait For
   Internal Check Delay.

YES

• Igniter Warms Up And Glows Red.

• With Pilot Burner Cable Connected, Measure
   Voltage At Valve HSI Element Output.  24V
   Nominal.  (See Insert B)

NO

• Replace Igniter/Flame Rod Assembly.

YES

• Replace Valve.

NO

• Turn On Gas Supply.    • Pilot Burner Lights.

• Check That Pilot Gas Is Flowing.  Wait To
   Assure Plot Gas Tubing Is Purged.  Recycle
   Call For Heat If Necessary.

NO

YES

NO

YES

YES

1

• Measure Voltage Between 24V Hot And 24V Common
   Leads To Valve Control.  Must Measure At Least 19.5
   VAC With Igniter Powered (See Insert A).  To Identify
    Proper Lead, This Check Must Be Done With The
    Valve Control Connected And Igniter Powered.

• Check Transformer And
   Line Volt Supply.

NO

• Replace Pilot Assembly.

YES

• Check That Pilot Flame Makes Good Contact With
   Pilot Burner Flame Rod.
• Check For Good Electrical Connection Through The
   Pilot Tubing.
• If Both Of The Above Are Good, Replace Igniter/Flame
   Rod Assembly.

• Cycle Thermostat Off And Back On.

YES

• Main Valve Opens And Main Burner Lights.

NO

YES

• System Is Okay.

YES

• Main Burner Lights.

NO

2

1

Igniter Will Cycle Off And Back On Once During
The 90 Second Ignition Trial.  All Voltage
Measurements Must Be Taken While The Igniter
Is Powered.

When Measured Voltage At Connections, Use
Care To Assure Terminals Are Not Damaged.

• Replace Valve.

• Replace Valve.

24 Volt Hot

End View Of
Control Harness
Connector

24 Volt
Common

24 Volt
Switched

Check For Damaged Or Missing Terminals
In Connector

Insert A

Igniter Terminals

Insert B

Содержание ED4540CNE-2

Страница 1: ...ntreposerniutiliser d essencenid autrevapeursouliquidesinflammables dans le voisinage de cet appareil ou de tout autre appareil POUR VOTRE S CURIT Que faire si vous sentez une odiur de gaz Ne pas tent...

Страница 2: ...ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY ORPROPERTYDAMAGE REFERTOTHIS MANUAL FOR ASSISTANCE OR ADDI TIONAL INFORMATION CONSULT A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUP...

Страница 3: ...valve and its related controls is attainable Operation of millivolt and electronic gas control systems are different Before light ing and operating your appliance determine if you have a millivolt or...

Страница 4: ...service techni cian Proper maintenance and use will require more frequent less extensive inspections and servicing by the homeowner Generally annual inspections should be per formedbyaqualifiedservice...

Страница 5: ...ndburner area RefertoFigure7onpage7andverifytheflame pattern and height displayed by the appliance conforms to the picture Flames must not impinge on the logs Refer toFigure8 SIT orFigure9 Honeywell o...

Страница 6: ...to operate for at least 15minutes Observetheflamecontinuously If it appears weak or sooty as previously de scribed adjust the air shutter by pushing or pulling on the adjustment rod until the flame a...

Страница 7: ...G LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF HANDLE ONLY WHEN LOGS ARE COOL TURN OFF ALL ELECTRICITY TO THE APPLIANCE BEFORE YOU INSTALL GRATE AND LOGS WARNING...

Страница 8: ...any of the original wire as supplied must be replaced 1 it must be replaced with Type AWM 200 C 18 GA wire 2 120V 60Hz Less than 3 amps BK Junction Box Transf 120 V 24 V Factory Wired Field Wired BL E...

Страница 9: ...ll and do not requirehardwaretoattachthemtothestandard door frame These kits can be retrofitted to previously installed 4540 Series appliances The decorative arch kits can not be used in conjunction w...

Страница 10: ...sh 88L34 LVR45BS Brass Finish 88L30 LVR45PB 2 Brushed Stainless Finish Hood Kit 88L51 EB45BS Brass Finish Hood Kit 96K69 EB45PB Brass Hood Kits Attractive hoods are available in two styles to be used...

Страница 11: ...ove on this page If you do not smell gas go to the next step 7 Push in gas control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold in Immediately light the...

Страница 12: ...ournez le dans le sens des aiguilles d une montre jusqu la position d arr t OFF Ne forcez pas le bouton 5 Fermez le compartiment de contr le du bas 8 Enfoncez le bouton de r glage jusqu au fond et gar...

Страница 13: ...use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which ha...

Страница 14: ...ire inspecter l appareil et remplacer toute pi ce du syst me de r glage ou commande du gaz qui a t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur...

Страница 15: ...a qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 9 on page 7 Check burner orifice for stoppage and remove Checkthermopilewithmillivo...

Страница 16: ...2 1 NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected Measure Voltage At Valve HSI Element Output 24V Nominal See In...

Страница 17: ...P y t Q y l b m e s s A e c a l p e r i F s a G 1 d o o H Y D 1 4 9 1 9 B L 1 Y D 1 4 9 1 9 B L 1 2 r e v u o L D 2 4 4 2 9 B L 5 D 2 4 4 2 9 B L 5 3 e s a B r e v u o L D 7 4 4 2 9 B L 1 D 7 4 4 2 9...

Страница 18: ...18 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 4 9 14 7 31 30 21 20 15 8 33 23 22 24 32 26 25 11 16 13 10 12 2 1 5 6 2 3 17 18 19...

Страница 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE...

Страница 20: ...REV A 04 2001 LENNOX reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distr...

Отзывы: