background image

INSTALLATION 

 

PAGE 9 

POWER CORD CHANGEOVER 

 

DANGER: Risk of electrical shock. Disconnect 
power before servicing appliance. Do not route 
power cord under or in front of appliance.

 

 

To change the power cord from one side of insert to the 
other, perform the following steps: 
1.  Ensure power cord in NOT plugged in. 
2.  Remove the louver blower panels on each side of 

fuel door as follows. Each panel is held in place by 
two ¼” (7 mm) head screws.  Using a ¼” (7 mm) 
socket or nut driver, remove the screws 

3.  Remove panels by pulling them outward slightly then 

forward.  

4.  Locate terminal block on right side of appliance. 

Write down the locations where the black, white and 
green leads from the power cord are attached to the 
terminal block. Disconnect these three wires then re-
install them onto the terminal block on the left side of 
appliance in the same corresponding positions (as 
you had written down). 

5. Reinstall 

panels. 

 
BAFFLE PLATE 

This appliance has a very heavy (60 lbs [27 kg]) 3/8" (9.5 
mm) thick steel baffle that is installed directly above the 
secondary air tubes in the firebox. To inhibit the baffle 
plate from shifting during shipment, a packing block is 
installed at the factory (see illustration below). The pack-
ing block needs to be removed prior to burning your in-
sert. During installation, the baffle may slide forward, and 
must be repositioned (pushed to the back) in order for 
the insert to operate properly. When in its proper posi-
tion, the rear flange of the baffle plate should be flush to 
the back wall of the firebox. 
 

 

MARBLE

 

Marble is a natural product and therefore each piece will 
have its own unique character. Marble can be scratched 
so care should be taken to avoid putting heavy or rough 
objects (trivet / steamers) on the surface. Do not install 
the marble before curing the paint. 
 
The ceramic fiber blanket and cerawool strips provided 
with appliance must be placed under the marble to insu-
late it from the high temperatures on top of the firebox. 
Do not place the marble directly on the top metal surface 
of the stove or it will crack. 
 

 

 

INSTALLATION STEPS 

1. Remove all ashes from the fireplace. 
2. Remove all materials inside the insert and set them aside. 
3. Remove the three-piece surround assembly (face shield) 

and attach insulation material provided using a nonflamma-
ble adhesive (i.e. RTV Silicone, rated 570

°

 F). 

4. Use a large piece of cardboard or other protective material 

and place it in front of the fireplace to protect floor or carpet 
during installation. 

5. Remove the insert from its wood pallet by removing the 

screws. 

6. Prepare chimney connection system as specified for ma-

sonry or zero clearance fireplaces. 

7. Set the insert on the protective cardboard laid out in front of 

the fireplace centered in front of the fireplace opening.  

8. (Masonry Fireplace) Slide insert into the fireplace far enough 

to attach the starter pipe or positive flue connection (a mini-
mum of a 6" (152 mm) starter pipe extending past the 
header is required). See 

*

 note, page 11. 

9. (Factory Built Fireplace – USA only) Slide insert into the fire-

place far enough to attach connector to flue outlet. See

  *

 

note, page 11. 

Содержание EARTH STOVE 2800HT

Страница 1: ...ODEL 2800HT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED WOOD BURNING FIREPLACE INSERT THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE IN...

Страница 2: ...er fluid or similar liq uids to start or freshen up a fire in this heater Keep all such liquids well away from the heater while it is in use 12 DO NOT OVERFIRE If heater or chimney con nector glows yo...

Страница 3: ...ne Insulation pad and strips Place pad under top marble and strips under ash lip marble USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay speci...

Страница 4: ...thin the same room you must follow the requirements of your local code Check with your local building department for requirements in your area IMPORTANT THIS APPLIANCE IS NOT AP PROVED FOR INSTALLATIO...

Страница 5: ...PA 211 92 draft 1 7 A chimney or vent shall be so designed and con structed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere The venting system shall...

Страница 6: ...not alter the integrity or outer shell of the pre engineered fireplace cabinet in any way Venting Requirements for factory built fireplace The fireplace damper must be secured in the open po sition T...

Страница 7: ...nry fireplace only installation into a factory built fireplace is not approved The fireplace damper must be secured in the open position The fireplace in sert must be installed with a continuous chimn...

Страница 8: ...th into fireplace 15 3 4 400 mm FACTORY BUILT FIREPLACE REQUIREMENTS Note In Canada installation into a Factory Built Fireplace is not approved When installing the 2800HT into a high dome or low profi...

Страница 9: ...of the baffle plate should be flush to the back wall of the firebox MARBLE Marble is a natural product and therefore each piece will have its own unique character Marble can be scratched so care shoul...

Страница 10: ...e hearth leveling bolts will need to be installed not included with the hardware Use a 3 8 10 mm bolt with 2 nuts The bolt length should be at least 1 25 4 mm longer than needed Locate the leveling bo...

Страница 11: ...ides of the flue outlet Use self tapping screws to secure in place Cut a 13 mm height and 19 mm width notch in the front of connector pipe liner or adapter that will attach to flue outlet Install conn...

Страница 12: ...e blowers will turn on when the insert is hot and turn off when the insert is cool See Care and Operation Section Blower System on page 16 Blower System Controls Located on right side of door at botto...

Страница 13: ...may get dirty A short hot fire 15 20 minutes will help clean off much of the normal buildup see Troubleshooting pages 19 20 A commercial glass cleaner designed for fireplace inserts is recommended for...

Страница 14: ...AINTAIN A FIRE 1 Set the primary air control to the open position push in 2 Set the start up air control to the open position pull out 3 Build a fire directly on the firebrick covering the bot tom of...

Страница 15: ...ctrical cord that must be electrically grounded per lo cal codes or NEC ANSI NFPA 70 latest edi tion Do not route the power cord under or in front of the appliance Blower System Controls Located on ri...

Страница 16: ...s Logs that are 5 127 mm diameter across or larger should be split in half three pieces if over 8 inches 203 mm and four pieces when over a foot across If the tree fell 2 to 4 years ago it still needs...

Страница 17: ...nstall door CLEANING BLOWERS The blowers require inspection and cleaning annually to remove lint dust etc If there are pets in the dwelling the blowers should be cleaned at least twice a year To ac ce...

Страница 18: ...agonally into lower firebox Remove baffle plate through door opening diagonally WARNING DO NOT OPERATE THE INSERT WITH OUT THE BAFFLE PLATE PROPERLY INSTALLED THIS WILL VOID WARRANTY In the event of a...

Страница 19: ...ceiling fan with a winter summer switch 4 The area to heat is too large square foot heating estimates are based on average climates and home design 5 There is an obstruction in the chimney 6 The chim...

Страница 20: ...re this may result in improper operation of appliance i e wont maintain fire unless fuel door is left open See below Overfiring Caused From Improper Op eration on this page Overfiring Caused From Impr...

Страница 21: ...e 8 10 hours Fuel capacity 50 60 lbs 23 27 kg Firebox size cubic feet 2 9 c f 884 cubic mm Maximum Burn Rate 74 100 BTU EPA BTU Range 11 500 46 700 BTU EPA Efficiency 63 Emissions Rate grams hour 4 5...

Страница 22: ...28 Rheostat W Connectors Knob Not Included p n 10050087 10050087 Rheostat Knob 410 270 Rocker Switch On Off Switch 11565 Disc Fan F110 20F 60T12 410 265 Terminal Block Small 410 260 Terminal Block Lar...

Страница 23: ...nt parts contact Lennox Hearth Products 1110 West Taft Avenue Orange CA 92865 PAGE 23 Part No Description MS2805 Marble Set Green Also requires 1 each 1053 4 each 1051 1053 Cerawool Pad For Marble req...

Страница 24: ...COMPONENT DIAGRAMS Model 2800HT PAGE 24 FIREBRICK 1 THICK AIR CONTROLS FIREBOX PARTS DOOR ASSEMBLY HANDLE ASSEMBLY...

Страница 25: ...be handled using an off set adapter it aligns starter pipe with flue Actual Appearance Masonry Fireplace Kit This header insulation kit is required when installing the insert into a masonry fireplace...

Страница 26: ...SAFETY LISTING LABEL PAGE 26...

Страница 27: ...EPA LABEL PAGE 27...

Страница 28: ...28 OWNERSHIP RECORDS Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Descrip...

Страница 29: ...1110 West Taft Avenue Orange CA 92865...

Отзывы: