CARE AND OPERATION 

 

PAGE 14 

AIR DRAFT CONTROLS

 

This appliance has two combustion air controls located 
under the hearth extension. The control on the left is the 
Start-Up Air Control. The control in the center is the Pri-
mary Air Control. 
 

 

 
Start-Up Air Control

 

To provide sufficient combustion air to achieve a clean 
burn as quickly as possible, the 2800HT supplements its 
primary air with a separate "Start-Up" supply. This con-
trol should be used only when starting a fire or when 
refueling. The start up air enters the stove at the rear of 
the firebox and is controlled by the Start-Up Air Control 
rod on the left. 
 
From a cold start, approximately 10 minutes in the open 
position is all that is required to achieve a stable burn. 

 
CAUTION:  OPERATION OF THE APPLIANCE WITH 
THE START-UP AIR CONTROL IN THE "OPEN" POSI-
TION (PULLED OUT) FOR EXTENDED PERIODS, 
WASTES FUEL AND CAN CAUSE DANGEROUS 
OVERFIRING CONDITIONS.

 

 
PRIMARY AIR CONTROL

 

Once the fuel load is well ignited, the Primary Air Control is 
all that is needed to vary the burn rate in the insert. Push in 
for a high burn rate; pull out for a slower burn rate. 
 

USE CONTROL SETTINGS THAT WORK FOR YOU 

The fuel, the amount of heat you want, the type of instal-
lation you have and how long you wish the fire to burn 
are all variables that will affect the control setting.  The 
same control settings in a variety of installations will pro-
duce different results. 
 
Familiarize yourself with your fireplace insert by trying 
different settings so you can learn how much heat to 
expect and how long the fire will burn. It may take a 
week or two to learn but your patience will be rewarded 
by the warmth and pleasant satisfaction that only a 
wood fire can provide. 

HOW TO START AND MAINTAIN A FIRE

 

1.  Set the primary air control to the open position (push 

in).  

2.  Set the start-up air control to the open position (pull 

out).  

3.  Build a fire directly on the firebrick covering the bot-

tom of the stove. 
a. Place two or three loosely crumpled sheets of 

newspaper in the insert firebox. 

b. Add a small amount of dry kindling randomly on 

the top of the newspaper. 

c.  Place one or two more loosely crumpled newspa-

pers on top of the kindling and light the bottom 
paper first, then light the top paper. 

4.  Once the kindling is ignited and burning on its own, 

close the fuel door. The upper fire should help pre-
heat the chimney and create an effective draft while 
the lower fire ignites the kindling. 

5. When the kindling is burning well, add increasingly 

larger pieces of wood until the fire is actively burning 
and a coal bed develops.  By keeping both air con-
trols open for approximately 10 minutes, the fuel and 
the insert will quickly come up to ideal operating tem-
peratures producing the highest combustion effi-
ciency and least emissions. 

6.  Close the start-up air control (push in). 
 

  CAUTION:  THIS CONTROL SHOULD ONLY BE 

USED DURING START UP AND REFUELING. 

 
7.  Set the primary air control to the desired setting. The 

insert will now provide clean, efficient and safe heat 
for your home. 

 

REFUELING 

To refuel the insert, first move the primary air control to 
high. Let the fire "liven up" for about one minute. Open 
the fuel door about 1/2" (1 cm) and hold in this position 
about 30 seconds or until insert is drafting well. Open 
the door and add wood. If the fire or coal bed is almost 
depleted and a full load of cordwood is added, it may be 
necessary to open the start-up air control to re-establish 
a lively fire. The use of start-up air should only be used 
for a short period.  
 
NOTE:  After refueling and the wood is burning at a 
brisk rate, reset the primary air control to the desired 
position and close the start-up air control. 

Содержание EARTH STOVE 2800HT

Страница 1: ...ODEL 2800HT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED WOOD BURNING FIREPLACE INSERT THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE IN...

Страница 2: ...er fluid or similar liq uids to start or freshen up a fire in this heater Keep all such liquids well away from the heater while it is in use 12 DO NOT OVERFIRE If heater or chimney con nector glows yo...

Страница 3: ...ne Insulation pad and strips Place pad under top marble and strips under ash lip marble USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay speci...

Страница 4: ...thin the same room you must follow the requirements of your local code Check with your local building department for requirements in your area IMPORTANT THIS APPLIANCE IS NOT AP PROVED FOR INSTALLATIO...

Страница 5: ...PA 211 92 draft 1 7 A chimney or vent shall be so designed and con structed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere The venting system shall...

Страница 6: ...not alter the integrity or outer shell of the pre engineered fireplace cabinet in any way Venting Requirements for factory built fireplace The fireplace damper must be secured in the open po sition T...

Страница 7: ...nry fireplace only installation into a factory built fireplace is not approved The fireplace damper must be secured in the open position The fireplace in sert must be installed with a continuous chimn...

Страница 8: ...th into fireplace 15 3 4 400 mm FACTORY BUILT FIREPLACE REQUIREMENTS Note In Canada installation into a Factory Built Fireplace is not approved When installing the 2800HT into a high dome or low profi...

Страница 9: ...of the baffle plate should be flush to the back wall of the firebox MARBLE Marble is a natural product and therefore each piece will have its own unique character Marble can be scratched so care shoul...

Страница 10: ...e hearth leveling bolts will need to be installed not included with the hardware Use a 3 8 10 mm bolt with 2 nuts The bolt length should be at least 1 25 4 mm longer than needed Locate the leveling bo...

Страница 11: ...ides of the flue outlet Use self tapping screws to secure in place Cut a 13 mm height and 19 mm width notch in the front of connector pipe liner or adapter that will attach to flue outlet Install conn...

Страница 12: ...e blowers will turn on when the insert is hot and turn off when the insert is cool See Care and Operation Section Blower System on page 16 Blower System Controls Located on right side of door at botto...

Страница 13: ...may get dirty A short hot fire 15 20 minutes will help clean off much of the normal buildup see Troubleshooting pages 19 20 A commercial glass cleaner designed for fireplace inserts is recommended for...

Страница 14: ...AINTAIN A FIRE 1 Set the primary air control to the open position push in 2 Set the start up air control to the open position pull out 3 Build a fire directly on the firebrick covering the bot tom of...

Страница 15: ...ctrical cord that must be electrically grounded per lo cal codes or NEC ANSI NFPA 70 latest edi tion Do not route the power cord under or in front of the appliance Blower System Controls Located on ri...

Страница 16: ...s Logs that are 5 127 mm diameter across or larger should be split in half three pieces if over 8 inches 203 mm and four pieces when over a foot across If the tree fell 2 to 4 years ago it still needs...

Страница 17: ...nstall door CLEANING BLOWERS The blowers require inspection and cleaning annually to remove lint dust etc If there are pets in the dwelling the blowers should be cleaned at least twice a year To ac ce...

Страница 18: ...agonally into lower firebox Remove baffle plate through door opening diagonally WARNING DO NOT OPERATE THE INSERT WITH OUT THE BAFFLE PLATE PROPERLY INSTALLED THIS WILL VOID WARRANTY In the event of a...

Страница 19: ...ceiling fan with a winter summer switch 4 The area to heat is too large square foot heating estimates are based on average climates and home design 5 There is an obstruction in the chimney 6 The chim...

Страница 20: ...re this may result in improper operation of appliance i e wont maintain fire unless fuel door is left open See below Overfiring Caused From Improper Op eration on this page Overfiring Caused From Impr...

Страница 21: ...e 8 10 hours Fuel capacity 50 60 lbs 23 27 kg Firebox size cubic feet 2 9 c f 884 cubic mm Maximum Burn Rate 74 100 BTU EPA BTU Range 11 500 46 700 BTU EPA Efficiency 63 Emissions Rate grams hour 4 5...

Страница 22: ...28 Rheostat W Connectors Knob Not Included p n 10050087 10050087 Rheostat Knob 410 270 Rocker Switch On Off Switch 11565 Disc Fan F110 20F 60T12 410 265 Terminal Block Small 410 260 Terminal Block Lar...

Страница 23: ...nt parts contact Lennox Hearth Products 1110 West Taft Avenue Orange CA 92865 PAGE 23 Part No Description MS2805 Marble Set Green Also requires 1 each 1053 4 each 1051 1053 Cerawool Pad For Marble req...

Страница 24: ...COMPONENT DIAGRAMS Model 2800HT PAGE 24 FIREBRICK 1 THICK AIR CONTROLS FIREBOX PARTS DOOR ASSEMBLY HANDLE ASSEMBLY...

Страница 25: ...be handled using an off set adapter it aligns starter pipe with flue Actual Appearance Masonry Fireplace Kit This header insulation kit is required when installing the insert into a masonry fireplace...

Страница 26: ...SAFETY LISTING LABEL PAGE 26...

Страница 27: ...EPA LABEL PAGE 27...

Страница 28: ...28 OWNERSHIP RECORDS Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Descrip...

Страница 29: ...1110 West Taft Avenue Orange CA 92865...

Отзывы: