background image

 

HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS

DIRECT-VENT GAS FIREPLACE HEATERS

OTL Report No. 116-F-31-5

A French manual is available upon request. Order P/N 875,028CF

Ce manuel d’installation est disponible en francais, simplement en 
faire la demande. Numéro de la pièce 875,028CF

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

Millivolt Models 

Electronic Models

P/N 875,028M  REV. C 06/2005

FOR YOUR SAFETY:  Do not store or use gasoline 
or other fl ammables or liquids in the vicinity of 
this or any other appliance.

FOR YOUR SAFETY: What to do if you smell gas:

•  DO NOT light any appliance.
•  DO NOT touch any electrical switches.
•  Do not use any phone in your building.
•  Immediately call your gas supplier from a
    neighbor’s phone. Follow your gas suppliers 
 instructions.
•  If your gas supplier cannot be reached, call
  the fi re department.

Installation and service must be performed by 
a qualifi ed installer, service agency or the gas 
supplier.

MODELS

WARNING:  IF THE INFORMATION IN THIS MANUAL 
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE, 
PERSONAL INJURY OR LOSS OF LIFE.

LMDV-3530 MODEL SHOWN

Listing Agency

DIRECT VENT MERIT

®

 

LMDV-33/35/40 SERIES

LMDVT-3328CNM
LMDVT-3328CPM
LMDVR-3328CNM
LMDVR-3328CPM
LMDV-3530CNM
LMDV-3530CPM
LMDV-4035CNM
LMDV-4035CPM

LMDVT-3328CNE
LMDVR-3328CNE
LMDV-3530CNE
LMDV-4035CNE

Содержание DIRECT VENT MERIT LMDV-33 SERIES

Страница 1: ...O NOT light any appliance DO NOT touch any electrical switches Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow your gas suppliers instructions I...

Страница 2: ...ns Millivolt Page 17 Lighting Instructions Electronic Page 18 Maintenance Schedule Page 19 Troubleshooting Guide Millivolt Page 20 Troubleshooting Guide Electronic Page 20 Replacement Parts List Page...

Страница 3: ...nents Any modification or alteration may void the warranty certification and listings of this unit Theseappliancesandtheirindividualshut off valves must be disconnected from the gas supply piping syst...

Страница 4: ...down until it locks in place Figure 1 OPENING CONTROL COMPARTMENT DOOR Operation of millivolt and electronic gas con trol systems are different Before lighting and operatingyourappliancedetermineifyou...

Страница 5: ...ons Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve 3 Keep the lower control compartment clean by vacuuming o...

Страница 6: ...ed replacement use only the proper replacement logs from manufacturer see Pages 22 23 for ordering information Re Install Embers Logs and Vermiculite Carefully follow placement instructions on Pages 8...

Страница 7: ...front of the appliance 4 Swing the bottom of the door out and raise it slightly to lift the top flange of the door frame away from the appliance Installing Glass Enclosure Panels see Figure 6 1 Visua...

Страница 8: ...re 8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested...

Страница 9: ...VolcanicStoneandLogsintheorder shown here 1 through 6 and per the instructions onPage8 A E B C D Vermiculite Volcanic Stone Embers DO NOT PLACE EMBERS OVER GAS SLOTS 1 2 3 4 5 6 The2notchesonlogbottom...

Страница 10: ...rrespond to photos InstalltheEmbers Vermiculite VolcanicStoneandLogsintheorder shownhere 1through6 andper theinstructionsonPage8 D C E A B 1 2 3 4 5 6 Vermiculite Volcanic Stone DONOTPLACEEMBERSOVERGA...

Страница 11: ...hanorangebodythatdoes not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning t...

Страница 12: ...position until the proper flame appearance is achieved 4 Leave the control knob off pilot on in the ON position and the burner OFF ON switch OFF remote switches if applicable 5 When satisfied that the...

Страница 13: ...ctlytothe appliance on a pullout panel located within the control compartment TH TP TH TP Thermopile If any of the original wire as supplied must be replaced it must be replaced with Type AWM 105o C 1...

Страница 14: ...d system may be operated with electronic and mil livoltsystemswitheithernaturalgasorpropanegas The RCL T comes complete with detailed operating instructions Remote Control Kit Deluxe Cat No Model No D...

Страница 15: ...Doors Charcoal LMDV 4035 H0967 SPD40TI 40 Sq Pane Doors Textured Iron H0968 SPD40SP 40 Sq Pane Doors Satin Pewter H0969 SPD40AB 40 Sq Pane Doors Antique Brass Arch Design Arch Pane Design Square Desi...

Страница 16: ...nce These kits can be retrofitted to previously installed appliances ref Form 750 166M Polished Brass Brushed Stainless Hood Kits Attractive hoods are available in two styles These hoods are designed...

Страница 17: ...your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair ma...

Страница 18: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Страница 19: ...o many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service...

Страница 20: ...witch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote control A Wall switch or wires defective Check wall switch and wi...

Страница 21: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Страница 22: ...93L32 1 Lennox Nameplate Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT 43K07 1 88J53 1 13 Piezo Igniter 111061 1 111061 1 14...

Страница 23: ...23 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE REPLACEMENT PARTS 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMDV 4035 LMDVT 3328 LMDVR 3530...

Страница 24: ...P N 875 028M REV C 06 2005 LENNOX reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult you...