Lennox Crestline LSBV-3628EN Скачать руководство пользователя страница 19

19

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS   •   CRESTLINE™ SERIES B-VENT GAS FIREPLACES   •   36"/42" LSBV MODELS   •   INSTALLATION INSTRUCTIONS

Burner Orifice Sizes (all models)

Elevation

Feet (meters)

Natural

Gas

drill size (inches)

Propane

Gas

drill size (inches)

0-4500

(0-1372)

#26 (0.147") 

*

H5805  •

#45 (0.082")

*

39L66  •

Table 5

 

          

* Standard size installed at factory

                                        •  Part /Cat. Number

Figure 33

Figure 34

Step 9.

 Reassemble all removed components 

by  reversing  the  procedures  outlined  in  the 

preceding steps.  Use pipe joint compound or 

Teflon tape on all pipe fittings before installing 

(ensure propane resistant compounds are used 

in propane applications, do not use pipe joint 

compounds on flare fittings).

Step 10.

 Attach the conversion label provided 

in the conversion kit to the rating plate on the 

appliance.

Step 11.

 Turn on gas supply and test for gas 

leaks 

(see 

Step 6 

on

 

Page 8

).

Step 5.  Millivolt Systems

 – Attach manometer 

to the manifold side pressure test fitting and 

verify manifold pressure reads 3.5" water col-

umn (0.87 kPa) for natural gas, and 10.0" water 

column (2.49 kPa) for propane gas.

Step 6.

  See

 

Figure 31

 

 and remove the pilot 

hood assembly to access the hexed pilot orifice.  

Remove and replace the orifice with the one 

provided with the kit.

When reinstalling the igniter assembly, use 

extreme care to prevent damage and break-

age.  Do not apply any leverage to the igniter 

assembly while restoring the retainer clip to 

its original position

.

All Models

Step 8.

  Unscrew the orifice from the manifold 

and replace it with the one provided with the 

kit

.

 

  

See the following table for orifice sizes 

for  natural  and  propane  models. 

 Figure 34

 

 

illustrates the orifice.

Refer to 

Figure 32

  

and replace the pilot orifice 

as follows:  Remove the pilot hood assemble 

to access the hexed pilot orifice.

Remove the pilot orifice and replace it with the 

one provided with the conversion kit.  Reinstall 

the  pilot  assembly  by  reversing  the  steps 

detailed here.  

Pilot

Orifice

Pilot

Orifice

Electronic Appliances

Step 7.

 

SIT Electronic Valves

  -  See 

Figure 

33

  and  the  instructions  provided  with  the 

kit.    Remove  the  slotted  cap  screw,  o-ring, 

pressure-regulating adjusting screw and spring, 

then discard.  

Modify  the  pressure  regulator  from  the  kit.  

Using a standard tin snip cutting tool, proceed 

to trim shoulder off of the regulator.  

Install new components and modified pressure 

regulator from the kit.  

Attach manometer to the manifold side pressure 

test fitting and adjust screw until pressure reads 

3.5" water column (0.87 kPa) for natural gas, and 

10.0" water column (2.49 kPa) for propane gas.

Modified Kit

Pressure Regulator

- After Trim

Remove

These

Components

SIT VALVE

Kit Pressure

Regulator - Before

Trim

Figure 31

Figure 32

Gas Conversion Kits (continued)

Содержание Crestline LSBV-3628EN

Страница 1: ...our gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Ne pas entreposer ni utilizer d essence ni d autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil QUE FAIRE...

Страница 2: ...led withapprovedtype B 10 doublewallventpipe systems routed to the outside atmosphere GENERAL INFORMATION Please read and understand these instructions before beginning your installation Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition Lesenfantsetlesadultesdevraientêtreinfor mésdesdangersqueposentlestempératu...

Страница 3: ...gastobe lit without the use of matches or batteries This system provides continued service in the event of a power outage Input of for these models are shown in Table 1 Electronic Models Electronic models have a fixed rate gas valve Input of electronic models is shown in Table 1 Note Installation and repair should be done by a qualified service person The appliance should be inspected before use a...

Страница 4: ...er orificesizes marked with an in Table 4 For elevations above 4500 feet contact your gas supplier or qualified service technician Deration At higher elevations the amount of BTU fuel value delivered must be reduced by either Using gas that has been derated by the gas company By changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the USA N...

Страница 5: ...installed on combustible materials such as carpeting vinyltileorothercombustiblematerial other than wood flooring the appliance shall be installedona metalorwoodpanelextendingthe full width and depth of the appliance Typical Locations Figure 3 Figure 5 Figure 4 Vertical Vent Termination Clearances Termination Heights For Vents Above Flat Or Sloped Roofs Ref NFPA 54 ANSI Z223 1 Roof Pitch Feet Mete...

Страница 6: ...compartment Vertical installation clearances to combustible mantels vary according to the depth of the mantel See Figure 6 Mantels constructed of non combustible materials may be installed at any height above the appliance opening however do not allow anything to hang below the fireplace hood Minimum clearance requirements include any projections such as shelves window sills mantels etc above the ...

Страница 7: ... other thickness materials calculations will need to be made Corner Installation K D C A E G F Back Wall of Chase Enclosure Including Finishing Materials if any Rough Framing Face Unfinished Shown FOAK 4 Combustion Air Kit A H H C G Inside Chase Back Wall of Chase Enclosure Including Finising Materials if any Rough Framing Face Unfinished Shown FOAK Combustion Air Kit FOAK Combustion Air Kit A Out...

Страница 8: ...r personal injury AVERTISSEMENT Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvéesaveccetappareilsont utilisées Pre installation STEPS The fireplace may be installed directly on a combustible floor or raised on a platform of an appropriate height Do not place fireplace on carpeting vinyl...

Страница 9: ...the supply tank pressure to 13 w c maximum Any copper tubing used to supply propane L P G from the tank must be internally tinned Important Hold gas valve securely to preventmovementwhenconnectingto inlet gas line Figure 11 Step 4 Install the Vent System and Exterior Termination Slip a 10 254 mm B Vent system over the appliance collar Figure 11 and secure with foursheetmetalscrews 8orlarger Minimu...

Страница 10: ...n do not connect the wall switch to a 120V power supply Note The ends of the 18 coiled wire must be connected to the wall switch not supplied for the appliance to operate B ElectronicWiring Theelectronicappliance must be connected to the main power supply Toinstall routea3 wire120V60Hzpowersup ply to the appliance junction box and ground Locate and install a low voltage 24V wall switch not supplie...

Страница 11: ...ittings can result in corrosion over time Never use an open flame to check for leaks WARNING Never use an open flame to check for leaks TEST ALL CONNECTIONS FOR GAS LEAKS FACTORY AND FIELD Note The gas supply line must be installed in accor dance with building codes by a qualified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must ...

Страница 12: ... operation CAUTION NEVER LOCATE INLET of an outside air hood WHERE IT CAN BE BLOCKED BY SHRUBS SNOW DRIFTS ETC NEVER LOCATE INLET IN GARAGE OR ANY AREA WHERE THERE IS ANOTHER FUEL BURNING APPLIANCE OR PRODUCTS EMIT TING COMBUSTIBLE GASES SUCH AS PAINT GASOLINE ETC IN COLD CLIMATES IT IS RECOMMENDEDTHECOMBUSTIONAIRDUCT BE INSULATED Outside combustion air ducting may be run upwards or vertically thr...

Страница 13: ... and tear into quarter size pieces as shown in Figure 21 Spread across the front part of the burner Do Not use more than is necessary to cover the burner When properly positioned the Glowing Embers will unevenly cover approximately 85 of the burner with no appreciable gaps Figure 21 Bottom Log Log Grate Glowing Embers Figure 22 Figure 23 Step 3 Place the left log as shown in Figure 22 on the landi...

Страница 14: ...ttheburner turn ON theoptionalremote wall switch Ensure the igniter lights the pilot The pilot flame should engulf the flame rod as shown in Figure 28 Figure 27 Millivolt Appliance Checkout The pilot flame should be steady not lifting or floating Flame should be blue in color with traces of orange at the outer edge The top 3 8 9 mm at the pilot generator thermopile should be engulfed in the pilot ...

Страница 15: ...a flame which is blueatthebaseandbecomesyellowish orange in the body of the flame When the appliance is first lit the entire flame may be blue and will graduallyturnyellowish orangeduringthefirst 15 minutes of operation After 15 minutes of operation if the flame is blue or if the flame is orange with evidence of sooting black tip the air shutter opening may need to be adjusted Iftheairshutteropeni...

Страница 16: ...races de graisse ou d huile Collez l étiquette sur le boîtier de la télécommande Figure B Choisissez la langue qui est principale ment parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 3 Si vous ne trouvez pas les étiquettes veuillez appeler Lennox Hearth Products ou votre distribu teur Lennox Hearth Products local pour recevoir gratuitement des étiquettes supp...

Страница 17: ... wallswitchinaconvenientlocationnearthefireplace White WallSwitchKit Cat No Model No Description 85L87 FWSK OFF ONWallSwitchKit G Fire Remote Simple On Off Cat No Model No Description H8840 KIT RC G FIRE Remote Control Cost Effective Solution Simple On Off operation Workswithmillivoltandlowvoltageelectronic ignition controls Kit includes Remote and Receiver Wall Control 4 button timer with 30 60 1...

Страница 18: ...G l a r u t a N o t e n a p o r P s l e d o M e p y T t i n U o N g o l a t a C 8 2 6 3 V B S L t l o v i l l i m 2 1 8 5 H 8 2 2 4 V B S L t l o v i l l i m 2 1 8 5 H s m e t s y S T I S c i n o r t c e l E s t i K n o i s r e v n o C s a G e n a p o r P o T l a r u t a N s l e d o M e p y T t i n U o N g o l a t a C 8 2 6 3 V B S L c i n o r t c e l e 5 1 8 5 H 8 2 2 4 V B S L c i n o r t c e l ...

Страница 19: ...stalling the igniter assembly use extreme care to prevent damage and break age Do not apply any leverage to the igniter assembly while restoring the retainer clip to its original position All Models Step 8 Unscrew the orifice from the manifold and replace it with the one provided with the kit See the following table for orifice sizes for natural and propane models Figure 34 illustrates the orifice...

Страница 20: ...s Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNOX and other related LENNOX marks are registered or common law trademarks of Lennox Industries Inc and are used with permission LENNOX HEARTH PRODUCTS CRESTLINE SERIES B VENT GAS FIREPLACES 36 42 LSBV MODELS INSTALLATION INSTRUCTIONS Printed in U S A 2007 Lennox Hearth Product...

Отзывы: