Lennox Crestline LSBV-3628EN Скачать руководство пользователя страница 18

18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS   •   CRESTLINE™ SERIES B-VENT GAS FIREPLACES   •   36"/42" LSBV MODELS   •   INSTALLATION INSTRUCTIONS

Figure 30

Pressure

Regulator

Remove

These

Components

Step 1.

 

TURN OFF THE GAS SUPPLY TO THE 

APPLIANCE and disconnect power supply  at 

the circuit breaker. Ensure appliance is cold. 

Remove the front glass door (if used) from the 

appliance. Access the control compartment.

Step 2.

 Carefully remove the logs.  Exercise 

care as not to break the logs.

Step 3.

 Locate the screw securing the burner.  

Remove  the  burner  and  retain  the  securing 

screw.

Millivolt Appliances

Step 4.

 

SIT Systems

 - Refer to

 Figure 30

  and 

the instructions provided with the kit.  Using a 

Torx T20, remove and discard the three pressure 

regulator mounting screws.  

Remove the pressure regulator, spring, poppet, 

diaphragm and bushing.  

Discard all removed 

components

.    Ensure  the  rubber  gasket  in-

stalled on the back of the replacement pressure 

regulator is properly positioned and install the 

new pressure regulator using the new screws 

supplied  with  the  kit.    Tighten  screws  to  25 

in-lbs of torque.

In Canada

THE CONVERSION SHALL BE CAR-

RIED OUT IN ACCORDANCE WITH THE 

REQUIREMENTS OF THE PROVINCIAL 

AUTHORITIES HAVING JURISDICTION 

AND IN ACCORDANCE WITH THE RE-

QUIREMENTS OF THE CAN/CGA-B149.1 

INSTALLATION CODE.

LA CONVERSION DEVRA êTRE EF-

FECTUéE CONFORMéMENT AUx RE-

COMMANDATIONS DES AUTORITéS 

PROVINCIALES AYANT JURIDICTION 

ET CONFORMéMENT AUx ExIGENCES 

DU CODE D'INSTALLATION CAN/CGA-

B149.1.

Gas conversion kits are available to adapt your 

appliance from the use of one type of gas to 

the use of another. These kits contain all the 

necessary components needed to complete the 

task including labeling that must be affixed to 

ensure safe operation.

-

s

m

e

t

s

y

S

T

I

S

tl

o

v

il

li

M

s

ti

K

n

o

i

s

r

e

v

n

o

C

s

a

G

e

n

a

p

o

r

P

o

T

l

a

r

u

t

a

N

s

l

e

d

o

M

e

p

y

T

ti

n

U

.

o

N

g

o

l

a

t

a

C

8

2

6

3

-

V

B

S

L

tl

o

v

il

li

m

4

1

8

5

H

8

2

2

4

-

V

B

S

L

tl

o

v

il

li

m

4

1

8

5

H

-

s

m

e

t

s

y

S

T

I

S

tl

o

v

il

li

M

s

ti

K

n

o

i

s

r

e

v

n

o

C

s

a

G

l

a

r

u

t

a

N

o

t

e

n

a

p

o

r

P

s

l

e

d

o

M

e

p

y

T

ti

n

U

.

o

N

g

o

l

a

t

a

C

8

2

6

3

-

V

B

S

L

tl

o

v

il

li

m

2

1

8

5

H

8

2

2

4

-

V

B

S

L

tl

o

v

il

li

m

2

1

8

5

H

-

s

m

e

t

s

y

S

T

I

S

c

i

n

o

rt

c

e

l

E

s

ti

K

n

o

i

s

r

e

v

n

o

C

s

a

G

e

n

a

p

o

r

P

o

T

l

a

r

u

t

a

N

s

l

e

d

o

M

e

p

y

T

ti

n

U

.

o

N

g

o

l

a

t

a

C

8

2

6

3

-

V

B

S

L

c

i

n

o

rt

c

e

l

e

5

1

8

5

H

8

2

2

4

-

V

B

S

L

c

i

n

o

rt

c

e

l

e

5

1

8

5

H

-

s

m

e

t

s

y

S

T

I

S

c

i

n

o

rt

c

e

l

E

s

ti

K

n

o

i

s

r

e

v

n

o

C

s

a

G

l

a

r

u

t

a

N

o

t

e

n

a

p

o

r

P

s

l

e

d

o

M

e

p

y

T

ti

n

U

.

o

N

g

o

l

a

t

a

C

8

2

6

3

-

V

B

S

L

c

i

n

o

rt

c

e

l

e

3

1

8

5

H

8

2

2

4

-

V

B

S

L

c

i

n

o

rt

c

e

l

e

3

1

8

5

H

GAS CONVERSION KITS

            

WARNING

This conversion kit shall be installed by a qualified service agency in 

accordance with the manufacturer’s instructions and all applicable codes 

and requirements of the authority having jurisdiction. If the information in 

these instruction is not followed exactly, a fire, explosion or production of 

carbon monoxide may result causing property damage, personal injury 

or loss of life. The qualified service agency is responsible for the proper 

installation of this kit. The installation is not proper and complete until the 

operation of the converted appliance is checked as specified in the manu-

facturer’s instructions supplied with the kit. The qualified service agency 

performing this installation assumes responsibility for this conversion.

            

AVERTISSEMENT

Cette trousse de conversion doit être installée par un technicien agréé, 

selon les instructions du fabricant et selon toutes les exigences et tous les 

codes pertinents de l’autorité compétente. Assurez-vous de bien suivre 

les instructions dans cette notice pour réduire au minimum le risque 

d’incendie, d’explosion ou la production de monoxyde de carbone pouvant 

causer des dommages matériels, des blessures ou la mort. Le tecnicien 

agréé est responsable de l’installation de cette trousse. L’installation n’est 

pas adéquate ni complète tant que le bon fonctionnement de l’appareil 

converti n’a pas été vérifié selon les instructions du fabricant fournies avec 

la trousse.  Le fournisseur de service qualifié ayant réalisé l'installation 

assume les responsabilités liées à la conversion.

Kit part numbers are listed here and the steps 

that follow detail the conversion procedure. 

Содержание Crestline LSBV-3628EN

Страница 1: ...our gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Ne pas entreposer ni utilizer d essence ni d autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil QUE FAIRE...

Страница 2: ...led withapprovedtype B 10 doublewallventpipe systems routed to the outside atmosphere GENERAL INFORMATION Please read and understand these instructions before beginning your installation Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition Lesenfantsetlesadultesdevraientêtreinfor mésdesdangersqueposentlestempératu...

Страница 3: ...gastobe lit without the use of matches or batteries This system provides continued service in the event of a power outage Input of for these models are shown in Table 1 Electronic Models Electronic models have a fixed rate gas valve Input of electronic models is shown in Table 1 Note Installation and repair should be done by a qualified service person The appliance should be inspected before use a...

Страница 4: ...er orificesizes marked with an in Table 4 For elevations above 4500 feet contact your gas supplier or qualified service technician Deration At higher elevations the amount of BTU fuel value delivered must be reduced by either Using gas that has been derated by the gas company By changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the USA N...

Страница 5: ...installed on combustible materials such as carpeting vinyltileorothercombustiblematerial other than wood flooring the appliance shall be installedona metalorwoodpanelextendingthe full width and depth of the appliance Typical Locations Figure 3 Figure 5 Figure 4 Vertical Vent Termination Clearances Termination Heights For Vents Above Flat Or Sloped Roofs Ref NFPA 54 ANSI Z223 1 Roof Pitch Feet Mete...

Страница 6: ...compartment Vertical installation clearances to combustible mantels vary according to the depth of the mantel See Figure 6 Mantels constructed of non combustible materials may be installed at any height above the appliance opening however do not allow anything to hang below the fireplace hood Minimum clearance requirements include any projections such as shelves window sills mantels etc above the ...

Страница 7: ... other thickness materials calculations will need to be made Corner Installation K D C A E G F Back Wall of Chase Enclosure Including Finishing Materials if any Rough Framing Face Unfinished Shown FOAK 4 Combustion Air Kit A H H C G Inside Chase Back Wall of Chase Enclosure Including Finising Materials if any Rough Framing Face Unfinished Shown FOAK Combustion Air Kit FOAK Combustion Air Kit A Out...

Страница 8: ...r personal injury AVERTISSEMENT Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvéesaveccetappareilsont utilisées Pre installation STEPS The fireplace may be installed directly on a combustible floor or raised on a platform of an appropriate height Do not place fireplace on carpeting vinyl...

Страница 9: ...the supply tank pressure to 13 w c maximum Any copper tubing used to supply propane L P G from the tank must be internally tinned Important Hold gas valve securely to preventmovementwhenconnectingto inlet gas line Figure 11 Step 4 Install the Vent System and Exterior Termination Slip a 10 254 mm B Vent system over the appliance collar Figure 11 and secure with foursheetmetalscrews 8orlarger Minimu...

Страница 10: ...n do not connect the wall switch to a 120V power supply Note The ends of the 18 coiled wire must be connected to the wall switch not supplied for the appliance to operate B ElectronicWiring Theelectronicappliance must be connected to the main power supply Toinstall routea3 wire120V60Hzpowersup ply to the appliance junction box and ground Locate and install a low voltage 24V wall switch not supplie...

Страница 11: ...ittings can result in corrosion over time Never use an open flame to check for leaks WARNING Never use an open flame to check for leaks TEST ALL CONNECTIONS FOR GAS LEAKS FACTORY AND FIELD Note The gas supply line must be installed in accor dance with building codes by a qualified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must ...

Страница 12: ... operation CAUTION NEVER LOCATE INLET of an outside air hood WHERE IT CAN BE BLOCKED BY SHRUBS SNOW DRIFTS ETC NEVER LOCATE INLET IN GARAGE OR ANY AREA WHERE THERE IS ANOTHER FUEL BURNING APPLIANCE OR PRODUCTS EMIT TING COMBUSTIBLE GASES SUCH AS PAINT GASOLINE ETC IN COLD CLIMATES IT IS RECOMMENDEDTHECOMBUSTIONAIRDUCT BE INSULATED Outside combustion air ducting may be run upwards or vertically thr...

Страница 13: ... and tear into quarter size pieces as shown in Figure 21 Spread across the front part of the burner Do Not use more than is necessary to cover the burner When properly positioned the Glowing Embers will unevenly cover approximately 85 of the burner with no appreciable gaps Figure 21 Bottom Log Log Grate Glowing Embers Figure 22 Figure 23 Step 3 Place the left log as shown in Figure 22 on the landi...

Страница 14: ...ttheburner turn ON theoptionalremote wall switch Ensure the igniter lights the pilot The pilot flame should engulf the flame rod as shown in Figure 28 Figure 27 Millivolt Appliance Checkout The pilot flame should be steady not lifting or floating Flame should be blue in color with traces of orange at the outer edge The top 3 8 9 mm at the pilot generator thermopile should be engulfed in the pilot ...

Страница 15: ...a flame which is blueatthebaseandbecomesyellowish orange in the body of the flame When the appliance is first lit the entire flame may be blue and will graduallyturnyellowish orangeduringthefirst 15 minutes of operation After 15 minutes of operation if the flame is blue or if the flame is orange with evidence of sooting black tip the air shutter opening may need to be adjusted Iftheairshutteropeni...

Страница 16: ...races de graisse ou d huile Collez l étiquette sur le boîtier de la télécommande Figure B Choisissez la langue qui est principale ment parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 3 Si vous ne trouvez pas les étiquettes veuillez appeler Lennox Hearth Products ou votre distribu teur Lennox Hearth Products local pour recevoir gratuitement des étiquettes supp...

Страница 17: ... wallswitchinaconvenientlocationnearthefireplace White WallSwitchKit Cat No Model No Description 85L87 FWSK OFF ONWallSwitchKit G Fire Remote Simple On Off Cat No Model No Description H8840 KIT RC G FIRE Remote Control Cost Effective Solution Simple On Off operation Workswithmillivoltandlowvoltageelectronic ignition controls Kit includes Remote and Receiver Wall Control 4 button timer with 30 60 1...

Страница 18: ...G l a r u t a N o t e n a p o r P s l e d o M e p y T t i n U o N g o l a t a C 8 2 6 3 V B S L t l o v i l l i m 2 1 8 5 H 8 2 2 4 V B S L t l o v i l l i m 2 1 8 5 H s m e t s y S T I S c i n o r t c e l E s t i K n o i s r e v n o C s a G e n a p o r P o T l a r u t a N s l e d o M e p y T t i n U o N g o l a t a C 8 2 6 3 V B S L c i n o r t c e l e 5 1 8 5 H 8 2 2 4 V B S L c i n o r t c e l ...

Страница 19: ...stalling the igniter assembly use extreme care to prevent damage and break age Do not apply any leverage to the igniter assembly while restoring the retainer clip to its original position All Models Step 8 Unscrew the orifice from the manifold and replace it with the one provided with the kit See the following table for orifice sizes for natural and propane models Figure 34 illustrates the orifice...

Страница 20: ...s Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNOX and other related LENNOX marks are registered or common law trademarks of Lennox Industries Inc and are used with permission LENNOX HEARTH PRODUCTS CRESTLINE SERIES B VENT GAS FIREPLACES 36 42 LSBV MODELS INSTALLATION INSTRUCTIONS Printed in U S A 2007 Lennox Hearth Product...

Отзывы: