NAMES AND FUNCTIONS OF THE PARTS

1 TRANSMISSION INDICATOR LIGHT

This indicator light shows when a command has been
sent to the appliance.

2 TIME DISPLAY

This indicates both the current and the set time (AM,
PM, from 1:00 a 12:59).

3 OPERATING MODE DISPLAY

  This  shows  the  mode  of  operation  (cooling,

dehumidifying, etc.).

4 TIME SETTING DISPLAY

This shows the time which the appliance should start
operating.

5 TEMPERATURE SETTING DISPLAY

 This shows the thermostat setting.

6 FAN SPEED DISPLAY

This shows the current fan speed.

7 NIGHT AND AIR CLEANING FUNCTION DISPLAY

This shows that the night and negative ion generation
functions have been set.

8 TIMER MODE DISPLAY

This shows the current time, timer off, timer on.

REMOTE CONTROL DISPLAY

The illustration shows the control display with all the indicator lights

lit; only the currently request indicator lights, however, displayed

upon actual use.

- The signals will not be transmitted correctly if a wall, curtain or other objects are situated between the FAN COIL and the remote

control.

- The fancoil could operate incorrectly if strong light falls directly on the signal receiver. Use a curtain to protect from direct sunlight

and place any lamp with a strong light far from the signal receiver.

- If there is another electronic appliance operating by remote control, move it or contact the authorised after-sales service.

- Do  not  put  the  remote  control  in  a  place  where  it  could  be  exposed  to  direct  sunlight  or  near  heating  appliances.

- Protect  the  remote  control  against  heavy  impact  and  do  not  allow  water  or  other  liquids  to  be  sprayed  onto  it.

- When the remote control is used in rooms where there are quick start lamps, the FAN COIL may not receive the signals correctly.

ATTENTION!

PREPARATION

1 Make sure that the unit is connected to the electricy

supply.

2 Open the front cover
3 Put the power switch to on
4 Close the front cover

POWER SUPPLY

1 Use both hands to pull the button edge of the front cover

forwards by 30°

2 Use both hands to push the front cover upwards, raising

it.

OPENING  AND  CLOSING  THE  FRONT  COVER

2

1

ON - OFF

Don't operate the unit with the front cover open, since

malfunctioning could occur.

Fit the hooks located at the top of the base unit into the holes in the top of the front cover grille and then press the
bottom of the cover on both sides to lock it into place.

INSTALLATION 

- OPERATING & 

MAINTENANCE

 MANU

A

L

 

Page 6

Содержание Comfair HD

Страница 1: ...INSTALLATION OPERATING MAINTENANCE MANUAL Comfair HD ENGLISH MARCH 04...

Страница 2: ......

Страница 3: ...Don t place objects on the fancoil Don t allow water to come into direct contact with the fancoil Don t direct the airflow into a fireplace or heating appliance Don t touch the fins of the heat exchan...

Страница 4: ...Provide a hole on the wall with the following dimensions From the hole the system water pipes are coming out A 500 B 80 H 60 SYSTEM WATER PIPES L H A Provide fancoil supporting template fixing to the...

Страница 5: ...es B 16 5 mm condensate drain pipe 400 500 550 B A 490 500 157 A B Hidraulic connections and condansate drain pipe dimension 4 Elevate the fancoil from the lower part and providehidraulic connections...

Страница 6: ...T YELLOW This comes on when the timer is operating It blinks when the protection system is operating SIGNALLINGS AND AUXILIARY KEYS OF CONTROL 1 EMERGENCY BUTTON The emergency button may be used to ac...

Страница 7: ...s button to select the fan speed automatic low medium high 10 AUTO Press this button to set the airflow direction in the automatic mode 11 OFF timer Set the time for when fancoil operation should stop...

Страница 8: ...rectly on the signal receiver Use a curtain to protect from direct sunlight and place any lamp with a strong light far from the signal receiver If there is another electronic appliance operating by re...

Страница 9: ...ING THE CURRENT TIME 1 Press the CLOCK button 2 Use the buttons to set the clock to the current time Button press this button to put the time forward Button press this button to put the time back Each...

Страница 10: ...room temperature The modes of operation have been set as described below Cooling above 25 C Dehumidifying 20 C 25 C Heat pump below 20 C Cooling Dehumidifying only with solenoid valve installed Heat...

Страница 11: ...AUTO cooling operation is as follows 2 When the fan speed isn t set on AUTO the cooling mode of operation is as follows The difference in temperature DT1 DTa 3 0 C 0 5 C DT2 DTb 2 0 C 0 5 C Set temp 4...

Страница 12: ...o set the flaps by hand since this could cause malfunction In the event of malfunction switch off the FAN COIL momentarily and then switch on again to allow the flaps to return to the correct position...

Страница 13: ...5 until 75 when in the cooling mode from 10 until 50 in the heating mode d If this button is kept pressed the flaps move continuously the direction of airflow may be set by releasing the button when t...

Страница 14: ...s correct 1 PRESS THE OFF KEY The message OFF TIMER flashes on display and the start up time below 2 SET THE SHUTDOWN TIME AS REQUIRED To change setting use the following button to decrease the value...

Страница 15: ...other soft clean dry cloth Depending on the conditions of use the internal parts of the unit become dirty after 2 or 3 seasons of use and efficiency could be jeopardised For this reason the indicated...

Страница 16: ...bacco and other things present in the room During cooling and dehumidifying operations slight mist could be emitted by the unit This is caused by the sudden cooling which produces condensation and mis...

Страница 17: ......

Страница 18: ...A Sp z o o tel 48 22 832 26 61 fax 48 22 832 26 62 e mail lennoxpolska inetia pl LENNOX CLIMATIZA AO LDA tel 351 22 998 33 70 fax 351 22 998 33 79 e mail marketing lennoxportugal com JANKA RADOTIN AS...

Отзывы: