Application Guide • COMFAIR HD-AGU-1107-E
INSTALLATION - HD
INSTALLATION WITH SIMPLE MOUNTING PLATE
The method of installing the wall-mounted water-fi lled fan coil of the HD range is shown below. Take into account the following:
- Looking at the unit from the front, the supply pipes go from right to left.
- The system pipes must come from the left.
Make suffi cient large hoel in the wall for the system water pipes
to pass through.
SYSTEM
WATER PIPES
SYSTEM
WATER PIPES
HOSE
Take two hoses with 1/2" fi tting and connect to the systems pipes.
These pipes must be lagged.
MOUNTING PLATE
MOUNTING PLATE
Fix the fan coil mounting plate to the wall.
HD
Anchor the fan coil to the mouting plate
Tilt the fan coil and insert the relative polystyrene foam spacer and
then carry out the water connections
Put the fan coil back to its position of operation
SIZE OF WATER AND CONDENSATE DRAIN FITTINGS
HD1 AND HD2
HD3
A:
Hoses for water connection Ø 1/2"
B:
Condensate drain pipe Ø 16,5 mm