Specifications 

General Data

Model No.

CH35

-48B-2F

CH35

-48C-2F

CH35

-51C-2F

CH35

-60D-2F

Nominal size - tons

3.5 / 4

3.5 / 4

4

5

Line
Connections

Suction/Vapor o.d. - in. sweat

7/8

7/8

7/8

7/8

Liquid o.d. - in. sweat

3/8

3/8

3/8

3/8

Condensate drain (fpt) - in.

3/4

3/4

3/4

3/4

Evaporator
Coil

Net face area - sq. ft.

5.78

5.83

7.22

7.94

Tube diameter - in.

3/8

3/8

3/8

3/8

Number of rows

3

2

3

3

Fins per inch

12

12

13

12

Horizontal
Matching
Furnace

Cabinet Designation

B

C

C

D

Coil and Furnace Height

17-1/2

21

21

24-1/2

Shipping Data

lbs. - 1 package

60

59

69

78

Releasing Air Charge

CAUTION

The coil is shipped from the factory pressurized with dry
air. Pierce a hole in the rubber plug that seals the vapor
line to relieve the pressure before removing the plugs.

NOTE

 - If there is no pressure released when the vapor

line rubber plug is pierced, check the coil for leaks before
continuing with the installation.

The coil is shipped with a 10 + 3 psig dry air holding charge.
Puncture the suction line rubber plug to release the
charge. Remove the rubber plug. Ensure that the coil is
void of pressure.

Installation

WARNING

Risk of explosion or fire.

Can cause injury or death.

Recover all refrigerant to relieve pressure before open­
ing the system.

Install the furnace or air handler according to the
installation instructions provided with the unit.

NOTE

 - In areas of high humidity, use foam tape to insulate

the suction line section in the cabinet as shown in figure 1.

FOAM
TAPE

Figure 1. Insulate Suction Line Inside Cabinet

1.

Left-Hand and Right-Hand Discharge

 — 

The coil

must have a 1/2" slope from the rear of the cabinet
to the drain. 

Position the coil adjacent to the furnace

cabinet and align the six screw clearance holes in the
coil casing with the furnace engagement holes. Use
six field-provided #8 X 1" screws to secure the coil
casing to the furnace (see figures 3 and 4).

2.

Right-Hand Air Discharge with Field-Provided
Spacer

 — 

The coil must have a 1/2" slope from the

rear of the cabinet to the drain. 

Position the coil in

the left-to-right configuration on the service access
side of the furnace. Insert a field-provided spacer
between the furnace and the coil. Use field-provided
screws to secure the coil casing, spacer and the
furnace together. The spacer should be long enough
to allow room for proper installation (approximately 6
inches minimum). See figure 5.

Содержание CH35 Series

Страница 1: ...ne Connections 5 Leak Testing Evacuating and Charging 6 Sealing Ducts 6 Condensate Drain Connection 6 Blower Speed Connection 7 Maintenance 8 General CH35 all aluminum coil horizontal evaporator coils...

Страница 2: ...3 8 3 8 3 8 Condensate drain fpt in 3 4 3 4 3 4 3 4 3 4 Evaporator Coil Net face area sq ft 1 75 3 5 3 5 4 33 4 67 Tube diameter in 3 8 3 8 3 8 3 8 3 8 Number of rows 2 3 2 3 3 Fins per inch 18 14 19...

Страница 3: ...d of pressure Installation WARNING Risk of explosion or fire Can cause injury or death Recover all refrigerant to relieve pressure before open ing the system Install the furnace or air handler accordi...

Страница 4: ...LY AIR UNIT REAR TEST HOLE AIR FLOW FIELD FABRICATED INSULATED BLOCK OFF PLATE Figure 2 D Width Coil with C Width Furnace Top View SUPPLY AIR UNIT FRONT PLUMBING CONNECTIONS SUPPLY AIR UNIT REAR AIR F...

Страница 5: ...eat damage during brazing See figure 7 WATER SATURATED RAGS PLACE A WET RAG AGAINST COIL CABINET AND AROUND THE SUCTION LINE CONNECTION BRAZE CONNECTION ALLOW PIPE TO COOL BEFORE REMOVING WET RAG 1 2...

Страница 6: ...e coil cabinet flanges WARNING There must be an airtight seal between the bottom of the furnace and the return air plenum Use fiberglass sealing strips caulking or equivalent sealing method between th...

Страница 7: ...EADING SECONDARY DRAIN PAN 2 51MM TRAP DEPTH P TRAP 49P66 REQUIRES A LARGER INSTALLATION SPACE THAN THE J TRAP 91P90 Figure 10 Typical Main and Overflow Drain Installations Blower Speed Connection Pro...

Страница 8: ...his or any other maintenance turn off all power to the indoor unit at the main unit disconnect switch It is also recommended that you wear personal protective gear safety glasses and or a face shield...

Отзывы: