Page 1
THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause personal injury, loss of life, or
damage to property.
Installation and service must be performed by a licensed
professional installer (or equivalent) or a service agency.
WARNING
Risk of explosion or fire.
Can cause injury or death.
Recover all refrigerant to relieve pressure before
opening the system.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing
.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
INSTALLATION
INSTRUCTIONS
CH35
Series Units
INDOOR COILS WITH ALL-ALUMINUM COIL
507656-01
7/2018
NOTE -
Not available in all areas. Contact your nearest
Lennox Sales Office for details.
Table of Contents
General
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shipping and Packing List
. . . . . . . . . . . . . . . . . . . . . .
Specifications
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Releasing Air Charge
3
. . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refrigerant Line Connections
. . . . . . . . . . . . . . . . . . .
Leak Testing, Evacuating and Charging
. . . . . . . . . .
Sealing Ducts
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Condensate Drain Connection
. . . . . . . . . . . . . . . . . .
Blower Speed Connection
. . . . . . . . . . . . . . . . . . . . . .
Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General
CH35
all-aluminum
coil
horizontal evaporator coils are
designed for use with air conditioners and heat pumps.
Each coil is equipped with a compression fitting that
provides convenient field installation of a properly sized,
separately ordered expansion valve.
The coil drain pan is high quality engineering polymer with
a maximum service temperature of 500°F. However,
adequate space must be provided between the drain pan
and furnace heat exchanger. At least 2" space is required
for heat exchanger and 4" for drum-type or oil-fired furnace
heat exchanger. Closer spacing may damage the drain
pan and cause leaking.
Refer to the CH35 Product Specification bulletin (EHB) for
proper use of these coils with specific furnaces, air
conditioners, heat pumps and line sets.
These instructions are intended as a general guide and do
not supersede local or national codes in any way. Consult
authorities who have jurisdiction before installation.
IMPORTANT:
Special procedures are required for
cleaning the aluminum coil in this unit. See page 8 in this
instruction for information.
Shipping and Packing List
Package 1 of 1 contains the following:
1 - CH35 evaporator coil
Check the components for shipping damage. If you find
any damage, immediately contact the last carrier.