Page - IOM / @DNOVA-µAC-0907-E
ALARMs AnD sIGnALs
table of alarms
n.
cod.
Description
Delay
Reset
Buzz.
Alarm c1
c2
R1
R2
sys/on Fan
out6
out1
out2
out3
out4
out5
Y2
1
E1
probe B1
1 min
P5
ON
ON
OFF
OFF
OFF
OFF
-
-
2
E2
probe B2
1 min
P5
ON
ON
-
-
-
-
-
-
3
E3
probe B3
1 min
P5
ON
ON
-
-
-
-
-
-
4
E4
probe B4
1 min
P5
ON
ON
-
-
-
-
-
-
5
Er: E
EEPROM boot
imm.
Auto
-
-
OFF
OFF
OFF
OFF
OFF
OFF
6
EE
EEPROM run
imm.
Auto
ON
ON
-
-
-
-
-
-
7
EL
insuff. Power
imm.
Auto
ON
ON
-
-
-
-
-
-
8
H1
high press C1
imm.
Man
ON
ON
OFF
-
-
-
-
-
9
H2
high press C2
imm.
man
ON
ON
-
OFF
-
-
-
-
10
L1
low press C1
P3
P5
ON
ON
OFF
-
-
-
-
-
11
L2
low press C2
P3
P5
ON
ON
-
OFF
-
-
-
-
12
F1
filter dirty
imm.
P5
ON
ON
-
-
-
-
-
-
13
FL
flow
P1/2
P5
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
14
FA
smoke-fire
imm.
P5
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
15
CF
water flow
imm.
P5
ON
ON
-
-
-
-
-
-
16
r1
heating elements
imm.
man
ON
ON
-
-
OFF
OFF
-
-
17
At
supply temp
2min
P5
ON
ON
OFF
OFF
-
-
-
-
18
AH
humidifier
30 s
P5
ON
ON
-
-
-
-
-
-
19
Lt
low temp.
PA
P5
ON
ON
-
-
-
-
-
-
20
Ht
high temp.
PA
P5
ON
ON
ON
ON
-
-
-
-
21
ht
high temp. prealarm PA
P5
ON
ON
-
-
-
-
-
-
22
LH
low humid.
PA
P5
ON
ON
-
-
-
-
-
-
23
HH
high humid.
PA
P5
ON
ON
-
-
-
-
-
-
24
tC
comp. thermal
imm.
P5
ON
ON
OFF
-
-
-
-
-
25
tF
fan thermal
imm.
P5
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
26* t1 / t2
fan 1-2 thermal
imm.
P5
ON
ON
-
-
-
-
OFF(1) -
28
AL
serious generic
PC
Pb
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
29
PA
power fail
2 s
auto
ON
ON
OFF
-
OFF
-
-
-
30
CL
clock
imm
man
ON
ON
-
-
-
-
-
-
31
n1 +
counter comp.1
imm.
c9
ON
ON
-
-
-
-
-
-
32
n2 +
counter comp.2
imm.
cA
ON
ON
-
-
-
-
-
-
33
nF +
counter filter
imm.
FC
ON
ON
-
-
-
-
-
-
34
nn +
counter fan
imm.
FA
ON
ON
-
-
-
-
-
-
=
serious alarms:
in the configuration with two alarm relays, these activate the alarm output; the other alarms, ON the
other hand, activate the dehumidification.
In the event of an alarm, the machine performs the following
actions:
• activates the buzzer and display
, (if enabled and machine
ON);
• activates the alarm relay (according to parameters HF,
HA);
• displays the alarm code and switches on the corresponding
red LED.
In this condition, pressing the alarm button silences the buzzer.
The termination of alarms with automatic reset, if no alarms
with manual reset are active, brings about:
• the switching off of the buzzer;
• the deactivation of the alarm relay, see parameter HF;
• the switching off of the red alarm LED;
• the re-activation of the actuators switched off by the alarm.
Pressing the and buttons together for 2 seconds cancels
the display of the alarm codes. In the event of alarms with
manual reset, pressing the and buttons together for 2
seconds brings about:
• the deactivation of the alarm relay, see parameter HF;
• the switching off of the red alarm LED;
• the re-activation of the actuators switched off by the alarm.
The maintenance signals for compressors 1 and/or 2, the
fan and the filter, due to the exceeding of the hour counter
thresholds, activate the symbol
on the display, the red
LED, the buzzer and the alarm relay. The alarm messages are
shown cyclically in the order indicated in the following table.
On termination, the display of the percentage of humidity (if
present) returns for 6 seconds.
ALARM AND SIGNALS