INSTALLATION

These instructions explain the recommended method of
installation of the SA electric cooling unit and associated
electrical wiring.

This unit is designed and approved for use as a self-
contained air-to-air air conditioning system.

The units are factory equipped with a transformer and
blower control for applications without auxiliary heat.
Electric heat accessory kits (PHK) can be ordered for field
installation of additional heat where required.

These instructions, and any instructions packaged with
mating components and/or accessories, should be care-
fully read prior to beginning installation. Note particularly
any 

CAUTIONS

 or 

WARNINGS

 in these instructions and

all labels on the units.

These instructions are intended as a general guide only, for
use by qualified personnel and do not supersede any national
or local codes in any way. Compliance with all local, state,
provincial, or national codes pertaining to this type of
equipment should be determined prior to installation.

IMPORTANT: This product has been designed and manufac-
tured to meet ENERGY STAR criteria for energy efficiency.
However, proper refrigerant charge and proper air flow are
critical to achieve rated capacity and efficiency. Installation
of this product should follow the manufacturer’s refrigerant
charging and air flow instructions. 

Failure to confirm

proper charge and airflow may reduce energy effi-
ciency and shorten equipment life.

Inspection of Shipment

Upon receipt of equipment, carefully inspect it for possible
shipping damage. If damage is found, it should be noted on
the carrier’s freight bill. Take special care to examine the
unit inside the carton if the carton is damaged. File a claim
with the transportation company.

If any damages are discovered and reported to the carrier
DO NOT INSTALL THE UNIT, 

as claim may be denied

.

Check the unit rating plate to confirm specifications
are as ordered.

Limitations

The unit should be installed in accordance with all national
and local safety codes.

Limitations of the unit and appropriate accessories must
also be observed.

The unit must not be installed with any ductwork in the
outdoor air stream. The outdoor fan is not designed to
operate against any additional static pressure.

Location

The unit is designed to be located outdoors with sufficient
clearance for free entrance to the air inlet and discharge air
openings. The location must also allow for adequate
service access.

The unit must be installed on a solid foundation that will not
settle or shift. Adequate structural support must be pro-
vided. Maintain minimum clearances as shown in Figure 1
and Table 1 and install the unit in level position. Isolate the
base from the building structure to avoid possible transmis-
sion of sound or vibration into the conditioned space.

Avoid placing the unit near quiet areas such as
sleeping quarters or study rooms.

 Normal operating

sound levels may be objectionable if the unit is placed
near certain rooms.

Do not permit overhanging structures or shrubs to
obstruct condenser air discharge inlet or outlet.

For improved start-up performance, the indoor coil
should be washed with suitable detergent to remove
any residue from manufacturing processes.

Exercise care when moving the unit. Do not remove any
packaging until the unit is near the place of installation. An
accessory lift kit can be purchased to aid in rigging (see
Figure 1). Spreaders whose length exceed the largest
dimension across the unit 

must be used across the top

of the unit. 

Recommended spreader length: 3 ton and smaller

package units – 44", 3.5 ton and larger units – 54".

Using Accessory Lift Kit

Figure 1

To avoid possible
damage to unit
panels from lifting
clevis, place
packing material
between clevis
and panels before
lifting unit.

Spreaders

(Field Supplied)

Lifting Bracket

Accessory

Sheet Metal
Screw

Содержание 2SA13 Series

Страница 1: ...lation of this appliance must conform to the requirements of the National Fire Protection Association the National Electrical Code ANSI NFPA No 70 latest edition in the United States the Canadian Elec...

Страница 2: ...THE UNIT as claim may be denied Check the unit rating plate to confirm specifications are as ordered Limitations The unit should be installed in accordance with all national and local safety codes Lim...

Страница 3: ...roper operation and service Refer to Table 1 for the minimum clearances to combustibles as well as minimum clearances necessary for servicing and proper unit operation In the U S units may be installe...

Страница 4: ...0 6 7 6 6 When connecting electrical power and control wiring to the unit waterproof type connectors must be used so that water or moisture cannot be drawn into the unit during normal operation CAUTIO...

Страница 5: ...0 90 C MIN WIRE POWER WIRING 24V CONTROL WIRING NEC CLASS 2 TYPICAL WIRING CONNECTION 1 PHASE GROUND SCREW THERMOSTAT OUTDOOR UNIT THERMOSTAT OUTDOOR UNIT GROUND SCREW POWER WIRING 200 230 3 60 460 57...

Страница 6: ...common venting system are not in operation 1 Seal any unused openings in the common venting system 2 Visually inspect the venting system for proper size and horizontal pitch and determine there is no...

Страница 7: ...ng air blower is controlled by a timing circuit in the blower control Timings are not adjustable There is no blower on delay after a call for heating or cooling Blower off delay is 90 seconds after th...

Страница 8: ...nd outdoor fan and vent motors are permanently lubricated and require no maintenance Outdoor Coil Dirt and debris should not be allowed to accumulate on the outdoor coil surface or other parts in the...

Страница 9: ...R R R XFMR C FUSE Y A15 BLOWER GRN RED BLU BLU YEL BLU W1 W2 CAN BE USED TO STAGE ELECTRIC HEAT ACCESSORY ON 15 20KW MODELS 5 7 5 10KW HEATER ACCESSORIES FUNCTION OFF W1 ONLY BLK BLK WHT P 1 P 2 P 4 P...

Страница 10: ...and excludes all other warranties express or implied The warrantor does not authorize any person to provide any other warranty or to assume for it any further obligation in connection with the warran...

Отзывы: