INSTALLATION 

INSTRUCTIONS FOR 

WIRELESS SENSOR AND 

REPEATER KITS 

 TEMPERATURE / RELATIVE HUMIDITY

SENSOR

CATALOG # 21L07

WIRELESS REPEATER

CATALOG # 21L09

Table of Contents

Shipping and Packing List

 ...........................................2

Overview........................................................................3

Sensor (21L07) ..............................................................5

Sensor – Power Options ..................................................................6

Sensor – S-Bus Wired Installation Setup .........................................6

Sensor – Wired Standalone / NCP Setup ........................................6

Sensor – Operation with BACnet Network (M3/M4 ONLY) ............12

Sensor – Wiring Troubleshooting ...................................................14

Sensor – Wireless Installation Setup .............................................15

Sensor – Wireless Standalone ......................................................16

Sensor – Placement and Confirming Location (Test)

 ....................17

Sensor – Wireless Checkout / Troubleshooting .............................18

Sensor – Signal Strength Alert Indication ......................................18

Sensor – Low Battery Indication ....................................................18

Sensor – After Hour Override (AHO) .............................................18

Sensor – Data Verification

 .............................................................19

Sensor – Network Removal and Reset  .........................................19

Repeater (21L09).........................................................20

Repeater – 24VAC Line Power ......................................................20

Repeater – Wireless Installation Setup ..........................................20

Repeater – Signal Strength Alert Indication ...................................21

Repeater – Placement and Confirming Location (Test)

 .................21

Repeater – Network Removal and Reset ......................................22

Repeater and Sensor Placement Requirements......23

FCC Compliance Statement ......................................26

FCC RF Exposure Information  .................................26

Содержание 106924-01

Страница 1: ...Wireless Installation Setup 15 Sensor Wireless Standalone 16 Sensor Placement and Confirming Location Test 17 Sensor Wireless Checkout Troubleshooting 18 Sensor Signal Strength Alert Indication 18 Sen...

Страница 2: ...adjustment alteration service or maintenance can cause personal injury loss of life or damage to property Installation and service must be performed by a licensed professional installer or equivalent...

Страница 3: ...aters can be used per rooftop unit Powered by external 24VAC only Used in wireless application only Locking captive screw Wireless Temperature Relative Humidity Sensor 21L07 TMP RH After hours overrid...

Страница 4: ...ors and Repeaters Connects to the Lennox CORE Unit Control ler via the wireless gateway W4 Pairs with a simple button press requires physical access Used for installation of wireless sensors and repea...

Страница 5: ...nsor Buttons and Indicators Figure 2 Wireless Sensor Configuration Factory Defaults Label NOTE Changed switch settings only take af fect after a sensor power reset Remove 24VAC or battery power after...

Страница 6: ...red Installation Setup S Bus connections can be used with M1 8 IMC M2 M3 and M4 Unit Controllers The sensor can be used in the following configurations By itself with a controller Wired Standalone In...

Страница 7: ...nfiguration on page 8 for wiring connection detail example RTU BUS Address 2 S BUS OPERATION IN STANDALONE MODE SENSOR BUS Address 2 NOTE Wireless sensor S Bus address MUST match RTU S Bus address DRA...

Страница 8: ...le 100 aluminum shield with strain wire with Teflon jacket Recommend Lennox catalog numbers 94L63 27M19 68M25 or Belden Type 88761 or equivalent Drain Wire Drain Wire Drain Wire Drain Wire Drain Wire...

Страница 9: ...h S BUS setup to change the unit S BUS address 2 Set S1 switch 6 for Mode to the ON position to enable STAND ALONE or OFF factory de fault for NETWORK BAS 3 Set S2 switch 3 Operation Mode to ON for wi...

Страница 10: ...te on the M3 Unit Controller screen to Setup Network Integration b Select L CONNECTION and select SAVE c Enter the S Bus address and select SAVE d Select the Control Mode as Room Sensor then select SA...

Страница 11: ...s Address 2 S BUS OPERATIONS WITH BACNET WIRED NOTE Use 22AWG 1 twisted pair shielded cable 100 aluminum shield with strain wire with Teflon jacket Recommend Lennox catalog numbers 94L63 27M19 68M25 o...

Страница 12: ...ON for wired S BUS mode 4 Connect sensor and RTU controller using rec ommended wire two conductor twisted pair shielded 22AWG See Figure 6 BACnet Wiring Configuration on page 11 for further details 5...

Страница 13: ...COEXIST to 1 then select SAVE d Navigate on the screen to Setup Net work Integration e Select L CONNECTION and select SAVE f Enter the S BUS Address and select SAVE This should match the S BUS Ad dres...

Страница 14: ...Network Source as YES then select SAVE u Set Occupied Blower Mode as Auto Cycling Auto Continuous1 2 3 and select SAVE v Select Backup Mode as None Wired Thermostat Return Air Backup and then select...

Страница 15: ...ady completed this step proceed to step 3 Select Adding and wait for the adding process to com plete 2 Click Add node on the Network Nodes screen This triggers the CORE Service App to scan for new sen...

Страница 16: ...enu and select Network Integration under Setup b Select the Network Setup Wizard c Select S Bus Wireless Sensor under Network Setup Wizard and select Next d Leave the S Bus address in its current sett...

Страница 17: ...ignal Indicator LED Description Off 3 Blinks Battery is good and sensor is within range Sensor is good to install Blinking for 10 seconds 3 Blinks Sensor is within range but battery power is low Repla...

Страница 18: ...successfully it will communicate with the RTU If the signal strength is weak the Signal Strength LED indictor will be ON for 10 seconds Sensor Low Battery Indication The Battery LED will blink for 10...

Страница 19: ...e Sensor will appear se lect Yes to proceed 4 Press and hold the beacon button for two sec onds to remove the node sensor from the BLE mesh network 5 Enter the sensor name on this screen and select Pr...

Страница 20: ...rvice App and go to the RTU Menu Network Integration Wireless Sensor Network Setup Wireless Sensor Network Provision Sensor Network Network Nodes 1 Click Add Node on the Network Nodes screen This trig...

Страница 21: ...owered wireless sensor that is already connected to the BLE network to the desired location 2 Hold the beaconing button for five seconds and release 3 Observe the status of the signal strength LED see...

Страница 22: ...ess Sensor Network Setup 1 Select the relay to remove 2 Select Remove Relay at the bottom of the screen 3 The Remove Relay screen will appear select YES 4 Press and hold the beacon button for two seco...

Страница 23: ...sor A maximum of two repeater hops are supported ROOT TOP UNIT BLE ANTENNA INSTALLED IN RETURN AIR SECTION OF RTU INTERIOR WALLS Typical Construction Dry Wall ROOF Typcial construction Corrugated Stee...

Страница 24: ...Y 24VAC REPEATER OR SENSOR WITH EXTERNAL 24VAC POWER MAXIMUM DISTANCE BETWEEN RTU M4 W4 AND REPEATER IS 80 FEET MAXIMUM PENTRATION OF 1 ROOF 1 CEILING FLOOR AND TWO INTERIOR WALLS TYPICAL HOP 1 MAXIMU...

Страница 25: ...CEILING FLOOR AND TWO INTERIOR WALLS TYPICAL HOP 1 MAXIMUM DISTANCE BETWEEN REPEATER TO REPEATER OR AND SENSOR IS 40 FEET SENSOR BATTERY POWERED MAXIMUM DISTANCE BETWEEN REPEATER TO REPEATER OR SENSO...

Страница 26: ...se harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio o...

Страница 27: ...27...

Страница 28: ...28...

Отзывы: