Lennox Hearth Products MPD-3530CNE-B Скачать руководство пользователя страница 19

19

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS  •  MERIT

®

 PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45)  •  CARE AND OPERATION INSTRUCTIONS

ACCESSORY COMPONENTS

Digital Wall Thermostat

The wall thermostat kit provides temperature control 

for optimum comfort.

Fireplace Shipping Weights/Volumes

Cat. 

No.

Model

Ship. 

Weight

Ship.

Volume

H7785

MPDR-3328CNM-B

98 lb.

 13.1 cu. ft.

H7786

MPDR-3328CPM-B

98 lb.

 13.1 cu. ft.

H7787

MPDR-3328CNE-B

98 lb.

 13.1 cu. ft.

H7782 MPDT-3328CNM-B

98 lb.

 13.1 cu. ft.

H7783 MPDT-3328CPM-B

98 lb.

 13.1 cu. ft.

H7784 MPDT-3328CNE-B

98 lb.

 13.1 cu. ft.

H0804 MPD-3530CNM-B

113 lb.

 15.8 cu. ft.

H7789 MPD-3530CPM-B

113 lb.

 15.8 cu. ft.

H1939 MPD-3530CNE-B

113 lb.

 15.8 cu. ft.

H0805

MPD-4035CNM-B

147 lb.

 20.2 cu. ft.

H7790

MPD-4035CPM-B

147 lb.

 20.2 cu. ft.

H1940

MPD-4035CNE-B

147 lb.

 20.2 cu. ft.

H0805

MPD-4540CNM-B

160 lb.

 23.0 cu. ft.

H7790

MPD-4540CPM-B

160 lb.

 23.0 cu. ft.

H1940

MPD-4540CNE-B

160 lb.

 23.0 cu. ft.

Standard Remote Control System 

The  Model  RCL  (Standard)  Remote  Control 

System  features  a  simple  ON/OFF  control 

function for the fireplace. Includes a hand-held 

transmitter, a remote receiver with wall-mount 

coverplate, and all required hardware to install 

the unit. The remote receiver can be wall- or 

hearth-mounted.

Remote Control System (Standard) 

H0249            RCL

Deluxe Remote Control System 

The  Model  RCL-T  (Deluxe)  Remote  Control 

System  has all of the features of the standard 

system along with an added easy-to-read LCD 

screen that provides access to many enhance-

ments, including battery power level indicator, 

timer, mode of operation, thermostatic display 

with room temperature in either F° or C°, flame 

indicator, and clock. Fully programmable, the 

Model RCL-T allows for command over nearly 

all operational and temperature variables using 

the hand-held remote control transmitter.

Remote Control System (Deluxe) 

H0251  RCL-STAT

Touch-Up Paint (Black) Kit 

90L73 

 TPK-B

Touch-Up Paint Kit

Repair of minor scratches and discoloration of 

the appliance painted surfaces may be accom-

plished with the touch-up paint kit.

ON/OFF Wall Switch Kit 

85L87 

FWSK

Rocker Switch Kit 

 

80L41                    FRS 

Unit-Mountable ON/OFF Rocker Switch Kit 

(Millivolt systems only)

The rocker switch may be used to provide ON/

OFF operation as an alternative to the optional 

wall switch. The rocker switch installs directly 

in the gas valve mounting bracket (millivolt gas 

valve-equipped fireplaces only).

Forced Air Blower Kits:
  Single Speed 

80L84 

FBK-100

  Variable Speed with  

 

 

    wall-mountable switch 

80L85 

FBK-200

  Variable Speed with  

 

  

    unit-mountable switch 

80L86 

FBK-250

Forced Air Blower Kit

The FBK-100 blower assembly provides con-

stant-velocity forced-air circulation. 
The FBK-200 blower assembly provides vari-

able-speed forced-air circulation and includes 

a wall-mountable variable-speed switch. 
The FBK-250 blower assembly provides vari-

able-speed forced-air circulation and includes 

a unit-mountable variable-speed switch.

(FBK-200 Models Only)

Wall Thermostat Kit, White 

H4635 

 DWTK

ON/OFF Wall Switch Kit

The ON/OFF wall switch may be used to control 

the  operation  of  the  fireplace  burner  as  an 

alternative to the optional unit-mountable ON/

OFF rocker switch. Install the wall switch in a 

convenient location near the fireplace.

Содержание MPD-3530CNE-B

Страница 1: ...N TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE...

Страница 2: ...Gas Pressure Requirements 7 Orifice Sizes 7 Burn In Period 7 Operation Care of Your Appliance 8 Gas Controls Access 8 Variable Flame Adjustment 9 Maintenance 10 Front Glass Enclosure Panel Removal and...

Страница 3: ...Lisez la section Informations importantes relatives la s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para e...

Страница 4: ...jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maiso...

Страница 5: ...manera 1 Identifique el interruptor o el termostato de pared quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode...

Страница 6: ...removed cracked or broken These fireplaces are vented gas appli ances Do not burn wood or other material in these appliances This appliance is only for use with the type of gas indicated on rating pl...

Страница 7: ...inlet and OUT for the manifold side The control valves have a 3 8 10mm NPT thread inlet and outlet side of the valve refer to Figures 1 and 2 Propane tanks are at pressures that will cause damage to...

Страница 8: ...ation of millivolt and electronic gas con trol systems is different Before lighting and operating your appliance determine whether you have a millivolt or electronic appliance The gas controls can be...

Страница 9: ...om combustible materials gasoline and other flammable liquids 6 Remember Millivolt appliances have a con tinuous burning pilot flame Exercise caution when using products with combustible vapors H I LO...

Страница 10: ...t exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged Homeowner must contact a qualified service technician at once if any abnormal condition is obse...

Страница 11: ...erate only when the front glass enclosure panels are installed Generally the front glass enclosure panel should not be re moved except to gain access to the components within the firebox Removing Glas...

Страница 12: ...e individual logs as shown in Figures 7 and 8 Logs should be placed in the order shown All logs that have notches to fit over the grate tines should be positioned with these notches directly against t...

Страница 13: ...he firebox with the log s notches directly over the brackets Position the right log log no 3 by inserting the pin from the rear log into the hole on its upper end Place the left log and then the small...

Страница 14: ...d in the order shown Position the rear log on the brackets at the rear of the firebox with the log s notches directly over the brackets Position the right log log no 3 by inserting the pin from the re...

Страница 15: ...he individual logs as shown below Logs should be placed in the order shown Position the center log on the burner first then place the glowing embers as shown in Figure 6 Place the rear log both the ri...

Страница 16: ...opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are not impinging...

Страница 17: ...is normal turn the ON OFF control unit mountedorremoteswitch depending on your application to the OFF position 5 Reinstall the lower control access panel then proceed to finish the installation Milliv...

Страница 18: ...NTED ON OFF SWITCH OR OPTIONAL WALL SWITCH OR OPTIONAL THERMOSTAT OR OPTIONAL REMOTE RECEIVER PILOT ASSEMBLY OPT BLOWER Junction Box White Green Red Black Neutral Side of Receptacle Tab Intact Green G...

Страница 19: ...attery power level indicator timer mode of operation thermostatic display with room temperature in either F or C flame indicator and clock Fully programmable the Model RCL T allows for command over ne...

Страница 20: ...A s t i K l e n a P e c a F n a e l C o N l e d o M o N g o l a t a C o N l e d o M 8 2 3 3 D P M 7 4 M 6 2 C M 3 3 D A R 0 3 5 3 D P M 6 3 L 8 8 2 C 5 3 D A R 5 3 0 4 D P M 7 3 L 8 8 2 C 0 4 D A R 0...

Страница 21: ...M 8 2 3 3 9 0 L 8 9 B P 3 3 R V L 2 8 0 L 8 9 S B 3 3 R V L 2 D P M 0 3 5 3 5 0 L 6 9 B P 5 3 R V L 2 9 0 L 6 9 S B 5 3 R V L 2 D P M 5 3 0 4 6 0 L 6 9 B P 0 4 R V L 2 0 1 L 6 9 S B 0 4 R V L 2 D P M...

Страница 22: ...l a t a C o N l e d o M d e h s i l o P s s a r B d e h s u r B s s e l n i a t S 8 2 3 3 D P M 0 1 L 8 9 B P 3 3 B E 1 1 L 8 9 S B 3 3 B E 0 3 5 3 D P M 7 6 K 6 9 B P 5 3 B E 9 4 L 8 8 S B 5 3 B E 5...

Страница 23: ...Antique Brass H0934 APD40C 40 Arch Pane Doors Black MPD4035 H0935 APD40TI 40 Arch Pane Doors Textured Iron H0936 APD40SP 40 Arch Pane Doors Satin Pewter H0937 APD40AB 40 Arch Pane Doors Antique Brass...

Страница 24: ...ter SUGK35SP H3569 SLGK35C 35 Sunrise Lower Grille Kit Black H3571 35 Sunrise Lower Grille Kit Satin Pewter SLGK35SP H3573 SUGK40C 40 Sunrise Upper Grille Kit Charcoal H3575 40 Sunrise Upper Grille Ki...

Страница 25: ...rtment fireplace logs and burner area Refer to Figures 10 MPD 3328 11 MPD 3530 or12 MPD 4035 4540 onpage16and verify the flame pattern and height displayed by the appliance conforms to the picture Fla...

Страница 26: ...ck up Pilot should remain lit If it goes out repeat steps 5 through 9 If knob does not pop up when released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO T...

Страница 27: ...tement La veilleuse devrait rester allum e Si elle s teint r p tez les tapes 5 8 inclusivement Si la manette ne se soul ve pas d elle m me lorsqu on la rel che arr ter et appeler imm diatement un tech...

Страница 28: ...ol valve to ON Do not force OPERATING INSTRUCTIONS 1 If applicable Set the thermostat to lowest setting Turn wall on off switch unit mounted on off switch or remote control switch OFF 2 Turn OFF all e...

Страница 29: ...cette tiquette S il n y a pas d odeur de gaz passez l tape suivante INSTRUCTIONS DE MISE EN MARCHE 1 Si applicable R glez le thermostat la temp rature la plus basse Tournez l interrupteur murale l int...

Страница 30: ...re is properly connected replace ignitor POSSIBLE CAUSES Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 14 on page 17 Check burner orifice for stoppage and remov...

Страница 31: ...er Thermostat Wiring 2 CHECK START NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected Measure Voltage At Valve HSI El...

Страница 32: ...59 1 24M59 1 10 Grate Assembly H6526 1 H6526 1 H6314 1 H6314 1 11 Orifice Main Burner Nat Gas 39L66 1 60J80 1 24M10 1 18L40 1 11 Orifice Main Burner LP Gas 99K78 1 19L52 1 21L01 1 37G00 1 12 Bag Of Em...

Страница 33: ...ENNOX HEARTH PRODUCTS MERIT PLUS DIRECT VENT GAS FIREPLACES MPD33 35 40 45 CARE AND OPERATION INSTRUCTIONS Replacement Parts 4 7 1 11 5 40 12 6 42 3 8 9 40 45 40 45 14 15 9 33 35 33 35 8 20 21 10 40 4...

Страница 34: ...ox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distrib...

Отзывы: