background image

5

LENNOX HEARTH PRODUCTS  •  MONTEBELLO

® 

 SEE-THROUGH DIRECT-VENT GAS FIREPLACES  (LSM40ST-N / LSM40ST-P)  •  CARE AND OPERATION INSTRUCTIONS

HOMEOWNER’S INSTRUCTIONS: ATTACHING “SAFETY-IN-OPERATION” WARNINGS

SAFETY LABEL DIAGRAMS  /  DIAGRAMAS DE ETIQUETAS DE SEGURIDAD  /  DIAGRAMMES DES ÉTIQUETTES DE SÉCURITÉ

Figure A 

Remote

Off

On

PRG

ATTACHING SAFETY-IN-OPERATION  

WARNINGS

Your  fireplace  has  been  furnished  with  safety 

instruction labels that are to be affixed to the opera-

tion and control points of the fireplace.  A safety 

instruction label should be affixed to the receiver 

wall switch plate where the fireplace is turned on 

and  off  (See 

Figure  A

)  and  the  remote  control 

handheld  transmitter  (

Figure  B

).    The  warnings 

should already have been put in place when the 

fireplace initial set-up was completed.  If they are 

not affixed at these spots, locate the multi-lingual 

adhesive  labels  provided  with  these  instructions 

and proceed as follows:
1.  Locate the wall receiver that controls the fire-

place (verify the switch operates the fireplace by 

turning it on and off).  Clean the wall receiver 

plate thoroughly to remove any dust and oils. 

Affix the label to the surface of the plate of the 

wall receiver  that controls the fireplace (

Figure 

A

).  Choose the language primarily spoken in the 

home. 

2.  Locate the remote control transmitter and clean 

it thoroughly to remove any dust and oils.  Affix 

the label to the surface of handheld transmitter 

(

Figure  B

).    Choose  the  language  primarily 

spoken in the home. 

3.  If you are unable to locate the labels, please call 

Lennox Hearth Products or your nearest Lennox 

Hearth  Products  dealer  to  receive  additional 

safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit 

LENNOX HEARTH PRODUCTS
1-800-9-LENNOX

Note: English is red text on clear label. French and 

Spanish are white text on black label.

APPOSITION DES MISES EN GARDE RELATIVES  

à LA SÉCURITÉ D’UTILISATION

Votre  foyer  a  été  livré  avec  des  étiquettes  de 

sécurité  qui  doivent  être  collées  à  côté  des 

dispositifs  de  contrôle  du  foyer.    Une  étiquette 

de  sécurité  devrait  être  collée  sur  la  plaque 

du  récepteur  mural  contrôlant  l’allumage  du 

foyer  (voir 

Figure  A

)  et  sur  le  boîtier  de 

la télécommande (

Figure B

).  Les mises en garde 

auraient dû être collées au moment de l’installation  

initiale du foyer.  Si ce n’est pas le cas, prenez les 

étiquettes adhésives multilingues fournies avec ces 

instructions et procédez comme suit:
1.  Repérez le récepteur mural qui contrôle le foyer 

(vérifiez que l’interrupteur contrôle le fonction-

nement du foyer en le faisant basculer de Marche 

à Arrêt, et vice-versa).  Nettoyez soigneusement  

la plaque du récepteur mural pour éliminer la 

poussière et les traces de graisse ou d’huile. 

Collez l’étiquette sur la surface de la plaque du 

récepteur  mural  qui  contrôle  le  foyer (

Figure 

A

).  Choisissez la langue qui est principalement 

parlée dans la résidence du propriétaire. 

2.  Repérez  la  télécommande  et  nettoyez-la 

soigneuse ment pour éliminer la poussière et les 

traces de graisse ou d’huile.  Collez l’étiquette 

sur le boîtier de la télécommande (

Figure B

).  

Choisissez  la  langue  qui  est  principalement 

parlée dans la résidence du propriétaire. 

3.  Si vous ne trouvez pas les étiquettes, veuillez  

appeler  Lennox  Hearth  Products  ou  votre 

distribu teur  Lennox  Hearth  Products  local 

pour  recevoir  gratuitement  des  étiquettes 

supplémentaires.
Étiquettes de remplacement, n° cat. H8024 

LENNOX HEARTH PRODUCTS
1-800-9-LENNOX

Remarque : Le texte anglais est rouge sur un 

support transparent. Le texte français et espagnol 

est blanc sur un support noir.

COLOCACIóN DE ADVERTENCIAS DE 

SEGURIDAD EN OPERACIóN

Su  chimenea  incluye  etiquetas  de  instrucciones 

de  seguridad  que  deben  colocarse  en  los 

puntos  de  operación  y  control  de  la  chimenea. 

Se  debe  colocar  una  etiqueta  de  instrucciones 

de  seguridad  en  la  placa  del  interruptor  de 

pared  del  receptor  desde  el  cual  se  enciende 

y  se  apaga  la  chimenea  (ver  la 

Figura  A

) 

y en el transmisor de control remoto (

Figura B

)

Las  advertencias  ya  deben  haberse  colocado 

cuando  se  completó  la  instalación  inicial  de  la 

chimenea. Si no están colocadas en estos lugares, 

encuentre  las  etiquetas  adhesivas  multilingües 

proporcionadas con estas instrucciones y prosiga 

de la siguiente manera:
1.  Identifique el receptor de pared que controla la 

chimenea (verifique que el interruptor opera la 

chimenea encendiéndola y apagándola). Limpie  

bien la placa del receptor de pared para quitar el 

polvo y aceite. Pegue la etiqueta en la superficie 

de la placa del receptor de pared que controla la 

chimenea (

Figura A

).

 

Seleccione el idioma que 

más se habla en la casa. 

2.  Identifique el transmisor de control remoto y  

límpielo  bien  para  quitar  el  polvo  y  aceite. 

Pegue la etiqueta en la superficie del transmisor 

(

Figura  B

).  Seleccione  el  idioma  que  más  se 

habla en la casa. 

3.  Si  no  puede  encontrar  las  etiquetas,  sírvase 

llamar a Lennox Hearth Products o al distribuidor  

de Lennox Hearth Products más cercano para 

recibir etiquetas de instrucciones de seguridad 

adicionales gratuitas. 
Juego de etiquetas de repuesto - Nº de cat. 

H8024 

LENNOX HEARTH PRODUCTS
1-800-9-LENNOX

Nota: La etiqueta en inglés es transparente con 

texto rojo. Las etiquetas en francés y español son 

negras con texto blanco.

Figure B

f i r e - p a r t s . c o m

Содержание LSM40ST-N

Страница 1: ...SEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT...

Страница 2: ...in Operation Warnings 5 Appliance Installation Service and Maintenance Notices 6 Appliance Operation Notices 6 Warranty Information 6 General Information 7 Inputs and Efficiencies 7 Gas Pressure Requ...

Страница 3: ...5 Lisez la section Informations importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para...

Страница 4: ...s jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la mais...

Страница 5: ...nt du foyer en le faisant basculer de Marche Arr t et vice versa Nettoyez soigneusement la plaque du r cepteur mural pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur...

Страница 6: ...and to replace any part of the control system and any gas control that has been under water Thesefireplacesaredesignedassupple mentalheaters Therefore itisadvisable to have an alternate primary heat s...

Страница 7: ...lve identified IN for the inlet and OUT for the manifold side see Figure 1 on Page 8 The control valve has a 3 8 10 mm NPT thread inlet and outlet side of the valve These appliances must be isolated f...

Страница 8: ...s are fitted with an ON OFF rocker switch that when toggled switches from intermittent ignition to a standing pilot see Figure 1 WARNING Young children should be carefully supervised when they are in...

Страница 9: ...witch in the Remote posi tion press the ON OFF Key on the Transmitter The Transmitter display will show all active Icons on the screen At the same time the Receiver connects to the gas valve coil and...

Страница 10: ...simplybytogglingthe switchlocatedinthecontrolcompartment refer to Figure 1 on Page 5 To save energy switch to intermittent mode To have a standing pilot which will help startup in the winter by warm i...

Страница 11: ...Embers Volcanic Stone and Logs Carefully follow placement instructions on Pages 13 15 All logs should fit onto cor responding pins and or log stoppers This will ensure a proper flame and safe combusti...

Страница 12: ...asket surface must be clean free of irregularities and seated firmly b Position the door in front of the firebox opening with the top of the door held away from the fireplace see Figure 8 c Lower the...

Страница 13: ...over the surface of the burner in the areas shown in Figures 10 and 11 Note To prevent flame impingement and soot do not use more ember material than necessary c For best glowing effect replace ember...

Страница 14: ...r Log B FIREBOX ACCESSORIES PARTS Cat No Model Description H8312 PGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone Table 5 LOG SET Item Description Item Description A Log Center D Log Top Rig...

Страница 15: ...finger Rest the other end of the log on the Landing on Center Log A Figure 18 10 See Figure 18 Place hole on underside of Top Left Log E over pin on Center Log A 9 Place groove on underside of Top Rig...

Страница 16: ...dy that does not soot the shutter opening must be adjusted between these two extremes Burner Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to...

Страница 17: ...minimum shutter setting is designed into the venturi by four 1 16 inch tabs If the flame appears weak or sooty as described on the previous page adjust the air shutter until proper flame appear ance...

Страница 18: ...8 LSM40ST P 382 lb 51 25cu ft ORDERING Replacement parts A complete parts list is found at the end of this manual Use only parts supplied from the manufacturer Withpropercareandmaintenance yourappli a...

Страница 19: ...7 AKM LSM Andirons Mission H2228 AKC LSM Andirons Classic Touch Up Paint Kit Repair of minor scratches and discoloration of the appliances black painted surfaces may be accomplished with the touch up...

Страница 20: ...reate a barrier to prevent direct contact with the hot glass The screen panel affixes directly to the front glass enclosure panel Dual Arch Screen Kits Cat No Model Description H5051 DASK LSM40 2 Dual...

Страница 21: ...ervice is to be performed TO TURN OFF GAS TO APPLIANCE OPERATING INSTRUCTIONS WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL IN...

Страница 22: ...E L APPAREIL INSTRUCTIONS DE MISE EN MARCHE AVERTISSEMENT QUICONQUE NE RESPECTE PAS LA LETTRE LES INSTRUCTIONS DANS LA PR SENTE NOTICE RISQUE DE D CLENCHER UN INCENDIE OU UNE EXPLOSION ENTRA NANT DES...

Страница 23: ...firebox for signs of blockage or obstruction Look for any signs of dislocation or deteriorationoftheventcomponents reconnectorreplaceasnecessary Appliance Checkout Qualified Service Technician Perfor...

Страница 24: ...cuit breakers to ensure power is on to the fireplace 2 The main burner does not light and the igniter is sparking A Gas is not reaching the fireplace Check the gas supply and gas shutoff valves B Loos...

Страница 25: ...3 3 Log Set H7994 1 4 Enclosure Glass Door H2281 2 5 Spring Latch Assembly H2274 2 6 Burner Assembly H7996 1 9 Access Plate H8013 1 10 Gasket Access Plate H8012 1 11 Gas Line Tubing H8001 2 12 Connect...

Страница 26: ...GH DIRECT VENT GAS FIREPLACES LSM40ST N LSM40ST P CARE AND OPERATION INSTRUCTIONS Replacement Parts ILLUSTRATION Circled numbers correspond to Replacement Parts List on previous page 1 2 4 18 25 27 3...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO SEE THROUGH DIRECT VENT GAS FIREPLACES LSM40ST N LSM40ST P CARE AND OPERATION INSTRUCTIONS Notes fire parts com...

Страница 28: ...nted in U S A 2011 Lennox Hearth Products P N 506025 05 Rev C 05 2011 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Lennox Hearth Products reserves the right to make changes at any time without noti...

Отзывы: