Burner Orifi ce Sizes 

Elevation 0-4500 feet ( 0-1372 meters)

Model
Series

Natural

Gas

drill size 

(inches)

Propane

Gas

drill size (inches)

LMDVT-3328
LMDVR-3328

#45 (.082") 

*

39L66 •

1.2 mm (.048") 

*

99K78 •

LMDV-3530

#44 (.086") 

*

60J80 •

#55 (.052") 

*

19L52 •

LMDV-4035

#37 (.104") 

*

24M10 •

1/16" (.0625")

*

21L01 •

* Standard size installed at factory
•  Part /Cat. Number

Table 7

Inlet Gas Supply Pressure 

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.0" WC

(1.24 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 4

Burn-in Period

During the fi rst few fi res of this appliance there 
will be some odor due to the curing of the 
paint and burning off of lubricants used in the 
manufacturing process. 

Depending on your use, the burn-in period may 
take a few hours or a few days.  

KEEP YOUR HOUSE WELL VENTILATED 
DURING THE CURING PROCESS.  THE ODOR 
AND HAZE EMITTED DURING THE CURING 
PROCESS CAN BE QUITE NOTICEABLE AND 
MAY SET OFF A SMOKE DETECTOR.

If an optional blower is installed, Do not turn it 
on during the Burn-In period. 

A white fi lm may develop on the glass front 
during the fi rst few fi res as part of the curing 
process.  The glass should be kept clean during 
the fi rst two weeks of use to prevent the fi lm from 
baking on (making it very diffi cult to remove).  
See 

Cleaning Glass 

on 

Page 6

.

These appliances and their individual shut-off 
valves 

must be disconnected

 from the gas 

supply piping system during any pressure 
testing of that system at pressures 

greater 

than

 1/2 psig (3.5 kPa)

.

These appliances must be isolated from the 
gas supply piping system (

by closing their 

individual manual shut-off valve

) during any 

pressure testing of the gas supply piping 
system at test pressures equal to or 

less than 

1/2 psig (3.5 kPa).

At the time of installation, it must be determined 
if the appliance needs to be derated. Contact 
your local gas supplier for deration requirements 
for your area.

Deration -

 At higher elevations, the amount of 

BTU fuel value delivered must be reduced by 
either using gas that has been derated by the gas 
company or by changing the burner orifi ce to a 
smaller size as regulated by the local authorities 
having jurisdiction and by the (USA) National 
Fuel Gas Code NFPA 54/ANSI Z223.1 - latest 
edition or, in Canada, the CAN1-B149.1 and .2 
codes - latest edition. 

Gas Pressure - 

Tables 4, 5 and 6

 show the appliances' gas 

pressure requirements.

Manifold Gas Supply Pressure

(millivolt models)

Fuel #

Low

High

Natural 

Gas

(Lo) 2.2" WC

(.55 kPa)

(Hi) 3.5" WC

(.87 kPa)

Propane

(Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 5

Manifold Gas Supply Pressure 

(electronic models)

Fuel #

Fixed

Natural Gas

3.5" WC

(.87 kPa)

Propane

10.0" WC

(2.49 kPa)

Table 6

Test gauge connections are provided on the 
front of the millivolt gas control valve, identifi ed 
IN for the inlet and OUT for the manifold side 
(see 

Figures 4 or 5 

on 

Page 5)

.  A 1/8" NPT 

Test gauge connection is provided at the inlet 
and outlet (manifold) ports on the electronic gas 
control valve (see 

Figure 3

 on 

Page 5)

.

Orifi ce Sizes -  Sea Level to High Altitude
(All Models): 

These appliances are tested and 

approved for installations at elevations of 0-4500 
feet (0-1372 meters) above sea level using the 
standard burner orifice sizes (marked with an 
"*" in 

Table 7)

.  

Gas Controls/Control Compartment 
Access

The gas controls can be found behind the control 
compartment access door. 

Removing Control Compartment Door:

Open the door by  gently liftint it upward until the 
hook catches on boths sides clear the locating 
slots. Then pull door out to remove.

On millivolt systems, the piezo igniter, HI/LO 
fl ame adjustment knob, and pilot and main 
gas OFF/ON control knob are located below 
the glass panel enclosure. The gas valve for 
electronic systems is also located below the 
glass enclosure panel. See 

Figure 1.

Reinstalling Control Compartment Door:

To reinstall, insert the hook catches on each side 
of the door into the corresponding slots in the 
control compartment opening, then gently push 
forward and slide down until it locks in place.

Figure 1 

OPENING CONTROL
COMPARTMENT DOOR

OPERATION AND CARE OF YOUR 
APPLIANCE

The standard controls for appliance operation 
are located behind the panel below the appli-
ance front glass enclosure panel (see 

Figure 

1

).

  Optional control switches are also available 

(see 

Page 14 

Remote Wall Switch, Remote 

Control or Wall Thermostat).

Operation of millivolt and electronic gas con-
trol systems are different. Before lighting and 
operating your appliance determine if you have 
a millivolt or electronic appliance. Familiarize 
yourself with the gas control valve that your 
appliance uses. Refer to 

Figure 1 

for access 

to the gas control valve. 

Control Valve

Lower Control 
Compartment Door

Lift the Lower Control 
Compartment Door 
up and pull out to 
remove.

Up

Out

Hook Catch

Содержание LMDTV-3328CNM

Страница 1: ...ACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will retain...

Страница 2: ...manual For assistance or additional information consult a qualified installer service agency or the gas supplier SAFETY WARNIING INFORMATION WARNING Thesefireplacesareventedheat ers Do not burn wood...

Страница 3: ...uction Page 3 General Information Page 3 Gas Controls Access Page 4 Operation Care of Your Appliance Page 4 Variable Flame Adjustment Page 5 Maintenance Page 6 Front Glass Enclosure Panel Removal and...

Страница 4: ...test edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Propa...

Страница 5: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Страница 6: ...improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the Va...

Страница 7: ...ERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the flame...

Страница 8: ...ogs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested for le...

Страница 9: ...VolcanicStoneandLogsintheorder shown here 1 through 6 and per the instructions onPage8 A E B C D Vermiculite Volcanic Stone Embers DO NOT PLACE EMBERS OVER GAS SLOTS 1 2 3 4 5 6 The2notchesonlogbottom...

Страница 10: ...rrespond to photos InstalltheEmbers Vermiculite VolcanicStoneandLogsintheorder shownhere 1through6 andper theinstructionsonPage8 D C E A B 1 2 3 4 5 6 Vermiculite Volcanic Stone DONOTPLACEEMBERSOVERGA...

Страница 11: ...uidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are not impinging on any of the logs If the log set is properly positioned and a sooting condi...

Страница 12: ...flame appearance is achieved 4 Leave the control knob off pilot on in the ON position and the burner OFF ON switch OFF remote switches if applicable 5 When satisfied that the burner flame ap pearance...

Страница 13: ...tch CAUTION Label all wires prior to discon nection when servicing con trols Wiring errors can cause improper and dangerous appli ance operation Figure16 Electronic Wiring Diagram Honeywell Showing Bl...

Страница 14: ...installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL Standard...

Страница 15: ...rass H0950 SD40C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design...

Страница 16: ...ariable Speed with Wall Switch 36 Pack H0543 FBK 250 36 Blower Kit Variable Speed with Thermo Snap Switch 36 Pack ref Form 750 028M 750 029M Variable Speed Wall Switch Provides variable speed control...

Страница 17: ...s are available in two styles These hoods are designed to be fitted to the glass viewing sides of the appliance In addition to providing an aesthetically pleasing appearance to your appliance installa...

Страница 18: ...your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair ma...

Страница 19: ...un commutateur lectrique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagni...

Страница 20: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Страница 21: ...pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mu...

Страница 22: ...oo many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service...

Страница 23: ...itch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote...

Страница 24: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Страница 25: ...Lennox Nameplate Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT H1657 1 88J53 1 13 Piezo Igniter w wire 91K94 1 91K94 1 14 Pi...

Страница 26: ...26 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE REPLACEMENT PARTS 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMDV 4035 LMDVT 3328 LMDVR 3530...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE NOTES...

Страница 28: ...N 875 028M REV D 05 2006 LennoxHearthProductsreservestherighttomakechangesatanytime withoutnotice in design materials specifications prices and also to discontinue colors styles and products Consult y...

Отзывы: