NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

START

CHECK

• Turn Off Gas Supply.

• Ensure Valve Switch Is In ON Position.

• Disconnect Control Harness.

• Set Thermostat To Call For Heat.

• Check for proper volt-

age at control harness  
(see insert A).  Voltage 
should be 24V   between 
thermostat or pressure 
switch and 24V common 
and 24V hot.

NO

•  Line voltage power
•  Low voltage transformer
•  Limit controller
•  Thermostat
•  Wiring

                      YES

• Plug control harness into 

valve.  Wait for internal check 
delay.

 • Igniter warms up and glows 

red. 

NO

 • With pilot burner cable con-

nected, measure voltage at 
valve HSI element output.  24V 
nominal.  (See insert B)

NO

•  Replace valve.

                         YES

                      YES

•  Replace igniter/fl ame rod 
    assembly.

                         YES

• Turn on gas supply.   
• Pilot burner lights.

NO

•  Check that pilot gas is fl owing.  Wait 

to ensure pilot gas tubing is purged.  
Recycle call for heat if necessary.

NO

•  Replace valve.

                         YES

                      YES

•   Measure voltage between 24V hot and 

24V common leads to valve control.  
Must measure at least 19.5 VAC with 
igniter powered (see insert A).  To 
identify proper lead, this check must 
be done with the valve control con-
nected and igniter powered.

NO

•  Check transformer and    

line volt supply.

                         YES

•    Replace Pilot Assembly.

•  Main valve opens and main 

burner lights.

NO

•  Check that pilot fl ame makes good 

contact with pilot burner fl ame rod.

•    Check for good electrical connection 

through the pilot tubing.

•   If both of the above are good, replace 

igniter/fl ame rod assembly.

                      YES

                         YES

•  System Is okay.

•    Cycle thermostat off and back on.

   

Igniter will cycle off and 

back on once during the 90 
second ignition trial.  All 
voltage measurements must 
be taken while the igniter is 
powered.

 

      

When measuring voltage 

at connections, use care 
to ensure terminals are 
not damaged.

•    Main burner lights.

NO

 •  Replace valve.

Insert A

End View of Control Harness Connector

24 Volt

Common

24 Volt Hot

24 Volt 

Switched

Check For Damaged or Missing
Terminals in Connector

Insert B

Igniter Terminals

1

2

2

1

2

1

TROUBLESHOOTING PROCEDURE - ELECTRONIC IGNITION SYSTEM

Содержание LMDTV-3328CNM

Страница 1: ...ACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will retain...

Страница 2: ...manual For assistance or additional information consult a qualified installer service agency or the gas supplier SAFETY WARNIING INFORMATION WARNING Thesefireplacesareventedheat ers Do not burn wood...

Страница 3: ...uction Page 3 General Information Page 3 Gas Controls Access Page 4 Operation Care of Your Appliance Page 4 Variable Flame Adjustment Page 5 Maintenance Page 6 Front Glass Enclosure Panel Removal and...

Страница 4: ...test edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Propa...

Страница 5: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Страница 6: ...improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the Va...

Страница 7: ...ERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the flame...

Страница 8: ...ogs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested for le...

Страница 9: ...VolcanicStoneandLogsintheorder shown here 1 through 6 and per the instructions onPage8 A E B C D Vermiculite Volcanic Stone Embers DO NOT PLACE EMBERS OVER GAS SLOTS 1 2 3 4 5 6 The2notchesonlogbottom...

Страница 10: ...rrespond to photos InstalltheEmbers Vermiculite VolcanicStoneandLogsintheorder shownhere 1through6 andper theinstructionsonPage8 D C E A B 1 2 3 4 5 6 Vermiculite Volcanic Stone DONOTPLACEEMBERSOVERGA...

Страница 11: ...uidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are not impinging on any of the logs If the log set is properly positioned and a sooting condi...

Страница 12: ...flame appearance is achieved 4 Leave the control knob off pilot on in the ON position and the burner OFF ON switch OFF remote switches if applicable 5 When satisfied that the burner flame ap pearance...

Страница 13: ...tch CAUTION Label all wires prior to discon nection when servicing con trols Wiring errors can cause improper and dangerous appli ance operation Figure16 Electronic Wiring Diagram Honeywell Showing Bl...

Страница 14: ...installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL Standard...

Страница 15: ...rass H0950 SD40C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design...

Страница 16: ...ariable Speed with Wall Switch 36 Pack H0543 FBK 250 36 Blower Kit Variable Speed with Thermo Snap Switch 36 Pack ref Form 750 028M 750 029M Variable Speed Wall Switch Provides variable speed control...

Страница 17: ...s are available in two styles These hoods are designed to be fitted to the glass viewing sides of the appliance In addition to providing an aesthetically pleasing appearance to your appliance installa...

Страница 18: ...your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair ma...

Страница 19: ...un commutateur lectrique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagni...

Страница 20: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Страница 21: ...pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mu...

Страница 22: ...oo many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service...

Страница 23: ...itch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote...

Страница 24: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Страница 25: ...Lennox Nameplate Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT H1657 1 88J53 1 13 Piezo Igniter w wire 91K94 1 91K94 1 14 Pi...

Страница 26: ...26 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE REPLACEMENT PARTS 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMDV 4035 LMDVT 3328 LMDVR 3530...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE NOTES...

Страница 28: ...N 875 028M REV D 05 2006 LennoxHearthProductsreservestherighttomakechangesatanytime withoutnotice in design materials specifications prices and also to discontinue colors styles and products Consult y...

Отзывы: