Lennox Hearth Products Elite LBC-3824 Скачать руководство пользователя страница 20

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

20

Lennox Hearth Products reserves the right to make changes at any time, without notice, in
design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.

Printed in U.S.A. © 2001 by LENNOX HEARTH PRODUCTS

P/N  850,003M  REV.  G  01/2010

INSTALLATION COMPONENTS
CONTINUED

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

1110 West Taft Avenue
Orange, CA  92865

Forced Air Kit

12M73

LFAK-2000

Cold Climate Kit

63L63

FTF10-CCK1-LD

Chase Termination

96L21

FTF10-CTT

Arch Type Termination

96L23

FTF10-ATT

Variable Speed
Wall Switch

045571H

VSWS

Firestop Attic Shield
(Canada Only)

63L68

FTF10-FSAS

Offset/ Return
Package (30

°

)

63L23

FTF10-ES30

Chase Termination
(Square)

63L52

FTF10-CT2

Combination
Offset/Return Elbow

63L34

FTF10-OR15

Содержание Elite LBC-3824

Страница 1: ...beginning your installation Do not alter or modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fire...

Страница 2: ...as a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your distributor 16...

Страница 3: ...re Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in accordance with codes such as the BOCA Basic National Codes the Standard Me chanicalCodeandtheUniformBu...

Страница 4: ...ed for safety and the reduction of heat loss Chimney Height The total height of your completed fireplace system from the surface the fireplace rests on to the chimney top must not exceed 80 24 4 and m...

Страница 5: ...be certain 1 Estimate the total weight of the fireplace system including chimney and surround ma terials such as brick stone etc to be in stalled Shippingweightsforthefireplacemay be found on page 18...

Страница 6: ...7 IMPORTANT UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS FIGURE 10 BE REMOVED OR MODIFIED NOR MAY YOU NOTCH THE HEADER TO FIT AROUND OR BE INSTALLED LOWER THAN THE SPACERS THE HEADER MAY BE IN...

Страница 7: ...15 Figure 16 Figure 14 Note All framing dimensions calculated for 1 2 dry wall at the fireplace face If sheathing the chaseorfinishingwithotherthicknessmaterials calculations will need to be made FRA...

Страница 8: ...ing or roof above Drive a nail through the ceiling or roof frombelowtomarkposition Markandcutahole intheceiling aroundthenail Figure20 Then plumb from ceiling or roof directly above the cut hole to de...

Страница 9: ...int Check each section by pulling up slightly from the top to ensure proper engage ment before installing succeeding sections If the flue has been installed correctly it will not separate when tested...

Страница 10: ...chimney system Install the Model FTF10 S4 stabilizer by fitting inner section down into respective section of proceeding flue pipe and locking outer stabi lizer section into place over the outer chimn...

Страница 11: ...be at least 2 above this reference point In all cases the chimney cannot be less then 3 above the roof at the edge of the chimney The 2 in 10 rule is necessary in the interest of safety but does not...

Страница 12: ...Figure 29 3 The effective heights of the components are The Fireplace 48 3 8 FTF10 12 10 1 4 FTF10 18 16 1 4 FTF10 36 34 1 4 FTF10 CTDTM Termination 13 FTF10 CT1 Termination 12 to 18 FTF10 CT2 Termin...

Страница 13: ...hes Feet Inches 12 18 36 MM M 461 38 5 0 1 13 11722 11 72 465 38 9 2 0 13 11824 11 82 471 39 3 1 1 13 11976 11 98 479 39 11 0 0 14 12179 12 18 489 40 9 1 0 14 12433 12 43 495 41 3 0 1 14 12586 12 59 4...

Страница 14: ...of FTF10 A B Offset Height Offset Return FTF10 S4 Chimney Sections Offset Height Inches Inches Elbow Set Stabilizer 12 18 36 mm mm 4 15 1 0 0 0 0 102 400 9 24 1 0 1 0 0 229 622 12 29 1 0 0 1 0 305 756...

Страница 15: ...WHERE IT COULD BE BLOCKED BY SHRUBS SNOWDRIFTS ETC NEVERLOCATEAIRINLET IN A GARAGE OR IN ANY AREA WHERE THERE IS ANOTHER FUEL BURNING APPLIANCE OR PRODUCTS EMITTING COMBUSTIBLE GASES SUCH AS PAINT GA...

Страница 16: ...cold air could enter the room Surrounding materials must be caulked where it meets the black metal facing of the fireplace to avoid cold air intrusion Use noncombus tible caulking material only on fir...

Страница 17: ...lle 54 1 85 64 5 8 Face brick 9 00 111 10 71 10 3 4 Common brick 5 00 20 5 95 6 Cement mortar 5 00 20 5 95 6 Ceramic tile 12 5 08 14 88 14 7 8 Marble 11 09 13 10 13 1 8 Table 1 Methods of Determining...

Страница 18: ...der the hearth extension refer to Figures 6 7 A wall shield is required where a continuous perpendicular side wall is within 12 of the fireplace opening Figure 46 Use a 36 W x 36 H wall shield constru...

Страница 19: ...Allowed in Shaded Area 1 25mm 18 457mm Minimum Distance to Protected Side Wall LBR Models Figure 50 4 17 32 115mm 30 Combustible Materials Allowed in Shaded Area 1 2 13mm 12 305mm Minimum Distance to...

Страница 20: ...EARTH PRODUCTS P N 850 003M REV G 01 2010 INSTALLATION COMPONENTS CONTINUED NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 1110 West Taft Avenue Orange CA 92865 Forced Air Kit 12M73 LFAK 2000 Cold Climate K...