WARNING: ELECTRONIC MODELS OF
THESE APPLIANCES ARE EQUIPPED
WITH A THREE-PRONG (GROUNDING)
PLUG UTILIZED IN CONNECTING THE
ELECTRONIC COMPONENTS TO THE
JUNCTION BOX IN THE LOWER COM-
PARTMENT.  THIS GROUNDING PLUG
PROVIDES PROTECTION AGAINST
SHOCK HAZARD AND SHOULD BE
PLUGGED DIRECTLY INTO THE PROP-
ERLY GROUNDED THREE-PRONG RE-
CEPTACLE.  DO NOT CUT OR REMOVE
THE GROUNDING PRONG FROM THE
PLUG.

SIT And Honeywell Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced,
it must be replaced with

 

Type AWM105

°

C – 18 GA. wire.

Thermopile

TH

TP

TH

TP

*TWIST WIRES “A” AND “B” TOGETHER TO OPERATE UNIT

SOLELY BY MANIPULATING THE GAS VALVE CONTROL KNOB;

OR CONNECT WIRES TO  OPTIONAL ON/OFF SWITCH OR WALL

SWITCH OR THERMOSTAT TO OPERATE UNIT.

*OPTIONAL ON/OFF SWITCH,

 WALL SWITCH, THERMOSTAT

OR REMOTE CONTROL RECEIVER

A

B

Figure 43

*Narrow (2-1/8 inch Wide)

J-Box Required

See Figure 11 on page 8

for Optional Electrical

Inlet Knockout Location

*Field-Provide

Junction Box

 and Duplex

Receptacle

Optional J-Box/Outlet Box

(Left Side Shown)

Figure 44

Note: The tab connecting the receptacles of
the outlet box must be  broken in FBK-100 and
FBK-200 blower kit applications.

Step 4. FIELD WIRING

Refer to Section A for millivolt appliances and
Section B for electronic appliances. The gas
valve is set in place and pre-wired at the
factory on both models.

1. Route a 3-wire 120Vac 60Hz 1ph power
supply to the appliance junction box.

2. If the factory-provided outlet/junction box
at the right rear of the fireplace is being used,
remove the outlet box from the junction box by
removing two screws.

3. Connect the power supply wires  (including the
ground supply wire)
 as shown in 

Figures 45 or 46.

(If the field-provided J-box/outlet box is being used,
all of the outlet box wiring must be field-provided.)

4. Locate and install a low voltage (24V) wall-
mounted switch or thermostat (both field-
provided)in the desired location.

5. Connect the low voltage wire, located in-
side the control compartment, to the wall-
mounted switch or thermostat.

Note: The supplied 15 feet of 2 conductor wire has
one end of each conductor connected to the gas
valve circuit and the other end of each conductor
placed loose inside the control compartment.

6. Insert the control circuit plug into the
unswitched receptacle of the outlet box.

7. After wiring is complete, mount the outlet
box to the J-Box.

A. SIT and Honeywell Millivolt Wiring
(See Figure 43) –

1. Select  any of the following optional con-
trols: appliance-mounted (rocker switch) or
wall-mounted  switch, thermostat, or one of the
optional remote control kits. If appliance-
mounted ON/OFF control is selected mount it in
the gas valve mounting bracket.

2. If wall-mounted ON/OFF control or thermo-
stat is selected mount it in a convenient location
on a wall near the fireplace.

3. Wire the control within the millivolt control
circuit  using the 15 feet of 2 conductor wire
supplied with the unit . Caution:  do not connect
the optional wall switch to a 120V power supply.

4. Alternatively, the appliance may be operated
without the use of the controls indicated in step 1,
solely  by manipulating the gas valve control knob.
In order to use this method, twist the free ends of
the two conductor wire (located inside the control
compartment) together as shown in 

Figure 43.

Note: The supplied 15 feet of 2 conductor wire has
one end of each conductor connected to the gas
valve circuit and the other end of each conductor
placed loose inside the control compartment.

Note: The gas valve-mounted ON/OFF switch  is
shown in Figure 45  or  46. It is integral with the
gas valve and should be set to the ON position.

Step 5.

 

WIRING - OPTIONAL FORCED AIR

BLOWER KIT

FBK-100, FBK-200 and FBK250 Kits
(See  
Figure 45 for FBK-100, FBK-200 and
Figure 46 for FBK-250 wiring) -

An electrical outlet box (receptacle) is factory -
provided for the installation of the FBK-100FBK-
200 and FBK-250
 forced air blower kits. (An
optional field-provided outletbox/J-Box may also
be used.   Electrical power must be connected to
either of these receptacles in order to operate
these blowers. Install the blower kits according to
the installation instructions provided with the kits.

B. Electronic Wiring 

(See Figure 45 or 46) –

Note:  The electronic appliance must be con-
nected to the main power supply.

The junction box is located on the right side of
the appliance. It contains a factory installed
and wired outlet box (duplex receptacle). Also,
an optional field-provided junction box with
receptacle may be installed at the front of the
control compartment on either side of the
cabinet.

 See Figure 44. It will be held in place

by a conduit fitting and locknut (field-provided).

IMPORTANT: Ground supply wire must be
connected to the green wire attached to the
outlet receptacle's green ground screw.  See
Figure 45 or 46. Failure to do so will result in
a potential safety hazard. The appliance must
be electrically grounded in accordance with
local codes or, in the absence of local codes,
the National Electrical Code, ANSI/NFPA 70-
(latest edition). (In Canada, the current CSA
C22-1 Canadian Electrical Code.)

Содержание Direct Vent MPD-33 Series

Страница 1: ...850 014CF Ce manuel d installation est disponible en francais simplement en faire la demande Num ro de la pi ce 850 014CF s l e d o M t l o v i l l i M s l e d o M c i n o r t c e l E M N C 8 2 3 3 T...

Страница 2: ...ntsmanu facturedbySecurityChimneysInternationaland Z Flex Model GA Venting Systems listed to UL1777 and ULCS635 manufactured by Flex master Canada Limited These approved vent system components are lab...

Страница 3: ...rving a separate solid fuel burning appliance These heater rated appliances are intended for use as supplemental heaters only Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning are sim...

Страница 4: ...ble 2 APPLIANCE AND VENT CLEARANCES The appliance is approved with zero clearance to combustible materials on all sides as de tailed in Table 2 with the following exception When the unit is installed...

Страница 5: ...e and do not supersede local codes in any way Install vent according to local codes these instructions the current National Fuel Gas Code ANSI Z223 1 in the USA or the current standards of CAN CGA B14...

Страница 6: ...or securing the glass door Remove the door by tilting it outward at the bottom and lifting it up Set the door aside protecting it from inadvertent damage See Figure 53 on page 24 The fireplace should...

Страница 7: ...o t a l u g e r r e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e...

Страница 8: ...MPD 4540 Models Dimensions D and F occur when one 45 degree elbow is connected directly to the appliance collar MPD and MPDR units D E F A B MPD and MPDT units o N l e d o M A B C D E 8 2 3 3 T D P M...

Страница 9: ...3 8 1 5 4 6 1 1 1 6 2 8 7 4 3 6 1 7 7 1 9 3 9 3 6 1 m m 6 4 1 1 3 4 9 0 1 6 3 0 0 1 6 4 1 1 8 7 6 6 8 8 3 4 4 0 2 2 6 7 0 2 2 6 7 6 0 4 Step 3 INSTALL THE VENT SYSTEM General Information Theseinstruc...

Страница 10: ...ALL AND SECURELY TIGHTEN COVER PLATE SCREWS COULD RESULT IN LEAKAGE OF FLUEPRODUCTSINTOTHELIVINGSPACE VENTCOVERPLATEANDVENTSEALPLATE MUSTREMAINSECURELYINSTALLEDON UNUSED VENT COLLAR FAILURE TO DO SO C...

Страница 11: ...2 5 2 1 8 1 0 1 0 6 0 7 5 9 2 2 5 2 1 9 1 0 0 1 6 0 7 5 2 3 2 5 7 3 9 1 0 0 0 0 5 5 7 3 2 5 7 9 1 1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0...

Страница 12: ...nd number of elbows required Refer to Vertical Vent Figures and Tables on page 14 and 15 to select the type of vertical installation desired Vent sections are available in net lengths of 4 1 2 114 mm...

Страница 13: ...ction to align with the required direction of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possiblity of unlocking any of the previously connected ve...

Страница 14: ...ed then 4 feet mini mum V vertical vent will be required This table shows a 1 V to 2 H ratio For every 1 foot of V vertical you are allowed 2 feet of H horizontal run up to a maximum horizontal run of...

Страница 15: ...V1 Ceiling Firestop Spacer SV4 5VF Wall Firestop Spacer SV4 5HF When using Secure Flex use Firestop Spacer SF4 5VF When using Secure Flex use Firestop Spacer SF4 5HF Example If20feetof H horizontalven...

Страница 16: ...Push the vent component against the previous section until it fully engages then twist the component clockwise running the dimples down and along the incline channels until they seat at the end of th...

Страница 17: ...the telescopic vent section SV4 5LA as the last vent section For wall thicknesses greater than that shown in Figure 32 refer to Table 4 on page 18 This table lists the additional venting components ne...

Страница 18: ...level Note Secure Vent components rigid vent pipe and terminal are shown in the figures SecureFlexcomponents flexibleventpipeand terminal may also be used Note Two45degreeelbowsmaybeusedinplace ofone...

Страница 19: ...s meters meters H1 V H Wall Firestop Spacer SV4 5HF Ceiling Firestop Spacer SV4 5VF When using Secure Flex use Firestop Spacer SF4 5HF When using Secure Flex use Firestop Spacer SF4 5VF Example If 20...

Страница 20: ...feet of H horizontal run up to a maxi mum horizontal run of 20 feet An elbow is acceptable as 1 foot of vertical rise except where an elbow is the only vertical component in the system See Figure 35...

Страница 21: ...with the inlets of the four incline channels of the last vent sectionorcollar Pushontheadapteruntilitfully engages then twist the adapter clockwise run ning the dimples down and along the incline chan...

Страница 22: ...and Honeywell Millivolt Wiring See Figure 43 1 Select any of the following optional con trols appliance mounted rocker switch or wall mounted switch thermostat oroneofthe optional remote control kits...

Страница 23: ...G e t i h W l a r t u e N OPENING CONTROL COMPARTMENT DOOR The millivolt control valve has a 3 8 10 mm NPT thread inlet port The electronic control valve has a 1 2 13 mm NPT thread inlet port and is f...

Страница 24: ...he firebox floor to the door s vee flange Close both the latches securely Electronic Appliance Checkout To light the burner turn ON the optional remote wall switch and turn the gas control switch to t...

Страница 25: ...N 8 1 2 3 p o r P 2 1 3 1 Figure 54 The adjustment rod and associated adjustable air shutter is patented technology Flame ad justments can be made quickly and accurately to taste without the need of...

Страница 26: ...ent door Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements Note Combustible wall finish materials and or surround mat...

Страница 27: ...m 0 1 6 h c n i 4 2 n o i t c e S 3 7 L 7 7 6 3 L 5 4 V S t n e V m m 4 1 9 h c n i 6 3 n o i t c e S 4 7 L 7 7 8 4 L 5 4 V S t n e V m m 9 1 2 1 h c n i 8 4 n o i t c e S 5 7 L 7 7 A L 5 4 V S n o i...

Страница 28: ...x e l F r o f n i m r e T l a c i t r e V n o i t c e s r e t p a d A x e l F h t i w 2 1 2 1 r a l l o c t r o p p u s f o o r t n e v d i g i r f o d n a g n i h s a l f f o o r y l b m e s s a r a...

Страница 29: ...ecuring screws WARNING THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER S IN STRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORI...

Страница 30: ...re 61 s m e t s y S T I S t l o v i l l i M n o i s r e v n o C s a G e n a p o r P o T l a r u t a N s t i K s l e d o M e p y T t i n U o N g o l a t a C 8 2 3 3 T D P M 8 2 3 3 R D P M t l o v i l...

Страница 31: ...On Any Side Of The Hex Fitting b Attach manometer to the manifold side pressure test fitting and verify manifold pres sure reads 3 5 inches water column 0 87 kPa for natural gas and 10 0 inches water...

Страница 32: ...it Remove the slotted cap screw o ring pressure regulating adjusting screw and spring Retain all parts for possible later use Install new components from the kit Black cap and red spring for propane g...

Отзывы: