GLASS CARE

Glass Replacement

The glass used for the Brentwood™ LV fireplace 

is a high temperature ceramic glass (1,400° F / 

760° C).  If the glass breaks, it must be replaced 

with an identical ceramic glass.  Tempered glass 

or ordinary glass will not withstand the high 

temperatures of the Brentwood LV fireplace.  

Replacement glass should be purchased from a 

IHP dealer (see “Replacement Parts”, 

Page 25

).  

DO NOT OPERATE THE UNIT WITH CRACKED 

OR BROKEN GLASS. 

Glass Cleaning

The Brentwood LV fireplace is designed to 

keep the glass clean under normal operating 

conditions. If the Brentwood LV fireplace is 

operated continuously with the combustion air 

controls closed, the glass will tend to get dirty 

unless the fuel, firebox and glass are maintained 

at hot temperatures (see “Refueling For Best 

Performance”).  To clean the glass, there are a 

number of specially designed cleaners.  Your IHP 

dealer can recommend a suitable cleaner which 

is available in your area.  Regular household 

glass cleaners will not clean creosote. 

 Do not 

use abrasives such as steel pads, steel wool 

or oven cleaner as they will scratch the glass.
DO NOT USE CHEMICAL GLASS CLEANERS 

ON PAINTED SURFACES AS IT MAY CAUSE 

THE PAINT TO PEEL.
CAUTION : DO NOT ALLOW WINDOW CLEANER 

TO GET IN CONTACT WITH DOOR  OR PAINT 

ON FACADE OR DOOR.  ONCE CLOSED, 

CONTACT OF GLASS CLEANER WITH THE 

FIREPLACE FACADE CAN PROVOKE PAINT 

PEELING OFF.

If possible, you should choose a location where 

the chimney will pass through the house without 

cutting floor or roof joists (see fireplace dimen-

sions 

Page 11

).

Usually, no additional floor support is needed 

for the fireplace.  The adequacy of the floor 

can be checked by first estimating the weight 

of the fireplace system.  Weights are given in 

the appendix.  Note the floor construction and 

consult your local building code to determine 

if additional support is needed. 

The Brentwood LV fireplace may be installed 

directly on the floor or on a raised base (for 

proper guidelines, refer to “Hearth Extension 

Requirements”) and a minimum of 6’8” (2 m) 

measured from the base of the appliance to the 

ceiling is required.

When selecting the location, the chimney outlet 

position and the direction of the wind are impor-

tant factor affecting the chimney performance. 

To allow a maximum draft and to reduce wind 

turbulence, the chimney must:

•  Penetrate the highest part of the roof.

•  Be installed as far as possible of roof offsets, 

trees or any other obstructions that may 

cause wind turbulence and back drafts in 

the chimney.

•  The least amount of offsets (elbows) pos-

sible. 

NOTE:

 A maximum of 2 offsets is 

allowed.

Gasket Replacement

Remove the door from the unit (see 

Page 7

) 

and lay it on a clean unabrasive surface. To 

replace the gasket, first remove all of the old 

gasket and gasket cement.  Make sure that the 

surface is totally clean before applying new 

cement (a high temperature silicone caulking 

rated at 500° F [260° C] is suitable) or adhesion 

problems may result.  Apply gasket cement to 

the gasket channel and install the new gasket.  

This replacement part is available from your IHP 

dealer in the following dimensions:

FIREPLACE INSTALLATION

Locating The Brentwood LV Fireplace

The best location to install your fireplace is 

determined by considering the location of 

windows, doors, and the traffic flow in the room 

where the fireplace is located, allowing space 

in front of the unit for the hearth extension and 

the mantel, and taking into consideration the 

location of the hot air ducts (optional), outside 

air kit and chimney.  

Gasket

Length* Dimensions

Part No.

Around 

Glass

74

(1880)

3/16” x 1” 

(4.8 x 25.4)

PR-SR1685J

On Door 

Frame

77-3/4
(1975)

3/4 dia.

(19)

PR-SR1823O

Table 1                     

       * Inches (millimeters)

8

Marginal Location

Wind Direction

Location

Not

Recommended

Outside Air Intake

Facing the Wind

Location

Not 

Recommended

Location Recommended

Figure 6

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Содержание BRENTWOOD LV

Страница 1: ...The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appli ance Severe burns may result Carefully supervise children in the sam...

Страница 2: ...unat tended while it is burning WARNING Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufac...

Страница 3: ...nsult the local authorities to obtain your buildingpermitandcheckyourlocalbuilding codes Installthefireplaceonlyasdescribed in these instructions and using only IHP components This fireplace has been...

Страница 4: ...terials may overheat the fireplace causing damage to the unit a fire or even possibly ignit ing a chimney fire if the chimney is creosoted Burningunapprovedfuel resultinginexcessive pollutantsbeingemi...

Страница 5: ...ing to avoid smoking problems SMOKING CAUSES AND TROUBLESHOOTING Toreducethelikelihoodofsmokingwhenopen ing the door set the combustion air controls to the left before opening the door Your fireplace...

Страница 6: ...ior to Cleaning The Chimney Before starting to clean your chimney we recommend that you remove the top baffle to avoid creosote dust collection at the top of the baffle Follow these steps to set the t...

Страница 7: ...e door may need to be adjusted to be com pletelyairtight Thegaskets air tightnesscanbe adjustedusingtheadjustmentscrewlocatedon the right side of the fireplace facade An Allen key 1 8 not supplied wil...

Страница 8: ...t is needed The Brentwood LV fireplace may be installed directly on the floor or on a raised base for proper guidelines refer to Hearth Extension Requirements and a minimum of 6 8 2 m measured from th...

Страница 9: ...the clean face kit to allow hot air flow that wouldnormallycomeoutofthetoplouver ANY OTHER INSTALLATION MAY RESULT IN THE FIREPLACE OVERHEATING AND POTENTIALLY CAUSE A FIRE See Gravity Kit section on...

Страница 10: ...place must be covered with a non combustible material tile marble stone etc See Figures 9 and 10 Cold climate INSTALLATIONS Climates where temperatures will fall below 32 F 0 C The heating performance...

Страница 11: ...hoto graphs are not to scale consult installation instructions Product designs materials dimensions specifications colorsandpricesare subjecttochangeordiscontinuance without notice All framing dimensi...

Страница 12: ...4 m Level Outside Base Insulation Thermal Barrier Solid Continuous Surface NOTE It is recommended that the chase walls and floor be insulated in the same manner using the same insulation as the rest...

Страница 13: ...an not overlay on the fireplace front black steel faceofthefireplace seeFigures16and17 Non combustible materials such as brick stone or ceramic tile can project in front of and onto the fireplace faci...

Страница 14: ...stem forward of the Brentwood LV fireplace not flush it will be necessary to purchase two adjustable lengths H8951 When installing the double outlet system the hotairoutletscanbeinstalledinthesameroom...

Страница 15: ...henusing the double hot air outlet kit and blocking the upper louver of the fireplace CENTRAL FORCED AIR KIT NOT TESTED UNDER EPA CERTIFICATION The knock outs provided on the back and on the sides of...

Страница 16: ...must not draw air from the attic from the basement or garage D The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away from automobile exha...

Страница 17: ...reasesthelikelihoodofoperatingproblemssuch as low draft high rate of creosoting and poor start up characteristics Exterior chimneys are also prone to down drafting and flow reversal Installations whic...

Страница 18: ...en the roof and the flashing with roofing pitch see Figures 30 and 31 For sloping roofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using...

Страница 19: ...a plumb bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below...

Страница 20: ...13 16 122 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95...

Страница 21: ...1 8 x 30 3 4 45 283 mm x 518 mm 11 1 8 x 20 3 8 S 2100 HT6000 AC 6 dia 30 327 mm x 881 mm 12 7 8 x 34 11 16 30 380 mm x 972 mm 15 x 38 1 4 Table 5 Figure 36 Drywall Insulated Wall Insulated Wall Radia...

Страница 22: ...th the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY OFFSET SUPPORT ROOF SUPPORT ASHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6 1 m AC 6 dia 4...

Страница 23: ...ix it in place using the 3 metal screws supplied Figure 39 FIREPLACE 1 Clearance Insulated Elbow ASHT or HT6103 3 Screws Insulation Pad Cover High Temp Cement Firestop Tubinox or Projet SS Stainless S...

Страница 24: ...26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26ZR H8952 Optional installation accessories uNot tested...

Страница 25: ...2324 31 Cast iron log retainer bar PR SR2323 Blower 250 CFM for central forced air kit BISZY BISZY Blower variable speed control with decora tive wall plate for BISZY VRUW VRUW Thermo disk on off blow...

Страница 26: ...REPLACEMENT PARTS Brentwood LV 1 8 15 16 17 20 10 14 12 11 13 20 22 23 24 21 25 26 30 31 19 2 3 4 5 6 7 PA I N T 18 28 29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 26...

Страница 27: ...ated Wall Radiation Shield 30 6RSMI30 6RSMI30 Uninsulated Wall Radiation Shield 30 6RSM30 6RSM30 Attic Radiation Shield H0487 Roof Flashings Flat Roof Flashing 6FR 6FR 1 12 7 12 5 30 6FAR 6FAR 8 12 12...

Страница 28: ...No 6 Length 6 Dia 6LL6 6LL6 12 Length 6 Dia 6LL12 6LL12 24 Length 6 Dia 6LL24 6LL24 36 Length 6 Dia 6LL36 6LL36 48 Length 6 Dia 6LL48 6LL48 Adjustable Length 7 to 11 6 Dia 6L7A 6L7A Split Base Tee 6...

Страница 29: ...NOTES 29...

Страница 30: ...se only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repa...

Отзывы: