background image

Brentwood™ LV 

Item #

Description

Cat./Part No.

1

Baffle refractory (2 pieces)

PR-ISO2205

2

Back refractory

PR-SR2996

3

Right side refractory

PR-SR2997D

4

Left side refractory

PR-SR2997G

5

Bottom refractory

PR-SR2201

6

Front refractory, right side - ash lip

PR-SR2202D

7

Front refractory, left side - ash lip

PR-SR2202G

8

Secondary air tube

PR-SR2271

9

Bracket, secondary air tube lock

PR-SR2214

10

11

12

13

14

Facing:

          Top trim

          Bottom trim

          Top frame

          Left side frame

          Right side frame

PR-SR3033

PR-SR3020

PR-SR2995

PR-SR2994G

PR-SR2994D

15

Fireplace top

PR-SR2500

16

Fireplace left side

PR-SR2502

17

Fireplace right side

PR-SR2503

18

Fireplace back

PR-SR2499

19

Touch-up paint, aerosol, black metallic 

SBMB6309

H8159

20

Louvers, upper and lower (set of 2)

LOUVRECF

21

Complete door

PR-SR3003LV

22

Wooden door handle

PR-SR2856

23

Door handle rod and lock

PR-SR2855

24

Ceramic glass panel

PR-SR3004

25

Gasket, door, 77-3/4” (3/4” dia.)

PR-SR1823O

26

Gasket, glass, 74” (3/16” x 1”)

PR-SR1685J

27

Hinge assembly, fireplace and door 

PR-SR1933

28

Blower (heat activated on/off,  pre-wired)

UZY6

29

Snap Disc, Blower

VTU

30

Andiron (2)

PR-SR2324

31

Cast iron log retainer bar

PR-SR2323

---

Blower 250 CFM for central forced air 

kit, BISZY

BISZY

---

Blower variable speed control with decora-

tive wall plate for (BISZY), VRUW

VRUW

---

Thermo-disk, on/off blower control (for 

BISZY), VTU

VTU

---

Blower to flexible pipe adaptor, BISAVF

BISAVF

---

Backdraft damper, BISBD

BISBD

---

Fireplace to Flex adaptor and 2 clamps, 

BISAF

BISAF

REPLACEMENT PARTS - BRENTWOOD™ LV

Contact an IHP dealer to obtain any of these parts. Never use substitute 

materials not approved by IHP. Use of non-approved parts can result 

in poor performance and safety hazards.

CLEARANCE TO COMBUSTIBLES

The following clearances meet the minimum requirements for a safe 

installation:

Side wall: 

24” (610 mm) measured from the fireplace side.

Ceiling:

  6’ 8”  (2,032 mm) measured from the base of the fireplace.

Fireplace enclosure:

 

Bottom

:  0”

Side:

   0” to spacer

Back:

   0” to spacer

Top:

 Do not fill the space above the fireplace with any material (Except 

the wood framing.  See 

Page 11, Figure 11

).

Chimney:

  2” (50 mm)

Mantel: 

45”  (1143 mm) measured from the base of the fireplace.

SPECIFICATIONS

Cat. No.

Model

H8295

Brentwood™ LV

Product Reference Information

Weight

385 lbs 

Height

36”

Width

36”

Depth

24-1/2”

Firebox W x H x D - measured in front

22” x 11-3/4” x 12”

Chimney weight ASHT (6” dia)

6.25 lb per linear foot

Chimney weight AC (6” dia)

3.25 lb per linear foot

25

Содержание BRENTWOOD LV

Страница 1: ...The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appli ance Severe burns may result Carefully supervise children in the sam...

Страница 2: ...unat tended while it is burning WARNING Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufac...

Страница 3: ...nsult the local authorities to obtain your buildingpermitandcheckyourlocalbuilding codes Installthefireplaceonlyasdescribed in these instructions and using only IHP components This fireplace has been...

Страница 4: ...terials may overheat the fireplace causing damage to the unit a fire or even possibly ignit ing a chimney fire if the chimney is creosoted Burningunapprovedfuel resultinginexcessive pollutantsbeingemi...

Страница 5: ...ing to avoid smoking problems SMOKING CAUSES AND TROUBLESHOOTING Toreducethelikelihoodofsmokingwhenopen ing the door set the combustion air controls to the left before opening the door Your fireplace...

Страница 6: ...ior to Cleaning The Chimney Before starting to clean your chimney we recommend that you remove the top baffle to avoid creosote dust collection at the top of the baffle Follow these steps to set the t...

Страница 7: ...e door may need to be adjusted to be com pletelyairtight Thegaskets air tightnesscanbe adjustedusingtheadjustmentscrewlocatedon the right side of the fireplace facade An Allen key 1 8 not supplied wil...

Страница 8: ...t is needed The Brentwood LV fireplace may be installed directly on the floor or on a raised base for proper guidelines refer to Hearth Extension Requirements and a minimum of 6 8 2 m measured from th...

Страница 9: ...the clean face kit to allow hot air flow that wouldnormallycomeoutofthetoplouver ANY OTHER INSTALLATION MAY RESULT IN THE FIREPLACE OVERHEATING AND POTENTIALLY CAUSE A FIRE See Gravity Kit section on...

Страница 10: ...place must be covered with a non combustible material tile marble stone etc See Figures 9 and 10 Cold climate INSTALLATIONS Climates where temperatures will fall below 32 F 0 C The heating performance...

Страница 11: ...hoto graphs are not to scale consult installation instructions Product designs materials dimensions specifications colorsandpricesare subjecttochangeordiscontinuance without notice All framing dimensi...

Страница 12: ...4 m Level Outside Base Insulation Thermal Barrier Solid Continuous Surface NOTE It is recommended that the chase walls and floor be insulated in the same manner using the same insulation as the rest...

Страница 13: ...an not overlay on the fireplace front black steel faceofthefireplace seeFigures16and17 Non combustible materials such as brick stone or ceramic tile can project in front of and onto the fireplace faci...

Страница 14: ...stem forward of the Brentwood LV fireplace not flush it will be necessary to purchase two adjustable lengths H8951 When installing the double outlet system the hotairoutletscanbeinstalledinthesameroom...

Страница 15: ...henusing the double hot air outlet kit and blocking the upper louver of the fireplace CENTRAL FORCED AIR KIT NOT TESTED UNDER EPA CERTIFICATION The knock outs provided on the back and on the sides of...

Страница 16: ...must not draw air from the attic from the basement or garage D The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away from automobile exha...

Страница 17: ...reasesthelikelihoodofoperatingproblemssuch as low draft high rate of creosoting and poor start up characteristics Exterior chimneys are also prone to down drafting and flow reversal Installations whic...

Страница 18: ...en the roof and the flashing with roofing pitch see Figures 30 and 31 For sloping roofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using...

Страница 19: ...a plumb bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below...

Страница 20: ...13 16 122 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95...

Страница 21: ...1 8 x 30 3 4 45 283 mm x 518 mm 11 1 8 x 20 3 8 S 2100 HT6000 AC 6 dia 30 327 mm x 881 mm 12 7 8 x 34 11 16 30 380 mm x 972 mm 15 x 38 1 4 Table 5 Figure 36 Drywall Insulated Wall Insulated Wall Radia...

Страница 22: ...th the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY OFFSET SUPPORT ROOF SUPPORT ASHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6 1 m AC 6 dia 4...

Страница 23: ...ix it in place using the 3 metal screws supplied Figure 39 FIREPLACE 1 Clearance Insulated Elbow ASHT or HT6103 3 Screws Insulation Pad Cover High Temp Cement Firestop Tubinox or Projet SS Stainless S...

Страница 24: ...26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26ZR H8952 Optional installation accessories uNot tested...

Страница 25: ...2324 31 Cast iron log retainer bar PR SR2323 Blower 250 CFM for central forced air kit BISZY BISZY Blower variable speed control with decora tive wall plate for BISZY VRUW VRUW Thermo disk on off blow...

Страница 26: ...REPLACEMENT PARTS Brentwood LV 1 8 15 16 17 20 10 14 12 11 13 20 22 23 24 21 25 26 30 31 19 2 3 4 5 6 7 PA I N T 18 28 29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 26...

Страница 27: ...ated Wall Radiation Shield 30 6RSMI30 6RSMI30 Uninsulated Wall Radiation Shield 30 6RSM30 6RSM30 Attic Radiation Shield H0487 Roof Flashings Flat Roof Flashing 6FR 6FR 1 12 7 12 5 30 6FAR 6FAR 8 12 12...

Страница 28: ...No 6 Length 6 Dia 6LL6 6LL6 12 Length 6 Dia 6LL12 6LL12 24 Length 6 Dia 6LL24 6LL24 36 Length 6 Dia 6LL36 6LL36 48 Length 6 Dia 6LL48 6LL48 Adjustable Length 7 to 11 6 Dia 6L7A 6L7A Split Base Tee 6...

Страница 29: ...NOTES 29...

Страница 30: ...se only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repa...

Отзывы: