background image

1. Combustible material must be installed flush 

with the fireplace.  It may not project in front 

of and on the fireplace (i.e. the steel facade 

of the fireplace) (

Figure 14

).

2. Non-combustible materials such as brick, 

stone or ceramic tile may project in front of 

and onto the fireplace facing (

Figure 13

).

MANTEL & FACING

The  mantel  must  be  installed  at  least  56” 

(1143  mm)  above  the  base  of  the  fireplace 

(

Figure 13

).

Figure 13

  IMPORTANT

The facade must be removable 

once  installed.  The  facade  is 

designed to overlap any facing 

material installed on the front of 

the fireplace. If thicker material 

is installed, use the facade as a 

template and make sure it can be 

easily removed for servicing.

FACING

1

3

4

5

6

2

1

2

7

3

4

1.  Fireplace

2.  Front of fireplace

3.  Wood frame (2” x 3” min)

4.  Drywall 

5.  Tiles

6.  Rock board or other

7.  Brick

Fireplace Frame Section

(Top View)

Figure 12

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

...............

..........

Mantel

Rock Board 

or Other

Noncombustible 

Facing

56”

Drywall

2” X 3” Min.

Spacer

Mantel & Facing

(Side View)

Figure 15

Drywall

2” X 3” Min.

Spacer

Noncombustible Facing

Only non-combustible material 

should be superposed or project-

ing over the front of the fireplace.

Figure 14

50”

Min.

Fireplace Blower

The fireplace comes equipped with a heat acti-

vated blower. It is located in the bottom  of the 

fireplace, towards the back. It uses 120 V and 

must be connected to the main electrical circuit 

by a qualified electrician. For connection, use the 

electrical box supplied with the unit located on 

the bottom right corner of the fireplace.

If  you  wish  to  adjust  the  blower  speed,  the 

variable speed control (VRUW) provided must 

be installed in line with the wiring. Again, use 

a qualified electrician for installation.

If the blower requires servicing,

1- Remove the doors and decorative facade.

2- Remove the screw located below the blower 

motor that holds it to the back of  fireplace.

3- Pull the blower out of the unit through the 

square hole located in the front bottom right 

corner.  

HOT AIR DUCTING INSTALLATION

The Montecito Estate™ is approved for use with 

a Gravity Kit:

Gravity Kit

The gravity kit is designed for double hot air 

outlets and includes:    

(See 

Figure 16

)

  - 2 telescopic lengths  8” I.D.

  - 2  90º elbows  8” I.D.

  - 2 hot air outlet kits (grill and frames)  

- 2 adaptors

See Gravity Kit Accessories on 

Page 20

.

Only the blower available with the fireplace can 

be used with the gravity kit.

For safe installation, the gravity kit must meet 

the following requirements:

 

Minimum height*

  68”  (1,727 mm)

 

Maximum length  

 See 

Figure 17

*  The height of the louver must be measured 

from the base of the Montecito Estate to the 

middle point of the louver.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

10

Содержание 038M

Страница 1: ...HESE INSTRUCTIONS FOR FUTURE REFERENCE Listed to standards ULC S610 UL 127 Report No 304 7213 EPA Cert No 609 WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during oper...

Страница 2: ...re left partly opened smoke may be drawn into the room Use optional firescreen when doors are fully opened WARNING Usecarewhenselectingwindow treatments for windows located near the fireplace Avoid us...

Страница 3: ...Required Fireplace model MONTEST 7 diameterchimney Model SecureTemp S 2100 Nova Temp HT6000 Secure TempGX U S only or ACBI manufactured by Security Chimneys International only including Chimney lengt...

Страница 4: ...lburnveryintenselyus ing this method and may damage the firebox Medium Combustion This is the recommended mode of operating the Montecito Estate and should be the one normally used since it will depos...

Страница 5: ...g time will be between 6 8 hours and at this combustion rate the level of BTU s is at its lowest Building a Fire A To start a fire place several crumpled up ballsofnewspaperinthefirebox Placesmall dry...

Страница 6: ...he chimney WARNING When cleaning the fireplace the ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on...

Страница 7: ...s 1 400 F If the glass breaks or cracks it must be replaced with an identical ceramic glass Tempered glass or ordinary glass will not withstand the high temperatures of the Montecito Estate Replacemen...

Страница 8: ...1 A Frame the fireplace using 2 x 3 or heavier lumber B WARNING Combustible materials cannot be used in the space directly above the fireplace except for the studs above the fa cade that support the f...

Страница 9: ...3 4 705 mm J 66 3 8 1686 mm Notes Due to Lennox ongoing commitment to quality all specifications ratings and dimensions are subject to change without notice All framing dimensions calculated for 1 2 d...

Страница 10: ...It is located in the bottom of the fireplace towards the back It uses 120 V and must be connected to the main electrical circuit byaqualifiedelectrician Forconnection usethe electrical box supplied wi...

Страница 11: ...heat A furnace duct is only single wall and not double wall as is required for the Montecito Estate hot air exhaust 7 Use only Security Chimneys International grills and components as described in thi...

Страница 12: ...above or below floor level Makea4 1 4 110mm holeintheoutsidewallofthehouseatthechosen location From outside place the outside air register in the hole open side down and fasten the register to the wal...

Страница 13: ...are located on lower floors in the house such as in a basement in combination with an outside chimney are especially prone to flow reversal 2 The fireplace model MONTEST may be installed only with Se...

Страница 14: ...rsal support AC10SU 4 Put the roof flashing in place and seal the joint between the roof and the flashing with roofing pitch see Figures 25 26 For sloping roofs place the flashing under the upper shin...

Страница 15: ...uctions on Page 14 5 From below install a firestop See Figure 23a 6 A support XST or XSO must be used on the first 15 section 5 m 7 Continue with the regular installation ACBI Chimney 1 Install the fi...

Страница 16: ...mm 45 21 32 1160 mm 54 1 8 1375 mm B 17 9 16 446 mm 20 7 16 519 mm 24 5 8 625 mm 28 7 8 733mm 37 3 8 949 mm 42 1067 mm 44 3 4 1137 mm 49 1245 mm 59 9 32 1353 mm 61 3 4 1568 mm Chimney Elbow Offset Hei...

Страница 17: ...diation Shield Framing 2 x 3 Figure 29 Roof Support Note In cold areas it is recommended to protect the chimney in a insulated chase Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET...

Страница 18: ...t of supported chimney NOTE For the ACBI chimney a support section ACBI7SL must be used every 30 feet 9m or an universal support every 20 feet 6m instead of the universal roof support ST CHIMNEY MAXIM...

Страница 19: ...ill enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a 30 TUBINOX liner elbow can be easily slipped through 4 Slide...

Страница 20: ...ECMC H4855 Outside Air Kit included with fireplace Outside Air Coupler To Connect Outside Air UZI To Fireplace UZIAD UZIAD Outside Air Ducting includes 4 insulated flex x 10 long UZI UZI Gravity Kit G...

Страница 21: ...ashing Adjustable 30 45 includes spacer collar ACBI7FBR H3277 Misc Firestop ACBI7BF H3268 Radiation Shield ACBI7RS H3269 Attic Radiation Shield ACBI7RSA H3270 Telescopic Attic Radiation Shield ACBI7RS...

Страница 22: ...PR SR2417 Right Side Refractory Bricks Front PR SR2419 Left Side Refractory Bricks Back PR SR2416 Left Side Refractory Bricks Front PR SR2418 Bottom Refractory Brick PR SR2422 Wooden Door Handle PR SR...

Страница 23: ...NOTES 23...

Страница 24: ...ction which were not manufactured or supplied by LHP or for the labor necessary to install repair or remove such materials parts or construction All replacement or repair components will be shipped F...