background image

17

Mount the front cover as per the image above and make sure it is  
fitted correctly. 

In order to do so, allign and fit the top snap fastening, apply and main-
tain pressure on the top of the front cover while sliding the front cover 
over the bottom snap fastening.

11

Mount the front cover as per the image above and make sure it is 

 

fitted correctly. 

In order to do so, allign and fit the top snap fastening, apply and 

maintain pressure on the top of the front cover while sliding the 

front cover over the bottom snap fastening.

Содержание LNL-R50000-WR

Страница 1: ...Installation guide LenelS2 Readers 5000 Series Slimline Economy Installation guide Lenel Readers 5000 Series Slimline Economy...

Страница 2: ...on 12 VDC idle mode 35 mA Wiegand 12 VDC idle mode 35 mA peak draw 92 mA LED Bar setting low Backlight setting low OSDP 12 VDC idle mode 46 mA peak draw 114 mA LED Bar setting low Backlight setting lo...

Страница 3: ...represent the actual sizes and form of the components 3 1pc Installation plate 1pc Reader module with front plate 1pc Front cover 1pcs Terminal connector 10 pin 2pcs Installation screws 2pcs Screw plu...

Страница 4: ...4 20 cm In order to facilitate installation a cable length of 20 cm is recommended...

Страница 5: ...nsure that the installation plate is fixed in the correct direction i e the arrows pointing upwards 5 Ensure that the installation plate is fixed in the correct direction i e the arrows pointing upwar...

Страница 6: ...fect the tamper switch func tionality of the reader Countersunk screws should never be used 6 When installing directly to wall or door use the installation holes as picture describes If using other sc...

Страница 7: ...7 Make sure to place the terminal connector with the fastening screws facing towards you 7 Make sure to place the terminal connector with the fastening screws facing towards you P3 Black Socket...

Страница 8: ...232 RS232 Ground Power supply 9 12 VDC Description PIN Wiegand x x x x x x x P3 Black RS232 x x x x 8 1 Maximum wiegand cable length is 150 meters and requires a high quality shielded cable with minim...

Страница 9: ...rts a wire diameter from 20 to 24 AWG Requires twisted pair cable Step 1 Check the correct position of terminal that connects the RS232 RS485 converter to 5000 Series Slimline Economy reader then chec...

Страница 10: ...es need to be stripped for about 8 mm then inserted into the RS485 terminal of the RS232 RS485 OSDP converter 10 10 Step 2 The RS485 communication wires is stripped about 8 mm then inserted into the R...

Страница 11: ...ension of the spring during wire insert and needs to be placed without being taken out during placing or removing the wire 11 11 Step 3 Every time the RS485 communication wire is inserted into the RS2...

Страница 12: ...serted into the connection hole of the lower row of the converter after insert ing the wiring tool then the wiring tool has not been inserted well and needs to be taken out and re inserted 11 11 Step...

Страница 13: ...13 Step 5 After inserting the RS485 OSDP communication wire pull out the wiring tool 13 13 Step 5 After inserting the RS485 communication wire pull out the wiring tool...

Страница 14: ...follow the previous steps to properly connect the remain ing communication wires to the converter tallati Step 6 Then follow the previous steps to properly connect the remain ing communication wires...

Страница 15: ...recommended to connect the the wires to the terminal connectors before tightening the cable strip 16 16 Make sure no excess connection cable is left in between the reader module and the installation...

Страница 16: ...plate ensure that the reader pin header contact perfectly aligns with the terminal connector block 10 When installing the reader to the mounting plate ensure that the reader pin header contact perfec...

Страница 17: ...pressure on the top of the front cover while sliding the front cover over the bottom snap fastening 11 Mount the front cover as per the image above and make sure it is fitted correctly In order to do...

Страница 18: ...reader use the supplied fixing screw and fix it into the installation plate through the front cover 12 To secure the front cover to the reader use the supplied fixing screw and fix it into the install...

Страница 19: ...ds This will release the front cover without damaging the front cover and or the installation plate 13 Opening Tool reader housing part no LNL R50000 OT To open the reader first remove the fixing scre...

Страница 20: ...Overview programming of reader Setting the reader in programming mode see page 21 Resetting the OSDP secure channel see page 24 Changing authentication card see page 23 Configuring the reader see page...

Страница 21: ...and connection cable set part no LNL R50000 TOOL LNL R50000 TOOL UK or LNL R50000 TOOL US Pre initialized Authentication Card part no LNL C5000 PAC 17 1 Set the reader in programming mode see page 15...

Страница 22: ...no LNL C5000 PCC Configuring the reader Configuration Card part no LNL C5000 PCC 16 1 Set the reader in programming mode see page 15 2 Present the Configuration Card to the reader as shown Keep the ca...

Страница 23: ...AC Changing authentication card Change Authentication Card part no LNL C5000 PCAC 17 1 Set the reader in programming mode see page 15 2 Present the CHANGE Authentication Card to the reader as shown Ke...

Страница 24: ...lation mode Card to the reader as shown Keep the card within reading distance until the reader beeps and blinks in green The reader has now reset the secure channel encryption keys to installation mod...

Страница 25: ...25 Accessories LenelS2 Readers 5000 Series Slimline Economy...

Страница 26: ...Series card reader s back plate on uneven wall installations or similar environments To prevent deformation of the reader s back plate Stainless steel spacer plate Slimline spacer Stainless steel mou...

Страница 27: ...line spacer Matte black part no LNL R50000 SPSB Slimline spacer Matte white part no LNL R50000 SPSW 19 The distance plate can be used for example when installing readers in environments where the inst...

Страница 28: ...rt no LNL R50000 DPVPSB Slimline spacer for vandal protection Matte white part no LNL R50000 DPVPSW 20 Used to install readers on an area where additional cover is needed to hide old installation hole...

Страница 29: ...k part no LNL R50000 DP10SB Slimline Angled spacer 10 degrees Matte white part no LNL R50000 DP10SW 21 Used to increase accessibility as well as visibility of the keypad Distance plate angled 10 Sliml...

Страница 30: ...mline Slimline Angled spacer 33 degrees Matte black art nr LNL R50000 DP33SB 22 Used to increase accessibility as well as visibility of the keypad Recommended height is 900mm center of reader above th...

Страница 31: ...n Slim line Slimline Vandal protection Matte black part no LNL R50000 SPVPSB 23 The vandalization protection is an accessory that shields the reader and helps it withstand violence by absorbing and re...

Страница 32: ...used for covering up old installation holes Distance plate large Vandalization protection Slimline 24 A recommended combination when external wiring is needed together with the vandalization protecti...

Страница 33: ...pair of pliers to remove the plastic break off parts to fit your reader model 25 Climate Privacy protection Screws and screw plugs included with accessory Slimline and Standard Multi Weather Cover tra...

Страница 34: ...aning instructions Use compressed air in between the buttons to remove dust and dirt and after that Isopropyl alcohol can be used with a piece of fabric to rub in between the buttons and the reader ex...

Страница 35: ...SON OR ENTITY BUYING ITS PRODUCTS INCLUDING ANY AUTHORIZED DEALER OR AUTHORIZED RESELLER IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS More information on...

Отзывы: