background image

Page 1/15 

7November2022/Version 6 

LEM reserves the right to carry out modifications on its transducers, 

 

in order to improve them.

LEM International SA 

Route du Nant-d’Avril, 152

1217 Meyrin 

 www.lem.com

Current Transducer ITZ 2000-SBPR FLEX ULTRASTAB 

I

P M

 =  125 ... 2000 A

N° 88.36.98.100.0

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation 

between primary and secondary. Separate magnetic head and measuring electronics provides 

high flexibility.

Features

 

±10 V voltage output

 

● Closed loop fluxgate

 

Split design - separate head 
and rack electronics

 

Analog output on 15-pin D-sub female output connector

 

Status/interlock port on 9-pin D-sub male output connector

 

Secondary current monitoring on BNC connector

 

4 mm banana sockets for secondary current output

 

Full-featured indicator panel.

Advantages

 

Very high accuracy

 

● Excellent linearity

 

● Extremely low temperature drift

 

Wide frequency bandwidth

 

● High immunity to external fields

 

No insertion losses

 

Low noise on output signal

 

Low noise feedback to primary conductor.

Applications

 

Feedback element in high-precision, high-stability power 
supplies

 

Calibration unit

 

Absolute current standard reference

 

Test and calibration of current sources

 

● Current extender for power systems

 

● Differential current measurement on power line

 

Metrology applications.

Standards

EMC: 

 

EN 61000-6-2: 2019

 

EN 61000-6-3: 2007 + A1 (2011)

 

EN 61326-1: 2013

Safety: 

 

IEC 61010-1: 2010/AMD1: 2016.

Application Domains

 

Industrial

 

Laboratory

 

Medical.

Содержание ITZ 2000-SBPR FLEX ULTRASTAB

Страница 1: ...lock port on 9 pin D sub male output connector Secondary current monitoring on BNC connector 4 mm banana sockets for secondary current output Full featured indicator panel Advantages Very high accurac...

Страница 2: ...ce required cleaning by dry compressed air is authorized This transducer is a build in device whose hazardous live parts must be inaccessible after installation This transducer must be mounted in a su...

Страница 3: ...degree 2 Rated insulation RMS voltage reinforced insulation UNm V 1250 IEC 61010 1 conditions over voltage cat III pollution degree 2 RMS voltage for AC insulation test 50 60 Hz 1 min Ud kV 10 8 Impu...

Страница 4: ...230 V RMS PC W VA 48 104 Average Peak RMS noise current 0 10 Hz 4 Ino ppm 0 1 RMS noise current 0 10 kHz 4 2 RMS noise current 0 100 kHz 4 60 Re injected RMS noise on primary bus bar 0 100 kHz V 10 Te...

Страница 5: ...o improve them LEM International SA Route du Nant d Avril 152 1217 Meyrin www lem com ITZ 2000 SBPR FLEX ULTRASTAB Typical power consumption 0 10 20 30 40 50 60 2500 2000 1500 1000 500 0 500 1000 1500...

Страница 6: ...lit when the transducer head saturates due to excessive primary current 600 A 24000 A yellow LED These LEDs are lit when a transducer head with the corresponding full scale range is connected to the r...

Страница 7: ...Status Interlock signal outputs 9 pin D Sub male UNC 4 40 screw lock 8 Option A B These positions are for future expansion or customization not used 2 8 3 1 7 6 5 4 LEM International SA Route du Nant...

Страница 8: ...esent on the port each having two dedicated floating pins in the SUBD9 Male connector Collector C and Emitter E Status Interlock port wiring Depending on how each signal is wired it can be Active Low...

Страница 9: ...sducer head is not saturated High IP UC The primary current is higher than 105 of nominal full scale output 0 2 V The primary current is lower than 105 of nominal full scale output ACTIVE UC The prima...

Страница 10: ...ed off When the rack electronics temperature cools to approximately 60 C the measuring circuit is automatically re enabled and the status LED is again lit Over current protection Electrical specificat...

Страница 11: ...ansducer head description Connect the transducer head to the electronics rack using the supplied transducer head cable and mount the programming plug in the 25 pin D Sub connector on the transducer he...

Страница 12: ...gh Out 6 Ground 7 US Low Sense 8 US Low Out 9 Current out 10 Current out 11 Current out 12 US High Sense 13 US High Out 14 US Low Sense 15 US Low Out Connect both pins 1 and 9 pins 2 and 10 pins 3 and...

Страница 13: ...mount ITZ FLEX ULTRASTAB electronics Transducer head European Schuko CEE 7 7 and US Japanese mains cables 2 m each with three pole IEC C13 female connector Short plug for 4 mm banana terminals and 15...

Страница 14: ...nt d Avril 152 1217 Meyrin www lem com ITZ 2000 SBPR FLEX ULTRASTAB Optional Calibration can be separately ordered as per the table hereafter Calibration with certificate in ISO 17025 certificated lab...

Страница 15: ...odifications on its transducers in order to improve them LEM International SA Route du Nant d Avril 152 1217 Meyrin www lem com ITZ 2000 SBPR FLEX ULTRASTAB Dimensions Rack electronics in mm general t...

Отзывы: