1) Status of the time indication (based on the EBIX system):
3DXXXX invalid time information (in case of failure) or time adjustment within the
measurement period to more than two seconds
7FXXXX
valid time
Note: Time indication status of 38
XXXX isn’t supported according to EN50463:2017
anymore. Instead 3DXXXX will be recorded
2) Status of the energy indication (based on the EBIX system):
XX2EXX
replacement value, measured energy value does not exist
XX3DXX invalid energy indication (in case of failure)
XX7FXX valid (measured) energy value
3) Status of location information (based on the EBIX system):
XXXX2E no location information available (incorrect or no GPS receiver)
XXXX3D location uncertain, last reception of GPS information more than 15 seconds
before the entry of the load profile
XXXX7F
valid location information
•
C.5.3
Traction system (
“traction type flag” according to EN 50463-3:2017), which is a
combination of frequency and voltage detection.
A system is detected only when voltage and frequency match the expected
combination. E.g. detection of one parameter only or conflicting detections are flagged
as “undefined system”.
Traction type detection with bit code according to previous version (EM4TII) is available
on special request (register name: C.5.2).
Traction type detection is based on measurement on channel 1 and in case of ACDC-
configuration on channel 1 and 3
C.5.3 value
Meaning
00
Undefined, no System recognized
01
AC System 2: 25kV, 50Hz recognized
02
AC System 1: 15kV, 16.7Hz recognized
03
DC System 3: voltage 3000V recognized
04
DC System 2: voltage 1500V recognized
05
DC System 1: voltage 600V ... 750V
•
0.9.17 Location (latitude ± DD.XXXXX) at the end of the registration period with
±DD = degrees (positive: north, negative: south)
XXXXX = decimal degrees
•
0.9.18 Location (longitude ± DDD.XXXXX) at the end of the registration period with
±DDD = degrees (positive: east, negative: west)
XXXXX = decimal degrees
Note: Location output format has been changed according to the requirements of the
standard EN 50463:2017. The input format of coordinates according to NMEA0183 is still
accepted with the old format “DDMM.XXXX”
•
1.29.0 energy feed (delta value) of positive active energy
•
2.29.0 energy feed (delta value) of negative active energy
•
3.29.0 energy feed (delta value) of positive reactive energy
•
4.29.0 energy feed (delta value) of negative reactive energy