Press



to  position the function selector > on

 

ADD  1 CH

 and press 

⏎.

>ADD 1 CH

 PREAMP:  ON

To add a filter for two channels with two adjacent 

MUX press

and select 

ADD 2 CH.

 Press 

⏎ 

to 

confirm. Select the first channel with the



keys. 

The second channel will automatically appear in se-

cond position. Press 

⏎ 

to confirm.

> 5-> 5 L 65

 PREAMP:  ON

 >ADD 2 CH

  ADD 1 CH

> 9<>10 L 65

 PREAMP:  ON

CH DELETED

Position the function selector

on MUX filtering or 

MUX conversion using



then keep pressed 

⏎ 

for five seconds.

To activate the filtering function on a single MUX set 

the desired channel through the



keys and then 

press 

⏎ 

twice to confirm.

> 5-> 5 L 65

 PREAMP:  ON

To activate the filtering and conversion function on 

a single MUX set the desired input channel through 

the



keys and press 

  to  confirm.  Select  the 

output channel required for the conversion through 

the



keys then press 

 to confirm.

MUX CONVERSION

SINGLE MUX FILTERING

TWO MUX FILTERING

The L figure shows the input level of the selected MUX in 

dBµV.

DELETE FILTER

> 5-> 5 L 65

 PREAMP:  ON

> 5-> 8 L 65

 PREAMP:  ON

Output conversions up to the UHF channel 69 

are permitted.

DAB FILTER

 PREAMP: ON

 > VHF-DAB

To activate the single 65MHz DAB filter press 

until   

the figure 

VHF-DAB 

is shawn, then press 

⏎ 

to confirm.

FILTERS OVERLAPPING

>10<> 8*L 70

  8<> 8*L 65

The selection of two or more output filters with the 

same frequency is allowed but marked with 

*

Содержание DSP30-4G

Страница 1: ...HF INPUTS FREQUENCY RANGE MHz FM 40 108 BIII 170 230 DAB 170 240 UHF 470 790 LTE PROTECTION LTE790 SINGLE CHANNEL FILTERS 32 NUMBER OF CHANNEL PER FILTERS 1 2 INPUT LEVEL RANGE dB V FM 35 90 BIII DAB...

Страница 2: ......

Страница 3: ...ng processes CAUTION To avoid the risk of electric shock do not open the equipment LEM GUI AUTO TUNING High rejection SAW filters for optimal protection against Lte 4G interferences In addition to the...

Страница 4: ...P55 rating and fix it safely using the provided fixing plugs 4 Connect the power adapter cord to a detachable power supply socket Safety instructions IMPORTANT Use only the power supplier YS25 1501250...

Страница 5: ...nputs 3 Connect the MATV output and terminate the unused inputs with 75 loads 4 Connect the power supplier unit to the DSP30 4G and then connect the power supplier to mains plug Installation and start...

Страница 6: ...75 loads 4 Connect the power supplier unit to the coaxial DC injector INS02 and then connect the power supplier to mains plug DC Coaxial Injector not included Installation and start up UHF BIII DAB UH...

Страница 7: ...g menu OUTPUT LEV 110dBuV Confirmation Key Menu browsing keys Display LDC 2 x 12 Pointer to scroll figures Function Selector Note the display will go out after 3 minutes if inactive but the menu will...

Страница 8: ...ING procedure press for 5 seconds To begin the AUTO TUNING procedure connect the antenna s to the DSP30 4G inputs then follow the operations described below The amplifier DSP30 4G will start scanning...

Страница 9: ...T FM BI ATTENUATOR Adjustable 0 12 24dB ATTN 12dB INPUT FM BI INPUT VHF 1 To set the INPUT VHF 1 parameters press to enter the menu INPUT 1 VHF INPUT 1 VHF Processable channels Input E5 E13 DAB Output...

Страница 10: ...s and then press twice to confirm 5 5 L 65 PREAMP ON To activate the filtering and conversion function on a single MUX set the desired input channel through the keys and press to confirm Select the ou...

Страница 11: ...PUT 3 UHF OUTPUT LEVEL SELECTION Adjustable from86to106dB V LEV 105dBuV SLP 5dB To adjust the UHF slope select SLP and press press to select the required value and press to confirm UHF SLOPE Adjustabl...

Страница 12: ...t THR the AUTO TUNING and MONITOR miminum threshold function and press Use the keys to select the required value and press to confirm REMOTE POWER SUPPLY PROTECTION PASSCODE AUTO TUNING INPUTS THRESHO...

Страница 13: ...mming mode and press to confirm To carry on with the programming select NO and press to confirm THR 55dBuV RESET MONITOR RESET MONIT OFF The MONITOR function activates a real time monitoring procedure...

Страница 14: ...lease check the power supplier DC NOT VALID Display Error Messages OVERCURRENT Input short circuit or over current Please check the input s with the remote power supply activated and remove the issue...

Страница 15: ...0 4G Label with serial and tracking data Model Serial Manuf Week Manuf Year HW Rel FW Rel 1 Download the latest GUI release from our website http www lemelettronica it 2 Install the GUI selecting the...

Страница 16: ...LEM ELETTRONICA srl Via Grezze 38 25015 Desenzano d G Italy Tel 39 0309120006 Fax 39 0309123035 info lemelettronica it www lemelettronica it...

Отзывы: