7
Select user language / record individual message
Details according to section 6.3
12. Slide
function switch
to PROG
13. Enter
*
.
*
.
#
.
Current individual message will be announced followed by “to modify press * , to stop press # “
14. Select language for user announcements: (facultative)
Press key
1
to
4
to select user languages: 1 for German, 2 for French, 3 for English GB, 4 for Italian
15. Press
*
and start speaking
16. Press
#
to finish recording, max. duration is 12 seconds
New individual message will be announced. You can repeat steps 14 to 16 until text is fine!
17. Slide
function switch
to OFF
Program PIN-code
Details according to section 6.4
18. Slide
function switch
to PROG
19. Press key
#
.
You can prevent the alarm unit from unintended re-programming by pressing
*
..
20. Enter PIN-code (4 to 7 digits)
21. Press key
#
.
22. Re-enter PIN-code for confirmation
23. Press key
#
.
New PIN-code will be announced
24. Slide
function switch
to OFF
Alarm unit is now ready for operation
Details according to section 7
25. Slide selection switch to the requested position (I/II/III)
4.1.4 Activation of motion sensor
Provided the motion detector is plugged in,
detects the motion detector during the switching on procedure.
Important notes:
By disconnecting the motion detector during the operation mode, an alarm is
triggered followed by the announcement: ”alarm due to sensor 1, sensor failure!”
By connecting the motion detector after the start up procedure of the alarm unit,
an alarm is triggered followed by the announcement: “alarm due to sensor 1,
sensor 1 activated!”
4.1.5 Deactivation of motion sensor
If the motion detector is not plugged in,
automatically deactivates the
supervision of the motion detector.
4.1.6 Adjustment
Safety note:
Before you open cover please check, that the telephone cord is DISONNECTED.
Otherwise you can get in contact with the telecommunication voltage!
Remove the front cover by twisting a flat screwdriver in the slot between the cover and
the base at the bottom of the motion detector
4.1.6.1
Pulse count
You can set PULSE jumper at position 1,2 or 3 corresponding to the desired pulse count
before an alarm will be triggered. Default = 2.
4.1.6.2
WALK-test
To disable LED indication, remove the LED jumper and place it on one pin only. To
activate LED indication, place LED jumper over both pins.
4.1.6.2.1
Mounting height
If motion detector is not mounted at 2.5m you can adjust like this:
1.
Loosen the PC-Board holding screw. Slide the PC-Board so that the plastic pointer
on the right side is positioned at the appropriate scale position.
For higher than 2.5m => Slide PC-Board up
For lower than 2.5m => Slide PC-Board down
2.
Tighten the PC-Board holding screw
3.
Mount front cover
4.
Walk through the entire protected area and observe the LED to ensure full coverage
Mounting screw