Page 10
For HELP, call 727.573.9611
Our hot tubs are certified by Intertek Testing, SNAa Ltd.
Ontario, Canada to CSA-C22.2 No. 218.1-M89 and ANSI/UL
1563 standards.
Parts with extra low voltage not exceeding 12v must be inaccessible to a person
in the hot tub. Earthed appliances must be permanently connected to fixed
wiring. Parts incorporating electrical components, except remote control devices,
must be located or fixed so that they cannot fall into the hot tub.
Means for disconnection must be used in fixed wiring in accordance with wiring
rules.
Important –
To allow the 240V GFCI to function properly, connect the white
Neutral wire from the hot tub to the Neutral terminal on the GFCI breaker, not the
Neutral bus in the GFCI breaker box. An improperly connected Neutral causes
the GFCI breaker to trip.
Wiring Diagrams
GFCI
G
N
D
N
E
U
T
Correct
To
Spa
To
Main
Hot Tub GFCI Breaker Box Wiring
Incorrect
2 White wires
on Neutral Bus
3 White wires
on Neutral Bus
GFCI
G
N
D
N
E
U
T
To
Main
To
Spa
Figure 3 – 240V GFCI Wiring
The following diagrams and information show how to properly wire your new
Leisure’s Edge hot tub.
Содержание LE 744
Страница 9: ......
Страница 13: ......
Страница 18: ...Page 16 For HELP call 727 573 9611...
Страница 19: ...Page 17 For HELP call 727 573 9611 U S and Canada Wiring LE 630...
Страница 20: ...Page 18 For HELP call 727 573 9611 Figure 11 Board Diagram for LE 630 Model Single phase 240V Domestic version...
Страница 29: ...Page 27 For HELP call 727 573 9611...
Страница 43: ...Page 41 For HELP call 727 573 9611...
Страница 45: ......
Страница 57: ...Page 55 For HELP call 727 573 9611 LE 744 Callouts LE 744 Parts Domestic...
Страница 59: ...6101 45th St N St Petersburg FL 33714 727 573 9611 www PremiumLeisure com...