24
6.2 Operating conditions
• Check the
welding nozzle (3)
basic setting.
• Connect the tool to the line supply. The line voltage must correspond with the voltage rating stated on the tool.
6.3 Switching on
Set the
air blower switch (9)
to I. Press the
SELECT button (12)
once.
The heating process starts with the last-saved settings. Select the desired program or program the temperature
and air flow as required.
Language selection Temperature
°C / °F (see 6.4)
or
Selecting the function program
(see 6.4).
Start by pressing the
SELECT Menu button (12).
Note: When an indication flashes on the
display (11),
a change
can be initiated by pressing either the
PLUS (13)
or
MINUS (15) button.
Press the
SELECT button (12)
again to
go to the next step.
6.4 Adjusting the settings on the terminal (10)
Language selection, temperature unit °C / °F
Selecting the function program
1. Welding
PVC
2. 1-Free
setting
3. 2-Free
setting
The name of the program corresponding to the selected function program flashes on the display. Longer text scrolls
across the screen after 2 seconds and the name of the program is displayed again after 2 cycles. Within this period,
the
SELECT Menu button (12)
can be pressed again to adjust the temperature or the air flow.
1 ×
1 ×
1 ×
1 ×
1 ×
1 ×
1 ×
2 sec