TECHNICAL DATA
DANGER!
Danger when opening up the tool, as live components and
connections are exposed. Therefore, before opening it,
unplug the tool to ensure disconnection from the mains.
Electronically conductive material (eg PE-EL) must not be
welded.
Incorrect use of the hand extruder (eg overheating of the
material) can present a
fire and explosion hazard
, espe-
cially near combustible materials and explosive gases.
The tool must be operated
with supervision
. Heat can
reach combustible materials, which are out of sight.
For personal protection on building sites we
strongly recom-
mend
the tool be connected to a
RCCB
(
R
esidual
C
urrent
C
ircuit
B
reaker) .
The
voltage rating
stated on the tool must correspond to
the mains voltage.
Do not touch the element housing, air nozzle and
discharging plastizised material when they are hot as
they can cause
burns
. Let the tool cool down. Do not
point the hot air flow and the discharging plastizised
material in the direction of people or animals.
Protect tool from
damp
and
wet
.
FI
120
230
WARNING
CAUTION
Voltage
V~
120
200
230
Power consumption
W
1800
2200
2200
Frequency
Hz
50/60
Air Temperature
°C max.
400
Air flow
l/min
300
Plast. Temperature
°C max.
270
Welding output
kg/h
0.7
Welding rod
mm
ø 4 ± 0.2 (in accordance with DVS 2211)
Size L
××
W
××
H
mm
443
××
94
××
255, handle
ø
57
Weight
kg
3.8 (without cable to mains)
Electrical Safety: double insulated
APPROVAL MARK
This tool is
CCA
certified (
C
ENELEC
C
ertification
A
greement).
Line/mains
voltage cannot
be switched over