OPERATING

Leister LHS CLASSIC

3

Installation

• When installing the tool, ensure that:

- only cold air is supplied
- no (hot air) back pressure develops
- the tool is not subjected to a hot air flow from another tool

• The tool is protected against mechanical vibration and shaking.
• Installation dimensions on pages 5, 6 and 7.

Air supply

• To protect the tool and the heat element, the stipulated minimum air flow must

under no circumstances fall short, and the maximum temperature (measured
at the hotest point 3 mm in front of the element housing) must also not be
exceeded. In the event that the minimum air flow falls short, the power must
immediately be disconnected.

• The air heater should only be supplied with air up to a max. 80°C.
• Pay attention to the direction of the airflow.
• Leister blowers must be used for the air supply (pay attention to the direction of

rotation and the electrical connection).

• For use in a dusty environment the tool should be fitted with a Leister stainless

steel filter on the air intake connection. Where a particularly critical dust problem
exists (eg metal, electrically charged or damp dust) special filters must be used to
avoid short circuiting of the tool.

Operation

• The tool must be connected by a qualified electrician in accordance with the

circuit diagram (Pages 5,6 or 7).

• Fit a nozzle appropriate to the use.
• It should be checked that the hot air can flow out freely, otherwise a back

pressure of hot air may damage the tool (danger of fire!).

• Attention: Keep to the minimum air flow according to the technical details

(Page 2).

• Switch on mains.
• Allow the tool to cool down after use.

Attention: Never operate tool without air supply!

Содержание LHS CLASSIC 20S

Страница 1: ...ning solvent free adhesives and melt adhesives Sterilizing packaging materials such as bottles corks and containers Separating and fusing synthethic fibres and fabrics Soldering processes on thin meta...

Страница 2: ...tool live components and connections are exposed The mains plug must be removed from the main socket before opening up the tool Caution separate source voltage Incorrect installation and use of air he...

Страница 3: ...attention to the direction of the airflow Leister blowers must be used for the air supply pay attention to the direction of rotation and the electrical connection For use in a dusty environment the t...

Страница 4: ...rating contact of the alarm relay will open Measures to be taken if the heating element or tool protection cuts out Remove electronic control from the mains After 10 seconds the electronics reset auto...

Страница 5: ...5 CONNECTION INSTALLATION Leister LHS CLASSIC 20 Installation dimensions in mm F2 Fuse P N F1 Max 10A L N COM NO 230V 0V 24V N L1 Insulation K1 K1 Circuit Diagram 20S...

Страница 6: ...eister LHS CLASSIC 40 6 Installation dimensions in mm COM NO 230V 0V 24V F2 Fuse P N F1 Max 10A L1 N Insulation K1 K1 L3 L2 L1 L2 L3 N L1 COM NO 230V 0V 24V F2 Fuse P N F1 Max 10A L N Insulation K1 K1...

Страница 7: ...CONNECTION INSTALLATION Leister LHS CLASSIC 60 7 Installation dimensions in mm L3 L2 L1 COM NO 230V 0V 24V D0 D1 F2 Fuse P N F1 Max 10A L1 N K1 K1 L2 L3 Insulation PE Circuit Diagram 60S 60L...

Страница 8: ...sing original spare parts in accordance with the circuit diagrams and spare parts lists For this tool we generally provide a warranty of one 1 year from the date of purchase verified by invoice or del...

Отзывы: