Technical Data

LHS 

LHS

LHS

LHS

LHS

CLASSIC 20S CLASSIC 40S CLASSIC 40L CLASSIC 60S CLASSIC 60L

Voltage

V~

100 - 230

100 - 230

3

×

230-3

×

440 3

×

230-3

×

480 3

×

230-3

×

480

Frequency

Hz

50/60

50/60

50/60

50/60

50/60

Power consumptionkW

1.0 / 2.0

2.0 / 4.0

2.0 / 4.0

4.0 / 6.0

8.0 - 16.0

Min. air flow

l/min.

200 300

300

400

600

Max. temperature°C

600

600

600

600

600

Ambient

°C

<

65

<

65

<

65

<

65

<

65

temperature

Weight

kg

0.55

0.85

0.95

3.15

3.65

Size

mm

252

×

97

×

87

261

×

112

×

98 291

×

112

×

98 379

×

116

×

137 379

×

116

×

137

Mark of conformity

2

2

2

2

2

Mark of Approval

3

3

3

3

3

Certification scheme

CCA

CCA

CCA

CCA

CCA

Protection class I

1

1

Protection class II

4

4

4

2

Danger! 

When opening up the tool, live components and

connections are exposed. The mains plug must be removed
from the main socket before opening up the tool. 

Caution

separate source voltage.

Incorrect installation and use of air heaters can present
a

fire and explosion hazard

, particularly in the proximity of

flammable materials and explosive gases.

Do not touch the element housing and nozzle when hot
as they can cause

burns. 

Do not point the hot air flow at

people or animals.

WARNING

The tool must be operated 

with supervision

. Warmth can

reach combustible materials, which are out of sight.

The

voltage rating 

stated on the tool should correspond

to the mains voltage.
IEC/EN 61000-3-11; Z

max

0.047

Ω 

+ j 0.029

. If necessary,

consultate supply authority.

Protect the tool from 

dampness

and 

wet

.

CAUTION

The tool with protection class I should be earthed using a
protective conductor.

100

480

Содержание LHS CLASSIC 20S

Страница 1: ...ning solvent free adhesives and melt adhesives Sterilizing packaging materials such as bottles corks and containers Separating and fusing synthethic fibres and fabrics Soldering processes on thin meta...

Страница 2: ...tool live components and connections are exposed The mains plug must be removed from the main socket before opening up the tool Caution separate source voltage Incorrect installation and use of air he...

Страница 3: ...attention to the direction of the airflow Leister blowers must be used for the air supply pay attention to the direction of rotation and the electrical connection For use in a dusty environment the t...

Страница 4: ...rating contact of the alarm relay will open Measures to be taken if the heating element or tool protection cuts out Remove electronic control from the mains After 10 seconds the electronics reset auto...

Страница 5: ...5 CONNECTION INSTALLATION Leister LHS CLASSIC 20 Installation dimensions in mm F2 Fuse P N F1 Max 10A L N COM NO 230V 0V 24V N L1 Insulation K1 K1 Circuit Diagram 20S...

Страница 6: ...eister LHS CLASSIC 40 6 Installation dimensions in mm COM NO 230V 0V 24V F2 Fuse P N F1 Max 10A L1 N Insulation K1 K1 L3 L2 L1 L2 L3 N L1 COM NO 230V 0V 24V F2 Fuse P N F1 Max 10A L N Insulation K1 K1...

Страница 7: ...CONNECTION INSTALLATION Leister LHS CLASSIC 60 7 Installation dimensions in mm L3 L2 L1 COM NO 230V 0V 24V D0 D1 F2 Fuse P N F1 Max 10A L1 N K1 K1 L2 L3 Insulation PE Circuit Diagram 60S 60L...

Страница 8: ...sing original spare parts in accordance with the circuit diagrams and spare parts lists For this tool we generally provide a warranty of one 1 year from the date of purchase verified by invoice or del...

Отзывы: