12
Device description
Installation
• The device may only be installed by trained personnel.
• The installation must ensure that
– no excess (heat) residue builds up.
– the device is not subject to jets of hot air from another device.
• Protect the device from mechanical vibrations and shocks.
• For installation dimensions, see pages 3, 4 (Size).
Air supply
• As air supply, suitable blowers have to be used (pay attention to the direction of rotation).
• In order to protect the heating element, the specified minimum air volume must never be fallen below and the ma-
ximum temperature (hottest point measured 3 mm in front of the heating element tube) must never be exceeded
(see technical data). If the minimum air volume is fallen below, the heat output must be interrupted immediately.
• Air Heater type DF-R may only be supplied with air up to max. 350 ° C / 662 ° F.
• Observe direction of air flow.
• For use in a dusty environment the tool should be fitted with a Leister stainless steel filter on the air intake
connection. Where a particularly critical dust problem exists (e.g. metal, electrically charged or damp dust)
special filters must be used to avoid short circuiting the tool.
Attention: always operate device with air supply !
Connection
• The air heater must be connected by qualified personnel.
• A suitable device for full disconnection from the mains must be provided in the mains connection!
• It must be ensured that the connection lines do not come into contact with the heating element tube and are not
exposed to the hot air jet.
•
Only the installed temperature-resistant special cord may be used for the electrical connection.
• The power supply cord may only be replaced by a qualified expert or a Leister service centre.
• It must be ensured that the power supply cord is protected against mechanical strain when routing it.
• The device must be connected in accordance with the connection on page 5 (Wiring Diagram) of the operating
instructions.
• Connect air heater to the electrical mains.
• It must be ensured that the hot air can flow out freely, as otherwise the device can be damaged by the excess
heat building up (risk of fire!).
• Attention: comply with minimum air volume and maximum air temperature as per technical data.
• Switch on mains.
• Allow device to cool down after heating mode.
Air intlet
Cable gland
Nameplate
Heating element tube
with air outlet
Содержание LE 10000 DF-R
Страница 3: ...3 LE 5000 DF R Size mm 20 184 5 1 92 5 102 116 M 6 88 80 7 6 6 0...
Страница 5: ...5 Wiring Diagram LE 5000 DF R LE 10000 DF R K1 PE L1 Power L1 F2 L2 L3 L2 L3...
Страница 34: ...34 CN 100 480 LE 5000 DF R LE 10000 DF R I LE 5000 DF R LE 10000 DF R...
Страница 36: ...36 mm 3 4 3 mm DF R 350 C 662 F 5...
Страница 37: ...37 3D 3D www leister com FC 550 117 359 DSE www leister com...
Страница 38: ...38 Pb Hg Cd Cr VI PBB PBDE PCB SJ T 11364 GB T 26572 GB T 26572...
Страница 39: ...39 J 100 480 LE 5000 DF R LE 10000 DF R LE 5000 DF R LE 10000 DF R...
Страница 41: ...41 mm 3 4 3 mm DF R 350 662 F Leister 5...
Страница 42: ...42 Leister Technologies AG 3D www leister com 3D Leister FC 550 117 359 DSE www leister com...