69
Troubleshooting
9
Troubleshooting
Display
Symptom
Possible Causes and Solutions
Roll Icon
The Roll Icon indicates that the Piper is in a position where its
cross-axis level vial is not level. Reposition the Piper in the direc-
tion of the arrow until the vial is centered.
Servo Limit
The Servo Limit Icon indicates that the Piper is in a position where
it cannot achieve the entered grade. Reposition the Piper in the
direction of the arrow until the unit can once again level itself.
Temperature Limit
The Temperature Limit Icon indicates that the Piper is in an envi-
ronment where it cannot operate without causing damage to the
laser. This could most often be the result of direct sunlight. Shade
the unit.
Empty Battery
The Empty Battery Icon indicates that the Piper’s battery requires
a recharge. Remove and replace or recharge the battery. The Piper
uses an intelligent battery system that indicates the remaining
battery charge. This is displayed at power up and at all other times
on the main operating screen.
Sleeping Piper
The Sleeping Piper Icon indicates that the Piper has been placed in
standby mode with the Remote. Press any button to reactivate the
Piper.