26
Technical Data
LEICA GEOVID 8 x 42 BRF
LEICA GEOVID 10 x 42 BRF
Magnification
8 x
10 x
Lens diameter
42 mm
Exit pupil
5.25 mm
4.2 mm
Twilight number
18.33
20.5
Geometric luminous intensity
27.56
17.64
Field of view
(at 1000m/yds)
125 m/yds / 7.1°
110 m/yds / 6.3° (wide angle)
Close range limit
(at 0 dioptres)
approx. 5.6 m/18’4’’
approx. 5.6 m/18’4’’
Exit pupil longitudinal distance
18.5 mm
15.6 mm
Pupil distance
56–74 mm
Prism type
Roof
Coating
on lenses
High Durable Coating (HDC™)
on prisms
Phase correction coating P40
Dioptre compensation
approx. ± 3.5 dioptres
Suitable for wearers of glasses
yes
Operating temperature
–25°C/–13°F to +55°C/+131°F
Storage temperature
–40°C/–40°F to +85°C/+185°F
Water tightness
0.5 bar (approx. 5 m water depth)
Housing material
die cast aluminium
Maximum range
approx. 1200 m/1300 yds
Minimum distance
10 m/yds
Metering accuracy
±1 m/yd up to 350 m/380 yds
±2 m/yds up to 700 m/763 yds
±0.5 % above 700 m/763 yds
Display/
4-digit LED
Measuring unit
available either in Meter- or Yard-version
Battery
1 lithium cell 3 V Type CR 2
Battery life
1
≥ 1000 measurements
Laser
safe for eyes to EN and FDA Class 1
Laser beam divergence
2.5 x 0.5 mrad
Maximum metering duration
approx. 1.4 s
Dimensions
(W
2
x H
3
x D
2
)
approx. 124 x174 x 65 mm
Weight
(including battery)
approx. 945 g
1
At 20°C and average usage profile
2
With eye spacing 65 mm
3
With eyepiece cups screwed in