Troubleshooting
Fault
Cause
Remedy
Circular field is not achieved
a) The binoculars are not
a) Simply correct the
during viewing
correctly adjusted to
eyebase of the two
personal eye base.
binocular tubes by
bending the hinged axis
inwards or outwards.
b) The viewer's pupil is not in
b) Correct head, eye and
the binoculars' exit pupil.
binocular position.
c) The position of the
c) Correct adjustment:
eyepiece cups does
If wearing glasses, screw
not match the correct
in eyepiece cups; for
use with and without
viewing without glasses:
glasses.
unscrew eyepiece cups.
Image out of focus
Dioptre compensation
Repeat dioptre
is not accurate
compensation (see p. 21)
During distance metering, the
a) Object too close or
Note information on
display shows "- - -"
metering range
metering range (see p. 23)
exceeded
b) The object is
insufficiently reflective
Display is flashing or metering
Battery flat
Replace battery (see p. 18)
not possible