218
Technical Data
)
The range on the round prism is only achievable with the upgraded distance meas-
urement. Otherwise the specifications of the CPR111 are valid (max. 1000 m). Please
refer to "5.4 Distance Measurement".
Atmospheric condi-
tions
Accuracy
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
1:
Strong haze, visibility 5km; or strong sunlight, severe heat shimmer
2:
Light haze, visibility about 20km; or moderate sunlight, slight heat shimmer
3:
Overcast, no haze, visibility about 40km; no heat shimmer
Standard measuring
Standard deviation,
ISO 17123-4
Measure time, typical [s]
Fine
2 mm + 2 ppm
< 1
Fast
5 mm + 2 ppm
< 0.5
Tracking
5 mm + 2ppm
< 0.3