Introduction

Congratulations on the purchase of the Leica BLK ARC.

This manual contains important safety directions as well as instructions for

setting up the product and operating it. Refer to 

1 Safety Directions

 for fur-

ther information.
Read carefully through the User Manual before you turn on the product.
The content of this document is subject to change without prior notice. Ensure

that the product is used in accordance with the latest version of this docu-

ment.

The model and serial number of your product are indicated on the type plate.
Always refer to this information when you need to contact your agency or

Leica Geosystems authorized service center.

Trademarks are the property of their respective owners.

On the last page of this manual, you can find the address of Leica Geosystems

headquarters. For a list of regional contacts, please visit

http://leica-geosystems.com/contact-us/sales_support

.

Name

Description/Format

Leica

BLK ARC

Quick Guide

Provides an overview of the instrument together

with technical data and safety directions. Intended

as a quick reference guide

ü

ü

Leica

BLK ARC

User Manual

Provides all required instructions to operate the

instrument to a basic level. Provides an overview

of the instrument together with technical data and

safety directions.

-

ü

Leica

BLK ARC

Tutorial

videos

Tutorial videos explaining the basic workflow and

including assembly instructions.

-

-

QR Code

Scan the following QR code to watch the BLK ARC instruction video.

 

Purchase

Product identification

Trademarks

Leica Geosystems

address book

Available

documentation

2

Содержание BLK ARC

Страница 1: ...Leica BLK ARC User Manual Version 1 0 English US ...

Страница 2: ...operty of their respective owners On the last page of this manual you can find the address of Leica Geosystems headquarters For a list of regional contacts please visit http leica geosystems com contact us sales_support Name Description Format Leica BLK ARC Quick Guide Provides an overview of the instrument together with technical data and safety directions Intended as a quick reference guide ü ü ...

Страница 3: ...Refer to the following resources for all BLK ARC documentation soft ware the Leica USB documentation card https myworld leica geosystems com 3 ...

Страница 4: ...tting Started 22 5 2 Imaging 22 5 3 Scanning 23 5 3 1 Ambient Conditions 23 5 3 2 Troubleshooting 23 5 3 3 Field of View FoV 24 5 4 Data Transfer 24 5 5 Cooling System 25 6 Care and Transport 26 6 1 Maintenance 26 6 2 Transport 26 6 3 Storage 26 6 4 Cleaning and Drying 26 6 5 Dome Cleaning Procedure 27 6 6 Filter Changing Procedure 28 7 Technical Data 31 7 1 General Technical Data of the Product 3...

Страница 5: ...fying levels of hazards and risks related to personal injury and property damage For your safety it is important to read and fully understand the following table with the different signal words and their definitions Supple mentary safety information symbols may be placed within a warning message as well as supplementary text Type Description DANGER Indicates an imminently hazardous situation which...

Страница 6: ...he prior explicit approval of Leica Geosystems Inadequate safeguards at the working site WARNING Unauthorized modification of automatic machines and robots by mounting or installing the product This may alter the function and safety of the machine Precautions Follow the instructions of the machine robot manufacturer If no appropriate instruction is available ask machine robot manufacturer for inst...

Страница 7: ...spected WARNING Unqualified installation on automatic machines and robots This may result in personal and material damage Precautions This product may be installed on automatic machines and robots only by an appropriately trained and qualified specialist 1 5 Hazards of Use WARNING Distraction or loss of attention During dynamic applications there is a danger of accidents occurring if the user does...

Страница 8: ...down of the system This could lead to a loss of essential system information Precautions Always ensure proper shutdown of the system Do not force shutdown of the system CAUTION Before any cleaning procedure ensure that the instrument is switched off CAUTION Unused connectors must be protected using the attached dust cap CAUTION Improperly secured accessories If the accessories used with the produc...

Страница 9: ...t or fragments creating a health hazard Precautions The product must not be disposed of with house hold waste Dispose of the product appropriately in accordance with the national regulations in force in your coun try Always prevent access to the product by unauthor ized personnel Product specific treatment and waste management information can be received from your Leica Geosystems distributor WARN...

Страница 10: ...jects CAUTION No original or authorized accessories The correct functioning of the system is not guaranteed Precautions Use only original and authorized accessories for the BLK ARC system CAUTION Disregard the temperature specifications The correct functioning of the system is not guaranteed Precautions Do not use the system during rain snowfall fog or extensive sunshine Be careful to attend to th...

Страница 11: ... an electric shock Precautions If the product becomes humid it must not be used Use the product only in dry environments for example in buildings or vehicles Protect the product against humidity 1 6 Laser Classification 1 6 1 General The following chapters provide instructions and training information about laser safety according to international standard IEC 60825 1 2014 05 and technical report I...

Страница 12: ... is classified as laser class 1 in accordance with IEC 60825 1 2014 05 Safety of laser products These products are safe under reasonably foreseeable conditions of operation and are not harmful to the eyes provided that the products are used and maintained in accordance with this User Manual Description Value Wavelength 830 nm Maximum pulse energy 9 nJ Pulse duration 3 ns Pulse repetition frequency...

Страница 13: ...is device complies wi t h p a r t 1 5 o f t h e F C C R u l e s 0 0 360 90 b a 270 23090_001 a Location of laser beam b Sphere of scanning laser beam 1 7 Electromagnetic Compatibility EMC The term Electromagnetic Compatibility is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present and without ca...

Страница 14: ...ransponders two way radios or diesel generators Although the product meets the strict regulations and standards which are in force in this respect Leica Geosystems cannot completely exclude the possib ility that the function of the product may be disturbed in such an electromag netic environment Precautions Check the plausibility of results obtained under these conditions CAUTION Electromagnetic r...

Страница 15: ...exclude the possibility that other equipment can be disturbed or that humans or animals can be affected Do not operate the product with radio or digital cellular phone devices in the vicinity of fuel stations or chemical installations or in other areas where an explosion hazard exists Do not operate the product with radio or digital cellular phone devices near medical equipment Do not operate the ...

Страница 16: ...01 e d c a b a BLK ARC Laser scanner b GEV290 USB C extension cable for BLK ARC c GEV291 Power extension cable for BLK ARC d GEV278 USB C cable 50 cm e GEV276 Power supply unit with DC power cord country specific System components 16 Description of the System ...

Страница 17: ... ARC Laser scanner c GEV276 Power supply unit and DC power cords US EU UK AUS or CH d GEV278 USB C data cable e BLK ARC Quick Guide f Leica USB documentation card g BLK Cleaning cloth h GEV291 Power extension cable for BLK ARC i GEV290 USB C extension cable for BLK ARC Container contents Description of the System 17 ...

Страница 18: ...0_001 g h h h f e a b c d d i j a Dome b Ring shaped LED c Detail camera d Panoramic camera e Air inlet 2x f Air outlet g USB plug h Mounting location i Power plug j Cable fixations Instrument components 18 Description of the System ...

Страница 19: ...ls to show the operation states of the BLK ARC 23151_001 Description Details Colors Green Yellow Red Lighting intervals Continuous Blinking Pulsating 1 blink LED color Lighting interval Instrument status none The BLK ARC is off continuous The BLK ARC is ready Instrument status Operation mode User Interface 19 ...

Страница 20: ...a problem occurred 1 blink An error occurred and the picture from the detail camera was not taken continuous Critical problem or major fail ure Contact a Leica Geosystems authorized service center for fur ther investigation LED color Lighting interval Instrument status blinking The BLK ARC is running a firmware update continuous The firmware update was success ful The BLK ARC is in idle state cont...

Страница 21: ...t voltage 100 240 V AC NOTICE Electromagnetic immunity The product may be disturbed by other equipment during operation with the power supply Precautions Operate the product with the AC DC power supply only in a domestic environment Power supply Power Supply 21 ...

Страница 22: ...shaped LED starts pulsating green the BLK ARC is initialized and is recording data The carrier can start moving and the BLK ARC is collecting the data 6 Stop the scan from the connected device The ring shaped LED is blinking yellow while data are being saved Once data have been saved the ring shaped LED is continuous green 5 2 Imaging The BLK ARC can collect two different types of images A panoram...

Страница 23: ... the instrument is brought from a cold environment for example from stor age into a warm and humid environment the mirror or in extreme cases even the interior optics can condense This may cause measurement errors Precaution Avoid rapid temperature changes and give the instrument time to acclimatize Due to the encapsulated mirror design the mirror is protected against direct contact But dirt on th...

Страница 24: ...ww blkarc com for support information and contacts 5 3 3 Field of View FoV 23154_001 0 0 360 270 90 270 a b a Vertical field of view 270 b Horizontal field of view 360 5 4 Data Transfer Raw data can be transferred from the BLK ARC to a computing device using a USB cable data transfer or a wireless connection Connect 23155_001 Troubleshooting in operation mode Troubleshooting support contacts Scann...

Страница 25: ...place the filter cartridge by a new filter periodically To remove the filter refer to Filter Changing Procedure and follow the instruc tions The exchanging period depends on the environment where the BLK ARC is mostly used The more dusty the environment is the more frequently the filter has to be exchanged The BLK ARC is not supposed to work in a dusty environment since the laser measurements suff...

Страница 26: ...o container is available use the original packaging or its equivalent When transporting the product by rail air or sea always use the complete original Leica Geosystems packaging container and cardboard box or its equi valent to protect against shock and vibration 6 3 Storage Respect the temperature limits when storing the equipment particularly in summer if the equipment is inside a vehicle Refer...

Страница 27: ...eaning procedure the wet and dry lens cleaner Green Clean LC 7010 is recommended www green clean at en html Clean the glass pane regularly with the recommended cleaning tissue It is recommended to leave the BLK ARC on a carrier mounted for stability Avoid handling the BLK ARC in your hands Turn off the BLK ARC if you are holding the instrument in your hands If the BLK ARC is mounted on the carrier...

Страница 28: ...ration in standard working conditions it can be necessary to exchange the filters NOTICE Running the device without filters If the device is used without filters dust is drawn inside and irretrievably damages inner components Precautions Do not run the device without the filters Ensure that both filters are inserted correctly CAUTION Before any cleaning procedure ensure that the instrument is swit...

Страница 29: ...e used filter The filter cannot be removed from the filter cover as it is one part and has to be exchanged together 3 Insert a new filter cover with filter in both air inlets Ensure that both filter covers are inserted correctly 4 Fasten the screw Position of air inlet and air outlet Changing the filter of the air inlet step by step Care and Transport 29 ...

Страница 30: ...672_001 Cleaning the air outlet can be done only from the outside Do not use compressed air to clean the air outlet If some particles of dust are clearly stuck inside the mesh do not try to remove the particles It may force the particles to move further in and damage the mesh Cleaning the air out let 30 Care and Transport ...

Страница 31: ...omatic Minimum range 30 cm Shutter Global 7 2 System Performance All accuracy specifications are one sigma 1σ under Leica Geosystems standard test conditions unless otherwise noted Accuracy of single measurement at 78 albedo Value Angle horizontal vertical 30 30 3D point accuracy 3 mm 10 m 7 3 Laser System Performance The scanning system is a high speed time of flight unit enhanced by Wave form Di...

Страница 32: ...level 20 µm Protection against splashing water from any direction AC DC power supply IPX0 IEC 60529 Only operate in dry environments for example in buildings and vehicles Type Humidity Instrument max 95 non condensing AC DC power supply max 80 non condensing Type Limits of use Instrument Indoor and outdoor use Working altitude unlimited AC DC power supply Indoor use only Working altitude 2000 m Ty...

Страница 33: ... 0 690 1 52 7 8 Accessories Included standard accessories BLK ARC box BLK ARC Laser scanner GEV290 USB C extension cable for BLK ARC GEV291 Power extension cable for BLK ARC GEV278 USB C data cable GEV276 Power supply unit and DC power cord country specific BLK ARC Quick Guide Leica USB documentation card BLK Cleaning cloth Dimensions Weight Scope of delivery Technical Data 33 ...

Страница 34: ...ation is subject to t h e f o l l o w i n g t w o This device complies wi t h p a r t 1 5 o f t h e F C C R u l e s 23091_001 Type Frequency band MHz WLAN 2412 2462 Client mode 5180 5240 5260 5320 5500 5700 Type Output power mW WLAN 100 max Type Antenna Gain dBi WLAN Dual dipole antenna MIMO system 3 Hereby Leica Geosystems AG declares that the radio equipment type BLK ARC is in compliance with Di...

Страница 35: ...ce could void the user s authority to operate the equipment This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada Canada Compliance Statement This device contains license exempt transmitter s receiver s that com ply with Innovation Science and Economic Development Canada s license exempt RSS s Operation is sub...

Страница 36: ...ms and conditions of the Leica Geosystems Software License Agree ment Installation or use of the software or any part thereof is deemed to be an acceptance of all the terms and conditions of such License Agreement If you do not agree to all or some of the terms of such License Agreement you must not download install or use the software and you must return the unused software together with its acco...

Страница 37: ......

Страница 38: ...Leica Geosystems AG Heinrich Wild Strasse 9435 Heerbrugg Switzerland www leica geosystems com 954934 1 0 0en us Original text 954932 1 0 0en Published in Switzerland 2021 Leica Geosystems AG ...

Отзывы: