Rugby 610, Applications
26
5.3
Manual Grades
Manual Grading
step-by-step
Application shown using the Rod Eye 140, Classic Receiver.
Step
Description
1.
Set up the Rugby and the slope adapter on a tripod.
2.
Set up the tripod at the base of the slope with the Rugby and the slope
adaptor pointing in the direction of the desired slope.
3.
Set the slope adapter to the zero position on the bracket and on the knob.
4.
Roughly level the top of the tripod using the circular level on the slope
adapter.
5.
Before entering grade in the slope adapter, start the Rugby in Manual
Mode:
Press and hold the Power Button for 5 seconds to change to Manual Mode.
• The Rugby will beep 5 times while holding the Power Button.
• After releasing the button, the Rugby levels. The levelling LED flashes
green, then turns solid green for a few seconds.
• After levelling, the levelling LED turns red and the Rugby is in Manual
Mode.
6.
Attach the receiver to a rod.
7.
Turn on the receiver.
8.
At the base of the slope, adjust the height of the receiver on the rod until
the on-grade (centre-line) position is indicated on the receiver by:
• the centre bar
• the green flashing LED
• a solid audio tone
9.
The desired slope can be set with the slope adapter.
The receiver can now be used to control the grade of the slope.
5 s
5
7
3a
3b
4
790434 - A240
Slope adapter
1% = 0.6°
2% = 1.1°
3% = 1.7°
5% = 2.9°
10% = 5.7°
20% = 11.3°
30% = 16.7°
100% = 45.0°
9
005768_001
8
1 + 2
6
X
α
α
Содержание Rugby 610
Страница 1: ...Leica Rugby 610 User Manual Version 1 0 English ...
Страница 43: ...Rugby 610 Index 43 ...