![Leica Geosystems DD120 Series Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/leica-geosystems/dd120-series/dd120-series_user-manual_1873523033.webp)
2.
Both persons:
Start walking parallel to each other, cir-
cling the target area.
☞
The tracing signal is induced
directly onto the utility and
indicated on the locator.
0016805_001
3.
In the presence of a detectable utility,
the locator emits a tone and the signal
strength indicators rise and fall as you
pass over the utility.
Return to the position where the Locate
screen shows a peak reading. Mark the
position of a utility with marker paint,
pegs, flags or something similar.
☞
Never drive pegs into the
ground over the utility!
☞
To trace a specific utility, use
the pinpointing and tracing
methods. Refer to "5.1 How
to Pinpoint a Utility" and "5.2
500
0016806_001
☞
Pinpoint and trace utilities until you are
satisfied that the area has been ade-
quately tested.
0016807_001
5.5
Using the Transmitter in Connection Mode
5.5.1
General Information
Connection mode is the most efficient way to apply a signal to a utility. The
cable set of the transmitter or any of the available accessories are connected
to the utility which is to be traced or identified.
☞
Whenever possible, use the transmitter in connection mode, espe-
cially for taking a depth reading.
☞
The Numeric Peak Indicator can be used to indicate multiple utilities
or to assist tracing. The utility with the maximum value is typically the
one connected to.
☞
The black connection cable can be connected to other metallic struc-
tures which go into the ground, such as iron grids or metal covers of
access chambers.
☞
In dry conditions it may be necessary to add water around the earth
point to get a good connection.
☞
When using the connection cable set, examine the connection points
and remove contamination if a continuous audible output is not ach-
ieved.
Connection mode
Applications
33