USER HANDBOOK
for stairlift type OMEGA
Edition Jan. 2004
Omega
platform lift
page 21 of 25
Case 2
The occupied platform is not close to a stop position.
Notice:
Position of the hand lever for break release and the hand wheel is explained on page 9.
The describtion of the main power switch is on page 10.
For the rescue of the passenger
two persons
are needed! If there is only one person
available, it is necessary to wind the carriage into the next station
(see case 1).
1. Turn off the main power switch.
2. Take the hand wheel and insert it into the hole located at the back of the motor.
3. Tighten the hand lever for break release and turn the hand wheel until reaching the next
half-landing or straight part of the staircase (see Illustration 1.1). Do not stop at a curved
area of the rail!
4.
Emergency unclamping of the barrier
: In order to open the barrier when not in a station,
please carry out the following instructions. It is only permitted to open the barrier up to the
stairs (see page 20). Otherwise one could face the danger of falling or rolling down.
5. The wheelchair driver can now be lifted down from the platform (see Illustration 2.1).
6. If using a manual platform, close the platform as usual. That means: First close the barriere
and then fold up the platform!
7. If using an automatic platform, first fold down the barrier to the closed position (see
Illustration 3).
Now the platform can be closed without any problem (see Illustration
4.1). The platform must be locked with the padlock on the carriage.
8. Call your service team!
Ill. 1.1
Ill. 2.1
Ill. 3.1
Ill. 4.1