Poollift Delphin page 9
5. Operating
The operating lever on the entry level as well as on the exit level (in the
water) ensures that the access and the exit is possible without any further help
by another person.
The movement direction is controlled by the 3-way-valve. To go upwards you
have to pull the operating lever down and if you want to go downwards you
have pull the operating lever up. Particular parts are shown in the attachment
„Mechanical scheme“.
6. Diagnostics
Poollift holders can check their installation for flaws on their own accord with the help of the
following points. Apart from that they can contact the service company if malfunctions occur.
By no means it is allowed to manipulate, change or remove any components of the installation.
The Poollift does not move (or too slow) upwards?
Check:
•
The pressure water supply must be opened and the pressure water hose must be flawless
•
The valve must be in the end position (turned down)
•
Appropriate water pressure is necessary.
•
There must not be any defect on the seal of the cylinder
The Poollift does not move (or too slow) downwards?
Check:
•
The drain hose must be in good condition.
•
The valve must be in the end position (turned up)
•
There must not be any defect on the seal of the cylinder
7. Cleansing and Maintenance
The Poollift is very easy to clean. The installation has to be cleaned from eventual organic and
inorganic sediments regularly. Appropriate care ensures a problem-free operation over the long term.
Please check all screw connections regularly and tighten loose screws.
The Poollift uses drinking water as a lubricant, that is why it is not necessary to lubricate the
installation.
Picture 1: 3-way-valve