background image

BD

A Cap

tur

a 100 MIF

ARE® / 22020-06-29 (GB)

3

FACTORY SETTINGS

The lock can be closed and opened at this point of time with one or more installation cards. After a Master card has 
been programmed, the lock is in the operating mode “assigned use“ and the installation card cannot be used any 
more.

CARE AND MAINTENANCE

U

U

Do not spill any liquid over or into the individual components of the lock, and never immerse the components in 
any liquid.

U

U

The product should not be exposed to direct sunlight.

U

U

Clean the lock and the components with a clean, soft, damp cloth only.

U

U

Do not use any cleaning agents containing abrasives or solvents, as these may damage the housing.

U

U

Treating any of the electronic and mechanical components improperly or in any way other than described in 
these operating instructions may lead to malfunctions and the loss of warranty.

U

U

Change the battery in good time. At the latest, when the lock issues corresponding battery warnings.

FUNCTIONAL DESCRIPTION

With the Captura 100 MIFARE® lock, you can conveniently lock and unlock your furniture. Non-contact RFID techno-
logy based on 13.56 MHz is used as the “key“. Two operating modes are available:

Operating mode

Description

Assigned use

There is a fixed assignment between the transponder cards and the locks. The user cards are 
programmed or deactivated at the lock by means of a master card. The system thus allows 
the granting of selective access authority for an item of furniture (e.g. cabinet), so that 
only authorised persons with a transponder card have access. A transponder card can be 
programmed simultaneously on multiple locks with “Assigned use“ operating mode. Up to 250 
different transponder cards can be programmed per lock.  

Shared use

With the user card, a user can use a free lock / storage of his choice. It is not possible to 
program the user card using the master card. If a lock is closed with the user card, the user card
and the lock are coupled to each other. The card cannot be used at any other lock in “shared 
use“ mode, and the lock will not accept any other user card. This coupling is only deactivated 
when the user opens the lock again with his user card. The card can now be used for another 
lock.

U

U

The battery must not be charged!

U

U

Keep the product away from children, as small parts may be swallowed!

U

U

Any persons swallowing batteries must seek immediate medical advice!

U

U

Damaged and/or leaking batteries may cause acid burns and/or poisoning!

Please note that the distance 
between two or more locks 
with an inserted battery must 
be at least 10 cm (lateral 
distance) and 15 cm (frontal 
distance) during storage, 
transport and operation.

>10 cm

>15 cm

Содержание Captura 100 MIFARE

Страница 1: ...ogramming the Master card 11 Programming the Master card Closing and Opening 12 Unauthorised Transponders cards Facility Manager Function Emergency Opening 13 Deleting Individual Transponder Cards Deleting All Transponder Cards 14 Changing Operating Mode 15 Deactivating and activating acoustic signals Resetting to factory settings 16 Activation and deactivation of automatic locking 17 Battery warn...

Страница 2: ...ng cards or with the LEHMANN Management Software LMS These operating instructions describe how to use the locking system with master and programming cards The software LMS and the corresponding documents can be found at https lms lehmann locks com SAFETY PRECAUTIONS U U Pack the battery for the transport of the lock so that no short circuit can occur risk of explosion and fire U U When replacing t...

Страница 3: ... fixed assignment between the transponder cards and the locks The user cards are programmed or deactivated at the lock by means of a master card The system thus allows the granting of selective access authority for an item of furniture e g cabinet so that only authorised persons with a transponder card have access A transponder card can be programmed simultaneously on multiple locks with Assigned ...

Страница 4: ...e of an installation card is optional Master card For complete commissioning a master card must be programmed for both operating modes The master card is required for starting and terminating programming operations This also includes the programming of user cards in Assigned use mode The master card also enables the so called Facili ty Manager function and the emergency opening of the lock A maxim...

Страница 5: ... 10 Lightpoint only optional 1 2 3 4 5 6 7 8 9 Door Sidewall DIMENSIONS Lock Captura All dimensions in mm SYSTEM COMPONENTS AND PACKAGE CONTENTS Please note that these operating instructions apply to different product versions The package content therefore depends on the respective product variant The product variants and mounting recommendations shown here are intended for wooden furniture with a...

Страница 6: ...1 48 8 7 2 26 38 3 8 Front cover C1 for metallic surfaces All dimensions in mm 70 0 7 6 5 8 8 3 3 5 5 54 4 5 70 0 7 6 5 8 8 3 3 5 5 54 4 5 70 0 7 6 5 8 8 3 3 5 5 54 4 5 Locking pin unit SD Type A with ejector pin A1 52 0 2 5 2 5 3 1 0 4 5 4 2 5 4 3 0 3 8 5 7 1 1 2 20 3 7 19 3 7 65 7 5 5 2 1 52 0 2 5 2 5 3 1 0 4 5 4 2 5 4 3 0 3 8 5 7 1 1 2 20 3 7 19 3 7 65 7 5 5 2 1 The ejector pin A1 can only be i...

Страница 7: ...s must be checked on a project basis 4 5 54 10 7 2 3 2 0 2 3 5 58 48 4 5 54 10 7 2 3 2 0 2 3 5 58 48 For an adequate fine adjustment of the locking pin an average dimension of 53 mm is recommended MOUNTING ON NON METAL SURFACES Mounting the lock with locking pin SD Type A e g for hinge doors Side wall Inside of the door Side wall Door Lightpoint O16 for material thickness of 16 21 mm Lightpoint O1...

Страница 8: ... with locking pin SD Type B e g drawer All dimensions in mm Note that the lightpoint can be installed as an option Without a lightpoint only acoustic signaling is available Mounting the lightpoint C 3 1 7 1 4 5 54 27 Top Shelf inside view To be installed without tools ...

Страница 9: ... i n r o d ß e i l h c S d n u a g e m 13 5 Door Implied screw on socket Center point for locking pin Required hole punch in the door Hole punch in the door Side wall with locking pin SD Type A 13 5 5 2 4x Thermoplastic screw 3x25 ATTENTION If no lightpoint is installed a sticker is recommended on the outside of the door centered behind the lock for correct positioning of the RFID transponder Usin...

Страница 10: ...ng the lock in the furniture Inserting the battery Battery is inserted correctly in the battery compartment Optical signals Quick flashing Short flashing Long flashing Acoustic signals Short Long The RFID antenna is located on the back of the lock Always place the transponder straight and centered on the lock TIPS FOR THE FOLLOWING PROGRAMMING STEPS The last 5 seconds before the shutdown of the pr...

Страница 11: ... master card for the first time Hold the master card in front of the lock PROGRAMMING THE MASTER CARD Irrespective of the desired operating mode a master card must always be programmed before further programming and operation Only one master card can be programmed per lock The programming of the master card can be carried out when the lock is closed as well as when it is open If the lock is closed...

Страница 12: ...rst programming the user cards see Closing and Opening see below After programming the user cards can open and close the lock Programming user cards Hold the master card in front of the lock Hold the user card in front of the lock The card is accepted and programmed This process can be repeated to program multiple user cards Card is not accepted Hold the master card in front of the lock CLOSING AN...

Страница 13: ... then closes automatically After this automatic closure authorised user cards can continue to be used in shared use mode as well as in assigned use mode The last 5 seconds before closing are indicated by optical and acoustic signals EMERGENCY OPENING In the event that one or all authorised user cards are currently not available an emergency opening can be effected with the master card Please note ...

Страница 14: ...individual user cards Hold the master card in front of the lock Hold the user card to be deleted in front of the lock Hold the master card in front of the lock DELETING ALL TRANSPONDER CARDS only for assigned use mode The deleting process can only be carried out when the lock is open Should there be no authorised user card to hand first perform an emergency opening using the master card Deleting a...

Страница 15: ...ming card set must be bought separately from LEHMANN Vertriebsgesellschaft mbH Co KG The cards are for universal use Changing the operating mode Hold the master card in front of the lock Hold the programming card P1 Mode in front of the lock Shared use mode is selected Shared use Hold the programming card P1 Mode in front of the lock again Assigned use mode is selected Assigned use Hold the master...

Страница 16: ... RFID reader with the LED is mounted outside the item of furniture Otherwise neither visual nor acoustic signals are passed on to the users making programming and possibly also operation difficult Please note that the acoustic signals for the battery warning and for changing the operating mode cannot be deactivated The programming card set must be bought separately from LEHMANN Vertriebsgesellscha...

Страница 17: ... function is activated the lock closes automatically after 5 seconds after opening the lock with an authorized transponder It is recommended to activate automatic locking after programming the transponders The function can be carried out by using the master card and the programming card P4 Auto Locking To do this the lock must be in the mode assigned use and in an open position If the operating mo...

Страница 18: ...battery replacement in the event of reduced battery power The battery warning takes place in two phases The settings are saved even without a power supply e g in case of battery replacement or in case the battery should be completely empty Battery replacement should be carried out within 2 minutes Battery warning Phase 1 Before an action can be carried out closing opening programming a battery war...

Страница 19: ...on the website www lehmann locks com if required e g for technical reasons You will receive further information on the implementation and installation together with the firmware update DISPOSAL Dispose the locking system in accordance with local regulations and guidelines Remove the battery and dispose them separately in accordance with the national regulations When disposing of partially discharg...

Страница 20: ... MIFARE 22020 06 29 GB 20 LEHMANN Vertriebsgesellschaft mbH Co KG Postfach 26 20 D 32383 Minden Fon 49 571 50 599 0 Fax 49 571 50 599 822 info lehmann locks com www lehmann locks com DIN EN ISO 9001 2015 zertifiziert ...

Отзывы: