Time Delay

The time delay can be selected by the user during set up. It can be adjusted 
from 15 seconds up to 30 minutes. For additional information on how to adjust 
it, please read the SENSOR ADJUSTMENT & PROGRAMMING section of this 
installation manual.

Light Level

When the sensor is set for occupancy sensor Mode 
2 (Auto-ON/OFF) the light level feature prevents 
the sensor from automatically turning the lights 
ON if there is already enough light in the area. To 
adjust the light level, please read the SENSOR 
ADJUSTMENT & PROGRAMMING section of this 
installation manual.

Coverage Area

The RS-250-N has a maximum range of 180 degrees 
and a coverage area of 600 sq. feet (56 sq. meters). 
The sensor must have a clear and unobstructed 
view of the coverage area. Objects blocking the 
sensor’s lens may prevent detection thereby 
causing the light to turn OFF even though 
someone is in the area.

Windows, glass doors, and other transparent barriers will obstruct 

the sensor’s view and prevent detection.

INSTALLATION & WIRING

WARNING

Disconnect power to the wall switch box by turning OFF 

the circuit breaker or removing the fuse for the circuit before installing 

the RS-250-N, replacing lamps, or doing any electrical work.

1.  Prepare the switch box.

 

After the power is turned OFF at the circuit 
breaker box, remove the existing wall plate and 
mounting screws. Pull the old switch out from the 
wall box.

2.  Identify the type of circuit.

 

In a Single Pole Circuit (see Fig. 2), two single 
wires connect to two screws on the existing 
switch. A ground wire may also be present and 
connected to a ground terminal on the old switch. 
A neutral wire should also be present in the wall 
box.

CAUTION - FOR YOUR SAFETY: 

Connecting a proper ground to the 

sensor provides protection against electrical shock in the event of 

certain fault conditions. If a proper ground is not available, consult 

with a qualifi ed electrician before continuing installation.

 

Only connect the RS-250-N to a Single Pole Circuit. The RS-250-N is not 
suitable for 3-way switching. If the existing wiring does not match the 
description for a Single Pole Circuit, you should consult with a qualifi ed 
electrician.

3.  Prepare the Wires.

 

Tag the wires connected to the existing switch, so 
that they can be identifi ed later. Disconnect the 
wires. Make sure the insulation is stripped off the 
wires to expose their copper cores to the length 
indicated by the “Strip Gage,” (in Fig. 3) (approx. 
1/2 inch).

www.wattstopper.com/athome

Ground

HOT (power from

circuit box)

LOAD

(power 

to lamp)

NEUTRAL

Fig. 2: Typical Single 

Pole Switch 
Wiring

Strip Gage

1/2"

12.7 mm

Fig. 3: Wire 

Stripping

25'

(7.6m)

12'

(3.7m)

Fig. 1: Sensor Coverage Area

Содержание WattStopper RS-250-N

Страница 1: ...r Manual ON OFF Auto OFF The user must press the ON OFF button to turn the load ON The RS 250 N keeps the load ON until no motion is detected for the selected time delay period adjustable from 15 seco...

Страница 2: ...e the switch box After the power is turned OFF at the circuit breaker box remove the existing wall plate and mounting screws Pull the old switch out from the wall box 2 Identify the type of circuit In...

Страница 3: ...button Slide the button downward approximately 1 2 inch to expose the mode button and adjustment trimpots Setting up the Operating Mode Select the operating mode by pressing the Mode button The night...

Страница 4: ...led load turns OFF after 5 seconds if no motion is detected 3 Move into the coverage area The controlled load turns ON for 5 seconds each time the sensor detects motion After 5 seconds expire without...

Страница 5: ...on the part of Watt Stopper Legrand for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property rev...

Страница 6: ...encuentra encendida Cuando por el contrario la carga controlada se encuentra encendida la Luz Nocturna se encuentra apagada Modos de Operaci n Es posible elegir entre dos modos de operaci n durante l...

Страница 7: ...e exista detecci n INSTALACION Y CABLEADO ADVERTENCIA Desconecte la corriente que alimenta la caja de conexiones apagando el disyuntor breaker o removiendo el fusible para el circuito correspondiente...

Страница 8: ...ENCENDIDO APAGADO por ambos extremos y desl celo hacia abajo aproximadamente 1 2 pulgada de tal forma que el Bot n de Selecci n de Modos y las Perillas de Ajuste queden expuestas Selecci n del Modo de...

Страница 9: ...n de ocupaci n si la cantidad de luz natural es mayor a la existente actualmente 6 Reajuste el tiempo de retardo de apagado al valor deseado Advertencia No sobregire la perilla de ajuste del Nivel de...

Страница 10: ...apaga autom ticamente Presione el bot n de ENCENDIDO APAGADO Si la carga se apaga prosiga con el siguiente paso El tiempo del retardo de apagado puede ser con gurado desde 30 segundos hasta 30 minutos...

Отзывы: